[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-alarm-evacuation-111-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"警報與避難系統消防安全設備概要","alarm-evacuation",111,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"依各類場所消防安全設備設置標準，請說明非內置蓄電池式之緊急照明設備的配線規定。依消防安全設備及必要檢修項目檢修基準之規定，緊急照明設備進行性能檢查時，照度及緊急電源之檢查方法及判定方法為何？（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"火警自動警報設備是偵測火災的重要設備，其功能之妥善攸關火災是否能及時被發現。依消防安全設備及必要檢修項目檢修基準，請說明火警自動警報設備在進行綜合檢查時，「同時動作」及「綜合檢查」之檢查方法及判定方法為何？（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"警報與避難系統","警報與避難 · Alarm & Egress","探測器、受信總機、緊急廣播,加上標示設備、緊急照明與避難器具——條號最零碎,也最吃「表格記憶」。","警報系統抓火警分區劃定原則、各型探測器(差動式局限型\u002F分布型、定溫式、偵煙式)的裝置場所與高度限制、受信總機與緊急電源;避難系統抓出口\u002F避難方向指示燈的設置與有效範圍、緊急照明照度、緩降機與避難器具的設置數量與開口面規定。條文以表格呈現者多,建議整理成對照表背。",[23,28,32,37,41,46,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-111-1-alarm-evacuation-001","依各類場所消防安全設備設置標準規定，公共危險物品室內儲存場所總樓地板面積在多少平方公尺以上者，應設置火警自動警報設備…","A",true,{"webId":29,"number":15,"stem":30,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-002","平時有人之公共危險物品製造、儲存或處理場所，若未達應設置火警自動警報設備之規定時，其儲存、處理公共危險物品數量達幾倍…","B",{"webId":33,"number":34,"stem":35,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-003",3,"下列場所何者依規定應設置火警自動警報設備？","D",{"webId":38,"number":39,"stem":40,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-004",4,"某建築物火警自動警報設備之鳴動方式依規定採分區鳴動，在分區鳴動經多少分鐘內或受信總機再接受火災信號時，應立即全區鳴動…",{"webId":42,"number":43,"stem":44,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-005",5,"玻璃工場、熔接作業場所等設有用火設備，其火焰外露之場所，在選擇探測器時，下列何者較為適用？","C",{"webId":47,"number":48,"stem":49,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-006",6,"探測器依其工作原理，下列探測器何者具有搜集環境變異之功能，並採數位通訊方式傳回總機，再由總機根據歷史紀錄來決定是否作…",{"webId":51,"number":52,"stem":53,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-007",7,"依消防安全設備及必要檢修項目檢修基準，差動式分布型空氣管式之火災動作或動作持續試驗，不動作或測定之時間超過範圍時，應…",{"webId":55,"number":56,"stem":57,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-008",8,"一場所設置定溫式局限型 1 種探測器（非再用型）共有 32 個，今進行動作試驗時，應抽取 X 個探測器以加熱試驗器加…",{"webId":59,"number":60,"stem":61,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-009",9,"一非防火構造建築物，某層高度 5.2 公尺供辦公室使用，其探測區域為 310 平方公尺，若裝設補償式局限型 1 種探…",{"webId":63,"number":64,"stem":65,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-010",10,"依各類場所消防安全設備設置標準規定，有關揚聲器在居室樓地板面積在 X 平方公尺以下，其它非居室部分樓地板面積在 Y …",{"webId":67,"number":68,"stem":69,"answer":26,"indexable":13},"fire-111-1-alarm-evacuation-011",11,"依各類場所消防安全設備設置標準規定，下列場所何者未強制要求設置 119 火災通報裝置？",{"webId":71,"number":72,"stem":73,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-012",12,"某餐廳廚房之瓦斯爐具使用天然氣作為燃料時，依法設有瓦斯漏氣火警自動警報設備，其瓦斯漏氣檢知器應設於距瓦斯爐具水平距離…",{"webId":75,"number":76,"stem":77,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-013",13,"設有避難器具之場所，進行外觀檢查時，下列判定方法何者正確？",{"webId":79,"number":80,"stem":81,"answer":26,"indexable":13},"fire-111-1-alarm-evacuation-014",14,"依各類場所消防安全設備設置標準規定，供失智照顧型長期照顧服務機構、老人福利機構（安養機構）、產後護理機構等避難弱勢場…",{"webId":83,"number":84,"stem":85,"answer":26,"indexable":13},"fire-111-1-alarm-evacuation-015",15,"依各類場所消防安全設備設置標準規定，為確保排煙設備動作時，不受空調等通風換氣裝置影響排煙效果，下列何項排煙設備元件動…",{"webId":87,"number":88,"stem":89,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-016",16,"依各類場所消防安全設備設置標準規定，下列何種場所得免設排煙設備？",{"webId":91,"number":92,"stem":93,"answer":26,"indexable":13},"fire-111-1-alarm-evacuation-017",17,"下列何者非各類場所消防安全設備設置標準明定應設置防災監控系統綜合操作裝置之場所？",{"webId":95,"number":96,"stem":97,"answer":26,"indexable":13},"fire-111-1-alarm-evacuation-018",18,"局限型偵煙探測器光電式的偵測原理若設計為散亂光式，其對火場中何種信號較不敏感？",{"webId":99,"number":100,"stem":101,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-019",19,"有關緊急照明燈的緊急電源及配線之規定，下列敘述何者正確？",{"webId":103,"number":104,"stem":105,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-020",20,"依消防安全設備及必要檢修項目檢修基準，實施緊急照明設備性能檢查，檢查數量下列之敘述何者正確？",{"webId":107,"number":108,"stem":109,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-021",21,"依各類場所消防安全設備設置標準規定，下列有關出口標示燈及避難方向指示燈之敘述，何者正確？",{"webId":111,"number":112,"stem":113,"answer":26,"indexable":13},"fire-111-1-alarm-evacuation-022",22,"避難器具安裝完成實施性能試驗，針對支固器具進行荷重試驗，緩降機至少應載重 X kg 以上；救助袋應載重 Y kg 以…",{"webId":115,"number":116,"stem":117,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-023",23,"火焰探測器偵測火災為偵測火場的何種參數？",{"webId":119,"number":120,"stem":121,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-024",24,"某工廠室內製程區其燃氣設備使用之燃氣以丙烷（C3H8）為主成分，現場欲設置可燃氣漏氣警報設備時，檢知器應如何安裝？",{"webId":123,"number":12,"stem":124,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-025","依 119 火災通報裝置認可基準規定，當常用電源停電，持續 X 分鐘待機狀態後，需保有 Y 分鐘以上可進行火災通報之…",{"webId":126,"number":127,"stem":128,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-026",26,"因疫情消毒需求，某醫院院區之一間獨立庫房存放 75%酒精之備用囤放量遽增，下列何因素使該庫房須設置火警自動警報設備移…",{"webId":130,"number":131,"stem":132,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-027",27,"以絕緣電阻計量測 220 V 電源之火警受信總機回路絕緣電阻，下列何者正確？",{"webId":134,"number":135,"stem":136,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-028",28,"非局限型探測器為有效偵知火災，下列何者為設置標準規定裝設於小空間內至少應有的長度或元件數量？",{"webId":138,"number":139,"stem":140,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-029",29,"緩降機為顧及使用之安全，裝置時應考慮之位置下列何者為佳？",{"webId":142,"number":143,"stem":144,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-030",30,"依各類場所消防安全設備設置標準規定，有關緊急廣播設備敘述下列何者錯誤？",{"webId":146,"number":147,"stem":148,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-031",31,"設置 119 火災通報裝置的主要功能為何？",{"webId":150,"number":151,"stem":152,"answer":26,"indexable":13},"fire-111-1-alarm-evacuation-032",32,"某場所進行緊急廣播設備綜合檢查，使用噪音計（A 特性）量測揚聲器之音壓位準，在距 L 級揚聲器 1 公尺處，音壓位準…",{"webId":154,"number":155,"stem":156,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-033",33,"依消防安全設備測試報告書測試方法及判定要領，有關瓦斯漏氣火警自動警報設備檢知器之動作試驗，以加瓦斯試驗器將試驗瓦斯加…",{"webId":158,"number":159,"stem":160,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-034",34,"二氧化碳滅火系統全區放射的空間，以往造成人員死傷之動作噴發，與防護空間下列因素何者無關？",{"webId":162,"number":163,"stem":164,"answer":36,"indexable":13},"fire-111-1-alarm-evacuation-035",35,"依緊急廣播設備用揚聲器認可基準規定，下列何者為指向特性 N 之揚聲器服務範圍圖（音域圖）？",{"webId":166,"number":167,"stem":168,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-036",36,"探測器安裝與天花板冷氣出風口應保持適當之距離，與火警探測器認可基準之下列何者有關？",{"webId":170,"number":171,"stem":172,"answer":26,"indexable":13},"fire-111-1-alarm-evacuation-037",37,"醫院之排煙設備進行綜合檢查時，緊急電源之檢查應如何落實？",{"webId":174,"number":175,"stem":176,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-038",38,"依消防安全設備及必要檢修項目檢修基準，針對緩降機之下降空間進行外觀檢查時，確認有無妨礙下降之物品，及有無確保下降必要…",{"webId":178,"number":179,"stem":180,"answer":31,"indexable":13},"fire-111-1-alarm-evacuation-039",39,"民國 84 年取得使用執照之大樓，測試其火警地區音響裝置之音壓何者正確？",{"webId":182,"number":183,"stem":184,"answer":45,"indexable":13},"fire-111-1-alarm-evacuation-040",40,"光電式分離型探測器進行外觀試驗，以目視確認探測器光軸應平行牆壁距離 X 公分以上，且探測器之光軸高度應在天花板等高度…",50,1785123168629]