[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-alarm-evacuation-114-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"警報與避難系統消防安全設備概要","alarm-evacuation",114,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"某百貨公司發生爆炸事件，依各類場所消防安全設備設置標準第 21 條規定，有關使用瓦斯應設置瓦斯漏氣火警自動警報設備之場所為何？依消防安全設備及必要檢修項目檢修基準規定，有關性能檢查 (三)檢知器，檢知器選取檢查數量表之規定為何？對於瓦斯漏氣火警自動警報設備進行綜合檢查時，有關綜合動作部分，其檢查方法、判定方法及注意事項為何？（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"某醫院操作緩降機發生受傷事件，依各類場所消防安全設備設置標準第 167 條規定，請說明緩降機使用時，有關繩子設置規定為何？依消防安全設備及必要檢修項目檢修基準規定，對於緩降機進行綜合檢查時，有關下降部分，其檢查方法、判定方法及注意事項為何？（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"警報與避難系統","警報與避難 · Alarm & Egress","探測器、受信總機、緊急廣播,加上標示設備、緊急照明與避難器具——條號最零碎,也最吃「表格記憶」。","警報系統抓火警分區劃定原則、各型探測器(差動式局限型\u002F分布型、定溫式、偵煙式)的裝置場所與高度限制、受信總機與緊急電源;避難系統抓出口\u002F避難方向指示燈的設置與有效範圍、緊急照明照度、緩降機與避難器具的設置數量與開口面規定。條文以表格呈現者多,建議整理成對照表背。",[23,27,31,36,42,46,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":13},"fire-114-1-alarm-evacuation-001","某防火構造建築物位於 2 樓的商業賣場，若其員工共 30 人，賣場部分的樓地板面積為 1,000 平方公尺，同 1 …","A",{"webId":28,"number":15,"stem":29,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-002","某防火構造建築物設有密閉冷凍室，其冷凍室之面積為 240 平方公尺，天花板高度為 3.6 公尺，當設置定溫式局限型探…","B",{"webId":32,"number":33,"stem":34,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-003",3,"下列那些環境因素較不容易造成局限型偵煙探測器之誤動作？","C",{"webId":37,"number":38,"stem":39,"answer":40,"indexable":41},"fire-114-1-alarm-evacuation-004",4,"某電影院放映場所火警自動警報設備所使用之蓄積型偵煙探測器有 10 秒之蓄積時間，其所使用之中繼器有 10 秒之蓄積時…","D",true,{"webId":43,"number":44,"stem":45,"answer":40,"indexable":13},"fire-114-1-alarm-evacuation-005",5,"有一安養機構設在 1 棟防火構造建築物內第 3 樓層內，依各類場所消防安全設備設置標準規定其避難器具之選擇設置，下列…",{"webId":47,"number":48,"stem":49,"answer":26,"indexable":13},"fire-114-1-alarm-evacuation-006",6,"依各類場所消防安全設備設置標準，緊急廣播設備之揚聲器裝設於樓梯間時，垂直距離至少每 X 公尺設一個揚聲器，且該距揚聲…",{"webId":51,"number":52,"stem":53,"answer":40,"indexable":13},"fire-114-1-alarm-evacuation-007",7,"有一安養中心為防火構造建築物，其樓層數為地下 2 層地上 6 層，各樓層高度 3 公尺、樓地板面積 1,200 平方…",{"webId":55,"number":56,"stem":57,"answer":26,"indexable":13},"fire-114-1-alarm-evacuation-008",8,"依各類場所消防安全設備設置標準，下列火警探測器之裝置位置規定何者錯誤？",{"webId":59,"number":60,"stem":61,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-009",9,"依各類場所消防安全設備設置標準規定，火焰型探測器可設於下列那一場所？",{"webId":63,"number":64,"stem":65,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-010",10,"檢修申報複查時，有關探測器之動作時間，下列何者錯誤？",{"webId":67,"number":68,"stem":69,"answer":26,"indexable":13},"fire-114-1-alarm-evacuation-011",11,"依各類場所消防安全設備設置標準，有關於出口標示燈及避難方向指示燈之設置規定何者錯誤？",{"webId":71,"number":72,"stem":73,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-012",12,"某捷運站的挑高通道設有蓄積時間 10 秒的光電式分離型式蓄積型探測器，在消防安全設備及必要檢修項目檢修基準中進行性能…",{"webId":75,"number":76,"stem":77,"answer":40,"indexable":13},"fire-114-1-alarm-evacuation-013",13,"依各類場所消防安全設備設置標準，下列何場所不用設置無線電通信輔助設備？",{"webId":79,"number":80,"stem":81,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-014",14,"某地下街餐廳廚房設有瓦斯漏氣火警自動警報設備，其瓦斯燃燒器具使用管線配管提供的天然氣為燃料時，下列敘述何者錯誤？",{"webId":83,"number":84,"stem":85,"answer":26,"indexable":13},"fire-114-1-alarm-evacuation-015",15,"依各類場所消防安全設備設置標準，下列場所何者應設置防災監控系統綜合操作裝置？",{"webId":87,"number":88,"stem":89,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-016",16,"依各類場所消防安全設備設置標準，出口標示燈及避難方向指示燈之緊急電源之設置規定，下列何者正確？",{"webId":91,"number":92,"stem":93,"answer":40,"indexable":13},"fire-114-1-alarm