[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-alarm-evacuation-106-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"警報與避難系統消防安全設備概要","alarm-evacuation",106,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"火警探測線路之配線，依現行規定須要何種等級的防護措施？如果採用穿套金屬管或外覆足夠厚度的混凝土保護，有何影響？試申論之。（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"醫療院所重症病房空間，依法應設何種避難器具？有何可減免設置的作法建議，試申論之。（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"警報與避難系統","警報與避難 · Alarm & Egress","探測器、受信總機、緊急廣播,加上標示設備、緊急照明與避難器具——條號最零碎,也最吃「表格記憶」。","警報系統抓火警分區劃定原則、各型探測器(差動式局限型\u002F分布型、定溫式、偵煙式)的裝置場所與高度限制、受信總機與緊急電源;避難系統抓出口\u002F避難方向指示燈的設置與有效範圍、緊急照明照度、緩降機與避難器具的設置數量與開口面規定。條文以表格呈現者多,建議整理成對照表背。",[23,28,32,37,42,46,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-001","某一 KTV 視聽歌唱場所設於大樓地下層，依規定樓地板面積如合計超過多少，應設置瓦斯漏氣火警自動警報設備？","C",true,{"webId":29,"number":15,"stem":30,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-002","對於消防安全設備緊急供電系統之配線之規定，下列何者正確？","B",{"webId":33,"number":34,"stem":35,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-003",3,"裝設緊急廣播設備之建築物之規定，下列何者錯誤？","D",{"webId":38,"number":39,"stem":40,"answer":41,"indexable":27},"fire-106-1-alarm-evacuation-004",4,"依各類場所消防安全設備檢修及申報作業基準規定，1 種光電式局限型偵煙探測器於使用加煙試驗器確認動作之時間，加煙後至動…","A",{"webId":43,"number":44,"stem":45,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-005",5,"依各類場所消防安全設備設置標準規定，下列何種場所如設置高感度密閉式撒水頭自動撒水設備，得免設火警自動警報設備？",{"webId":47,"number":48,"stem":49,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-006",6,"樓梯、斜坡通道、昇降機之昇降路及管道間等場所，其頂層相差在二層以下、水平距離多少範圍內，視為一火警分區？",{"webId":51,"number":52,"stem":53,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-007",7,"如設置救助袋做為避難器具，下列敘述何者錯誤？",{"webId":55,"number":56,"stem":57,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-008",8,"天花板設排氣口或回風口時，偵煙式探測器應裝置於排氣口或回風口周圍多少距離範圍內？",{"webId":59,"number":60,"stem":61,"answer":41,"indexable":27},"fire-106-1-alarm-evacuation-009",9,"差動式分布型探測器為熱電偶式時，熱電偶應裝置在裝置面下方多少公分範圍內？",{"webId":63,"number":64,"stem":65,"answer":41,"indexable":27},"fire-106-1-alarm-evacuation-010",10,"緩降機設置周圍為避免有操作障礙，因此限制必要操作面積為 M 平方公尺以上（不含避難器具所占面積），但邊長應為 N 公…",{"webId":67,"number":68,"stem":69,"answer":41,"indexable":27},"fire-106-1-alarm-evacuation-011",11,"Ｐ型受信總機採用數個分區共用一公用線方式配線時，該公用線供應之分區數，不得超過 X 個。受信總機之探測器回路電阻，應…",{"webId":71,"number":72,"stem":73,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-012",12,"依據緊急照明燈認可基準進行充電試驗時，蓄電池電壓降達額定電壓多少以內時，需能自動充電？",{"webId":75,"number":76,"stem":77,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-013",13,"集合住宅計算收容人數以設置避難器具時，每戶收容人數以多少人計算？",{"webId":79,"number":80,"stem":81,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-014",14,"依各類場所消防安全設備檢修及申報作業基準規定，火警自動警報設備之受信總機前應確保多少公尺以上空間以進行檢查及操作使用…",{"webId":83,"number":84,"stem":85,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-015",15,"依緩降機認可基準規定，緩降機之最大使用載重，應在最大使用人數乘以 W 所得數值以上。下述 W 值何者正確？",{"webId":87,"number":88,"stem":89,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-016",16,"瓦斯漏氣火警自動警報設備裝置於瓦斯對空氣之比重未滿一之建築物室內時，檢知器設置位置應距瓦斯燃燒器具或瓦斯導管貫穿牆壁…",{"webId":91,"number":92,"stem":93,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-017",17,"檢查緩降機性能時，有關常溫下降試驗之判定中，緩降機最大下降速度應在多少以內？",{"webId":95,"number":96,"stem":97,"answer":41,"indexable":27},"fire-106-1-alarm-evacuation-018",18,"依各類場所消防安全設備檢修及申報作業基準規定，火焰探測器以動作試驗器確認探測器之動作應在多少時間內方為合格？",{"webId":99,"number":100,"stem":101,