[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-water-chemical-107-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"水與化學系統消防安全設備概要","water-chemical",107,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"㈠請說明加壓式乾粉滅火系統中，遲延裝置、定壓動作裝置、壓力調整裝置、清洗裝置以及排出裝置等各裝置之作用。（15 分） ㈡另請說明定壓動作裝置之類型及作動原理。（10 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"採用幫浦加壓之密閉式撒水系統，依「各類場所消防安全設備檢修及申報作業基準」進行綜合檢查時，請說明其檢查方法、判定方法及注意事項。（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"水與化學系統","水與化學系統 · Water & Chemical","室內外消防栓、自動撒水、水霧泡沫,加上二氧化碳、乾粉與惰性氣體滅火設備——法定數值與檢修判定的重災區。","水系統抓消防栓放水壓力與放水量(室內 1.7、室外 2.5 kgf\u002Fcm² 等門檻)、撒水頭配置與撒水頭迴水板高度、水源容量計算;化學系統抓二氧化碳\u002F乾粉\u002F惰性氣體的設計濃度、藥劑量計算與放射時間,並注意《檢修基準》的性能檢查與判定值。計算題全 corpus 61 題,次於火災學。",[23,28,32,36,41,45,49,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-107-1-water-chemical-001","撒水頭之設置位置規定中，撒水頭迴水板下方 A 公分內及水平方向 B 公分內，應保持淨空間，不得有障礙物，其中 A、B…","D",true,{"webId":29,"number":15,"stem":30,"answer":31,"indexable":27},"fire-107-1-water-chemical-002","有關連結送水管之送水口設置規定，下列何者錯誤？","A",{"webId":33,"number":34,"stem":35,"answer":26,"indexable":27},"fire-107-1-water-chemical-003",3,"水霧滅火設備之水源容量規定，下列何者正確？",{"webId":37,"number":38,"stem":39,"answer":40,"indexable":27},"fire-107-1-water-chemical-004",4,"移動式泡沫滅火設備之水源容量，依規定為 2 具泡沫瞄子同時放水多少分鐘之水量以上？","B",{"webId":42,"number":43,"stem":44,"answer":31,"indexable":27},"fire-107-1-water-chemical-005",5,"泡沫滅火設備使用泡沫噴頭時，每一放射區域之樓地板面積規定應為何？",{"webId":46,"number":47,"stem":48,"answer":40,"indexable":27},"fire-107-1-water-chemical-006",6,"泡沫滅火系統中，採高發泡全區放射時，冠泡體積係指防護區域自樓地板面至高出防護對象最高點多少公尺所圍體積？",{"webId":50,"number":51,"stem":52,"answer":53,"indexable":27},"fire-107-1-water-chemical-007",7,"自動撒水設備應裝置適當之流水檢知裝置，有關流水檢知裝置之設置規定，下列何者正確？","C",{"webId":55,"number":56,"stem":57,"answer":53,"indexable":27},"fire-107-1-water-chemical-008",8,"水滅火系統中，以立管連接屋頂水箱使配管平時充滿水，屋頂水箱之容量要求，下列何者錯誤？",{"webId":59,"number":60,"stem":61,"answer":40,"indexable":27},"fire-107-1-water-chemical-009",9,"某一學校教學大樓每一樓層皆設有第一種室內消防栓 3 具，則其水源容量應為多少立方公尺？",{"webId":63,"number":64,"stem":65,"answer":53,"indexable":27},"fire-107-1-water-chemical-010",10,"第一種室內消防栓採用消防幫浦做為加壓送水裝置時，假設水帶摩擦損失水頭為 3 m，配管磨擦損失水頭為 7 m，落差為 …",{"webId":67,"number":68,"stem":69,"answer":26,"indexable":27},"fire-107-1-water-chemical-011",11,"加壓式乾粉滅火設備，於啟動裝置動作後，為使儲存容器壓力達設定壓力始開啟放出閥，應設置何種裝置？",{"webId":71,"number":72,"stem":73,"answer":26,"indexable":27},"fire-107-1-water-chemical-012",12,"設置乾粉滅火設備時，全區及局部放射之緊急電源應為自用發電設備或蓄電池設備，其容量應能使設備有效動作多久以上？",{"webId":75,"number":76,"stem":77,"answer":26,"indexable":27},"fire-107-1-water-chemical-013",13,"有關二氧化碳滅火設備配管之設置規定，下列何者正確？",{"webId":79,"number":80,"stem":81,"answer":40,"indexable":27},"fire-107-1-water-chemical-014",14,"二氧化碳滅火系統採全區放射方式高壓式系統，共設有 24 瓶儲存容器，進行綜合檢查時，放射試驗所需之藥劑量，應為下列何…",{"webId":83,"number":84,"stem":85,"answer":40,"indexable":27},"fire-107-1-water-chemical-015",15,"二氧化碳滅火系統進行性能檢查時，音響警報之判定方法為距警報裝置 X 公尺處之音量應在 Y 分貝以上，其中 X、Y 應…",{"webId":87,"number":88,"stem":89,"answer":53,"indexable":27},"fire-107-1-water-chemical-016",16,"有關乾粉滅火系統之放射時間，下列敘述何者正確？",{"webId":91,"number":92,"stem":93,"answer":31,"indexable":27},"fire-107-1-water-chemical-017",17,"一電氣設備室長寬高分別為 