[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-alarm-evacuation-108-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"警報與避難系統消防安全設備概要","alarm-evacuation",108,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"近來某工業區生產芳香烴的工廠發生爆炸意外，幾公里以外都能看到大量濃煙及大火，致石化廠安全管理議題再度被社會大眾重視，依據「各類場所消防安全設備設置標準」規定，請詳述該類公共危險物品製造場所符合那些條件時，應設置火警自動警報設備及緊急通報裝置？石化工業等製造場所使用傳統探測器容易誤報，而使得昂貴的自動滅火系統產生不必要的釋放或因疏忽、故障、遲報等導致火災的蔓延擴大，何種類探測警報系統可增加系統可靠的偵測效果及準確度，期能將災害損失減到最低，並請說明其動作原理為何？（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"高層建築物之緊急昇降機間為消防人員搶救時重要路徑之一，不得遭受到濃煙的危害。機間內設置排煙室若採用機械排煙設備，請說明其主要組成構件並繪出其昇位圖例。依據「各類場所消防安全設備設置標準」規定，請試述在煙控設計原則及排煙機檢修作業中「性能檢查」之檢查方法、判定方法與注意事項。（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"警報與避難系統","警報與避難 · Alarm & Egress","探測器、受信總機、緊急廣播,加上標示設備、緊急照明與避難器具——條號最零碎,也最吃「表格記憶」。","警報系統抓火警分區劃定原則、各型探測器(差動式局限型\u002F分布型、定溫式、偵煙式)的裝置場所與高度限制、受信總機與緊急電源;避難系統抓出口\u002F避難方向指示燈的設置與有效範圍、緊急照明照度、緩降機與避難器具的設置數量與開口面規定。條文以表格呈現者多,建議整理成對照表背。",[23,28,32,37,41,46,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-108-1-alarm-evacuation-001","某一新建建築物地面六層、地下二層，用途為辦公室，每層樓地板面積為 400 平方公尺，設置火警自動警報系統，假設 1 …","C",true,{"webId":29,"number":15,"stem":30,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-002","特別安全梯的安全梯與緊急昇降機兼用時，其排煙機、進風機之排煙量、進風量須在每秒多少立方公尺以上？","A",{"webId":33,"number":34,"stem":35,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-003",3,"用途為補習班，居室樓地板面積 300 平方公尺，採用有效通風方式檢討，其排煙口設於天花板下方 80 公分內，試問有效…","D",{"webId":38,"number":39,"stem":40,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-004",4,"某一防火構造建築物，地上 5 層且為無開口樓層，1 至 2 層供辦公室用途使用，3 至 5 層供餐廳用途使用，各樓層…",{"webId":42,"number":43,"stem":44,"answer":45,"indexable":27},"fire-108-1-alarm-evacuation-005",5,"瓦斯漏氣火警自動警報設備進行性能檢查，下列敘述何者正確？","B",{"webId":47,"number":48,"stem":49,"answer":26,"indexable":27},"fire-108-1-alarm-evacuation-006",6,"探測器應依裝置場所高度選擇探測器種類裝設，下列何者錯誤？",{"webId":51,"number":52,"stem":53,"answer":45,"indexable":27},"fire-108-1-alarm-evacuation-007",7,"有關無線電通信輔助設備設置規定，下列何者正確？",{"webId":55,"number":56,"stem":57,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-008",8,"感熱式局限型探測器使用加熱試驗器對探測器加熱，依動作時間方法判斷，下列何者符合動作時間之規定？（標稱動作溫度與周圍溫…",{"webId":59,"number":60,"stem":61,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-009",9,"緩降機固定架或支固器具使用錨定螺栓固定時，選用螺紋標稱為 M12×1.75 之螺栓，試問其螺栓埋入混凝土內不含灰漿部…",{"webId":63,"number":64,"stem":65,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-010",10,"某一廣播區域面積為 150 平方公尺，設有揚聲器，請問距所設揚聲器 1 m 處所測得之音壓須達多少以上才符合規定？",{"webId":67,"number":68,"stem":69,"answer":45,"indexable":27},"fire-108-1-alarm-evacuation-011",11,"為提升火災發生時之通報效率，並避免延誤報案致生重大火災事故，各類場所消防安全設備設置標準於 107 年 10 月 1…",{"webId":71,"number":72,"stem":73,"answer":45,"indexable":27},"fire-108-1-alarm-evacuation-012",12,"有關依各類場所消防安全設備設置標準規定設置之耐燃保護、耐熱保護措施，室內消防栓、室外消防栓、自動撒水、水霧、泡沫、乾…",{"webId":75,"number":76,"stem":77,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-013",13,"有關避難器具之外觀試驗，下列何者不屬於外觀試驗？",{"webId":79,"number":80,"stem":81,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-014",14,"緊急照明設備性能試驗之水平面照度測試，切換為緊急電源狀態亮燈，經過 A 分鐘後，使用 B 測試，確認緊急照明燈之照度…",{"webId":83,"number":84,"stem":85,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-015",15,"依建築技術規則對緊急用昇降機之相關規定，下列何者正確？",{"webId":87,"number":88,"stem":89,"answer":26,"indexable":27},"fire-108-1-alarm-evacuation-016",16,"依照各類場所消防安全設備檢修及申報作業基準之規定，某燃燒器具的瓦斯，對空氣比重大於 1 時，其檢知器應設於距瓦斯燃燒…",{"webId":91,"number":92,"stem":93,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-017",17,"某商場有一樓層，以防煙垂壁區劃為四區，各區劃樓地板面積分別為 100 平方公尺、300 平方公尺、250 平方公尺、…",{"webId":95,"number":96,"stem":97,"answer":26,"indexable":27},"fire-108-1-alarm-evacuation-018",18,"利用加瓦斯試驗器對瓦斯漏氣檢知器進行檢測，其性能判定方法下列何者錯誤？",{"webId":99,"number":100,"stem":101,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-019",19,"應設排煙設備場所之樑為裸露式者，交錯之樑形成之各防煙區劃皆應設置排煙口。