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-019",19,"一居室設置於地上層，該樓層亦非為無開口樓層，自內部任一點易於識別主要出入口，主要出入口之步行距離在多少以下者，得免設…",{"webId":103,"number":104,"stem":105,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-020",20,"差動式探測器之動作原理為感應火場中何種參數？",{"webId":107,"number":108,"stem":109,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-021",21,"下列消防安全設備緊急供電系統之配線，何者需施予耐燃保護？",{"webId":111,"number":112,"stem":113,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-022",22,"依出口標示燈及避難方向指示燈認可基準規定，燈具附有起動器者，應在多少時間內點燈？",{"webId":115,"number":116,"stem":117,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-023",23,"一大樓內部某樓層設有不得供避難、通行及搬運以外用途之防火構造架空走廊一座，該樓層可依法減設多少具避難器具？",{"webId":119,"number":120,"stem":121,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-024",24,"依各類場所消防安全設備設置標準規定，特別安全梯或緊急昇降機間排煙室之排煙設備設置排煙、進風風管時，下列何者有誤？",{"webId":123,"number":12,"stem":124,"answer":41,"indexable":27},"fire-106-1-alarm-evacuation-025","依緊急照明燈認可基準規定，內置電池型緊急電源供電照明時間應維持 1.5 小時以上（供緊急照明燈總數）後，其蓄電池電壓…",{"webId":126,"number":127,"stem":128,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-026",26,"樓梯或斜坡通道以外之場所，廣播區域之殘響時間在 3 秒以上時，揚聲器之裝設需符合 r = 3 \u002F 4 QSα\u002Fπ (…",{"webId":130,"number":131,"stem":132,"answer":41,"indexable":27},"fire-106-1-alarm-evacuation-027",27,"避難方向指示燈設於樓梯或坡道者，在樓梯級面或坡道表面之照度，應在多少勒克司（lx）以上？",{"webId":134,"number":135,"stem":136,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-028",28,"大型建築物警報設備使用許多中繼器來連結探測器與受信總機，但下列何者不是警報設備中繼器主要功能？",{"webId":138,"number":139,"stem":140,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-029",29,"瓦斯濃度達到警報濃度值後，其濃度仍繼續存在，即發出警報，但瓦斯洩漏濃度越高，則警報延遲動作時間越短，此種檢知瓦斯之警…",{"webId":142,"number":143,"stem":144,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-030",30,"在某飯店檢查瓦斯漏氣火警自動警報設備時，何項試驗必須切換成緊急電源之狀態？",{"webId":146,"number":147,"stem":148,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-031",31,"在某飯店檢查瓦斯漏氣火警自動警報設備，進行檢知器之性能檢查時，發現同一個檢知回路上裝設有 18 個瓦斯漏氣檢知器，至…",{"webId":150,"number":151,"stem":152,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-032",32,"針對瓦斯漏氣火警自動警報設備進行性能檢查，使用噪音計進行瓦斯漏氣檢知區域警報裝置之音量檢測時，距離警報裝置 1 公尺…",{"webId":154,"number":155,"stem":156,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-033",33,"針對某百貨公司美食街進行檢修，下列何項試驗必須使用加瓦斯試驗器，使兩個回路之任一檢知器（各回路一個）同時動作，以確認…",{"webId":158,"number":159,"stem":160,"answer":41,"indexable":27},"fire-106-1-alarm-evacuation-034",34,"在裝設定溫式感知線型探測器場所，進行回路合成阻抗試驗時，會使用下列何種檢查儀器？",{"webId":162,"number":163,"stem":164,"answer":31,"indexable":27},"fire-106-1-alarm-evacuation-035",35,"執行檢修時，在室溫 15℃狀態下，使用加熱試驗器進行差動式局限型第二種探測器之性能檢查時，其動作時間應在多少秒內方為…",{"webId":166,"number":167,"stem":168,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-036",36,"很多工程裝設局限型探測器時多緊鄰天花板上出風口，造成失效或延遲警報，因此，施工時依規定裝設位置應距該出風口多少公尺以…",{"webId":170,"number":171,"stem":172,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-037",37,"為避免探測死角，在安裝光電式分離型探測器時，其受光器及送光器應設在距其背部牆壁多少公分範圍內？",{"webId":174,"number":175,"stem":176,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-038",38,"依各類場所消防安全設備設置標準規定，避難指標設於出入口裝設應距樓地板面的高度要求為多少？",{"webId":178,"number":179,"stem":180,"answer":26,"indexable":27},"fire-106-1-alarm-evacuation-039",39,"具有效採光，且直接面向室外之通道或走廊居室得免設緊急照明；所謂有效採光面積應達該居室樓地板面積多少比率方得免設？",{"webId":182,"number":183,"stem":184,"answer":36,"indexable":27},"fire-106-1-alarm-evacuation-040",40,"有關出口標示燈具閃滅或音聲引導功能者，依規定下列何者錯誤？",50,1785123168683]