-evacuation-017",17,"有關火警自動警報設備的差動式分布型探測器，依各類場所消防安全設備設置標準規定何者正確？",{"webId":95,"number":96,"stem":97,"answer":26,"indexable":13},"fire-114-1-alarm-evacuation-018",18,"依各類場所消防安全設備設置標準，對於火警自動警報設備之設置場所敘述，下列何者錯誤？",{"webId":99,"number":100,"stem":101,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-019",19,"下列場所何者依各類場所消防安全設備設置標準，不用設置一一九火災通報裝置？",{"webId":103,"number":104,"stem":105,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-020",20,"依各類場所消防安全設備設置標準，緊急廣播設備揚聲器在下列廣播區域的規定，何者錯誤？",{"webId":107,"number":108,"stem":109,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-021",21,"依照火焰探測器之原理，下列何者與火焰探測器之作動有關？",{"webId":111,"number":112,"stem":113,"answer":40,"indexable":13},"fire-114-1-alarm-evacuation-022",22,"未設置絕緣異常警報裝置的火警受信總機，檢修維護時以直流 500 V 之絕緣電阻計測量絕緣測試，下列何者錯誤？",{"webId":115,"number":116,"stem":117,"answer":40,"indexable":13},"fire-114-1-alarm-evacuation-023",23,"乾燥室是顯著高溫之場所，下列何種探測器適用選擇設置？",{"webId":119,"number":120,"stem":121,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-024",24,"依消防安全設備及必要檢修項目檢修基準規定，應備有識別火警分區之圖面資料，下列何者正確？",{"webId":123,"number":12,"stem":124,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-025","有關防煙區劃及防煙壁之設置，下列何者錯誤？",{"webId":126,"number":127,"stem":128,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-026",26,"檢測探測器時，其動作時間下列何者錯誤？",{"webId":130,"number":131,"stem":132,"answer":40,"indexable":13},"fire-114-1-alarm-evacuation-027",27,"拆解局限型偵煙探測器外殼，所見內部構造下列敘述何者正確？",{"webId":134,"number":135,"stem":136,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-028",28,"下列建築物何者得免設火警自動警報設備？",{"webId":138,"number":139,"stem":140,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-029",29,"1 層樓之樓地板面積 300 平方公尺的「無開口樓層」建築物，供中醫診所用途之消防安全設備檢討，何者錯誤？",{"webId":142,"number":143,"stem":144,"answer":26,"indexable":13},"fire-114-1-alarm-evacuation-030",30,"有關與建築物外牆開口面積相關之規定何者錯誤？",{"webId":146,"number":147,"stem":148,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-031",31,"有關一一九火災通報裝置設置規定，何者錯誤？",{"webId":150,"number":151,"stem":152,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-032",32,"民國 113 年取得使用執照之 5 樓以下建築物，於 114 年檢修申報複查時，發現外牆增加部分固定式廣告屏障，影響…",{"webId":154,"number":155,"stem":156,"answer":26,"indexable":13},"fire-114-1-alarm-evacuation-033",33,"下列應設置排煙設備之場所規模何者錯誤？",{"webId":158,"number":159,"stem":160,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-034",34,"依各類場所消防安全設備設置標準規定，有關緊急廣播系統揚聲器，距其 1 公尺處所測得之音壓，下列敘述何者正確？",{"webId":162,"number":163,"stem":164,"answer":40,"indexable":13},"fire-114-1-alarm-evacuation-035",35,"有關消防排煙機採用 3 相 220 V 電動機及周邊連動設備之相關規定，下列何者錯誤？",{"webId":166,"number":167,"stem":168,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-036",36,"購物中心之挑高空間高度 18 公尺，設有 skylight 採光天窗，火警探測器之設置何者錯誤？",{"webId":170,"number":171,"stem":172,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-037",37,"兩棟旅館欲以過廊連接，並分別各自檢討消防設備，下列相關規定何者正確？",{"webId":174,"number":175,"stem":176,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-038",38,"護理之家配合主管機關政策，加強消防安全設備之改善，涉及部分消防設備變動，依原有合法建築物公共安全改善辦法改善，下列有…",{"webId":178,"number":179,"stem":180,"answer":35,"indexable":13},"fire-114-1-alarm-evacuation-039",39,"地下捷運車站消防搶救不易，面積達 1 千平方公尺時，下列之消防設備何者得免設？",{"webId":182,"number":183,"stem":184,"answer":30,"indexable":13},"fire-114-1-alarm-evacuation-040",40,"有關防災監控系統綜合操作裝置之消防搶救支援性能的 LCD 等構成系統部分，應能簡明表示所有樓層平面圖及與該樓層有關之…",50,1785123168601]