但其樓地板面積每 500 平方公尺防煙區劃內…",{"webId":103,"number":104,"stem":105,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-020",20,"依消防法令規定，觀光旅館、飯店、旅館、招待所（限有寢室客房者）等場所，採膠囊式經營時，須設置火警自動警報設備者，下列…",{"webId":107,"number":108,"stem":109,"answer":26,"indexable":27},"fire-108-1-alarm-evacuation-021",21,"依各類場所消防安全設備設置標準規定，下列危險物品場所何者不須設置火警自動警報設備？",{"webId":111,"number":112,"stem":113,"answer":45,"indexable":27},"fire-108-1-alarm-evacuation-022",22,"依照各類場所消防安全設備檢修及申報作業基準之規定，會結露之場所適用的探測器為下列何者？",{"webId":115,"number":116,"stem":117,"answer":45,"indexable":27},"fire-108-1-alarm-evacuation-023",23,"偵煙式局限型探測器裝設於防火構造建築物天花板高度 8 公尺之裝置面時，若樓地板面積為 500 平方公尺，且其天花板中…",{"webId":119,"number":120,"stem":121,"answer":45,"indexable":27},"fire-108-1-alarm-evacuation-024",24,"某防火構造建築物，供三溫暖洗澡區使用，面積為 130 m2，天花板高度為 3.6 m，請問下列何者為適當的探測器？",{"webId":123,"number":12,"stem":124,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-025","依各類場所消防安全設備設置標準規定，火警自動警報設備之火警發信機（非定址式）與 P 型受信總機，其配線為何種配線？",{"webId":126,"number":127,"stem":128,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-026",26,"依各類場所消防安全設備設置標準規定，裝置面高度 10 公尺者，不可選擇下列何種探測器設置？",{"webId":130,"number":131,"stem":132,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-027",27,"依各類場所消防安全設備設置標準第 112 條，有關火警自動警報設備之火警分區劃定規定，下列何者錯誤？",{"webId":134,"number":135,"stem":136,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-028",28,"有關緊急廣播設備之敘述，下列何者錯誤？",{"webId":138,"number":139,"stem":140,"answer":45,"indexable":27},"fire-108-1-alarm-evacuation-029",29,"消防安全設備測試報告書測試方法及判定要領中規定，火警自動警報設備外觀試驗，其定溫式感知線型探測器之判定要領中，下列何…",{"webId":142,"number":143,"stem":144,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-030",30,"利用各種減光罩對光電式分離型探測器進行測試，以確認其火災動作試驗、不作動試驗、故障警報試驗並判定是否符合規定，下列方…",{"webId":146,"number":147,"stem":148,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-031",31,"依各類場所消防安全設備設置標準對於出口標示燈設置之相關規定，下列何者正確？",{"webId":150,"number":151,"stem":152,"answer":26,"indexable":27},"fire-108-1-alarm-evacuation-032",32,"下列出口標示燈及避難方向指示燈之緊急電源描述何者正確？",{"webId":154,"number":155,"stem":156,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-033",33,"有關 B 級出口標示燈（顯示避難方向符號者）及 B 級避難方向指示燈有效範圍的規定，下列何者正確？",{"webId":158,"number":159,"stem":160,"answer":26,"indexable":27},"fire-108-1-alarm-evacuation-034",34,"依各類場所消防安全設備設置標準之規定，下列何種避難器具的開口面積應為高 60 公分以上，寬 60 公分以上？",{"webId":162,"number":163,"stem":164,"answer":26,"indexable":27},"fire-108-1-alarm-evacuation-035",35,"依各類場所消防安全設備設置標準規定，在應設排煙設備之場所，有關其排煙設備設置之描述，下列何者錯誤？",{"webId":166,"number":167,"stem":168,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-036",36,"依各類場所消防安全設備設置標準第 28 條應設置排煙設備之規定，下列何者錯誤？",{"webId":170,"number":171,"stem":172,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-037",37,"某機場候機室樓地板面積 300 m2，自然排煙設備其窗戶都在天花板或其下方 80 公分範圍內，共有 10 扇窗，採正…",{"webId":174,"number":175,"stem":176,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-038",38,"依各類場所消防安全設備設置標準規定，特別安全梯及緊急昇降機間兼用排煙室時排煙閘門面積為 4 m2，忽略溫度的影響，測…",{"webId":178,"number":179,"stem":180,"answer":31,"indexable":27},"fire-108-1-alarm-evacuation-039",39,"依各類場所消防安全設備設置標準規定，下列何種場所不須設置緊急電源插座？",{"webId":182,"number":183,"stem":184,"answer":36,"indexable":27},"fire-108-1-alarm-evacuation-040",40,"依各類場所消防安全設備設置標準規定，緊急供電系統之配線的保護下列何者錯誤？",50,1785123168654]