12 m、8 m 及 4 m，若採二氧化碳全區放射滅火設備防護，藥劑放射後採機械排放，則其…",{"webId":95,"number":96,"stem":97,"answer":53,"indexable":27},"fire-107-1-water-chemical-018",18,"有關大型滅火器之敘述，下列何者正確？",{"webId":99,"number":100,"stem":101,"answer":40,"indexable":27},"fire-107-1-water-chemical-019",19,"可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽之滅火器，每具滅火器對普通火災應具有 X 個以上之滅火效能…",{"webId":103,"number":104,"stem":105,"answer":40,"indexable":27},"fire-107-1-water-chemical-020",20,"室內消防栓之水源採重力水箱設置，下列何種裝置不屬於該構造應有之裝置？",{"webId":107,"number":108,"stem":109,"answer":31,"indexable":27},"fire-107-1-water-chemical-021",21,"有關乾粉滅火設備配管設置規定，下列敘述何者正確？",{"webId":111,"number":112,"stem":113,"answer":26,"indexable":27},"fire-107-1-water-chemical-022",22,"可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽設置滅火器，其設置規定，下列敘述何者正確？",{"webId":115,"number":116,"stem":117,"answer":40,"indexable":27},"fire-107-1-water-chemical-023",23,"有關室內消防栓綜合檢查放水量及放水壓力之敘述，下列何者正確？",{"webId":119,"number":120,"stem":121,"answer":53,"indexable":27},"fire-107-1-water-chemical-024",24,"竣工查驗時，於屋頂使用口徑 16 mm 瞄子實施第一種室內消防栓綜合檢查，測得放水壓力為 4 kgf\u002Fcm2，所計算…",{"webId":123,"number":12,"stem":124,"answer":31,"indexable":27},"fire-107-1-water-chemical-025","泡沫滅火設備進行綜合檢查時，有關泡沫滅火藥劑 25%還原時間標準值敘述，下列何者正確？",{"webId":126,"number":127,"stem":128,"answer":26,"indexable":27},"fire-107-1-water-chemical-026",26,"室內消防栓設備之消防立管管系竣工時，應做加壓試驗，試驗壓力不得小於加壓送水裝置全閉揚程 A 倍以上之水壓。試驗壓力以…",{"webId":130,"number":131,"stem":132,"answer":53,"indexable":27},"fire-107-1-water-chemical-027",27,"有關二氧化碳滅火設備放射時間之敘述，下列何者正確？",{"webId":134,"number":135,"stem":136,"answer":31,"indexable":27},"fire-107-1-water-chemical-028",28,"有關滅火器性能檢查頻率之規定，下列敘述何者正確？",{"webId":138,"number":139,"stem":140,"answer":40,"indexable":27},"fire-107-1-water-chemical-029",29,"全區放射二氧化碳滅火設備進行綜合檢查時，如為高壓式儲存系統，在放射試驗時需放射多少藥劑量？",{"webId":142,"number":143,"stem":144,"answer":26,"indexable":27},"fire-107-1-water-chemical-030",30,"實施二氧化碳滅火設備檢修，於進行性能檢查時，皮管連接部應無鬆動，皮管損傷、老化等情形，且皮管長度應在幾公尺以上？",{"webId":146,"number":147,"stem":148,"answer":40,"indexable":27},"fire-107-1-water-chemical-031",31,"惰性氣體滅火設備進行性能檢查時，對於滅火藥劑量判定方法，藥劑量測定結果與重量表、圖面明細表或原廠技術手冊規範等資料核…",{"webId":150,"number":151,"stem":152,"answer":53,"indexable":27},"fire-107-1-water-chemical-032",32,"泡沫滅火設備之場所，於進行性能檢查時，製造年份超過幾年或無法辨識製造年份之水帶，應進行水壓試驗？",{"webId":154,"number":155,"stem":156,"answer":53,"indexable":27},"fire-107-1-water-chemical-033",33,"自動撒水設備竣工時進行加壓試驗，下列何者錯誤？",{"webId":158,"number":159,"stem":160,"answer":40,"indexable":27},"fire-107-1-water-chemical-034",34,"依 NFPA 2001 之規定，潔淨式氣體滅火系統於一般場所之藥劑放射時間（達設計濃度 95%之時間），下列敘述何者…",{"webId":162,"number":163,"stem":164,"answer":53,"indexable":27},"fire-107-1-water-chemical-035",35,"採用移動式放射方式之乾粉滅火設備，藥劑種類為第一種乾粉時，每一具噴射瞄子所需藥劑放射量為：",{"webId":166,"number":167,"stem":168,"answer":40,"indexable":27},"fire-107-1-water-chemical-036",36,"有關自動撒水設備末端查驗閥之敘述，下列何者正確？",{"webId":170,"number":171,"stem":172,"answer":26,"indexable":27},"fire-107-1-water-chemical-037",37,"有關撒水頭設置之敘述，下列何者正確？",{"webId":174,"number":175,"stem":176,"answer":53,"indexable":27},"fire-107-1-water-chemical-038",38,"依各類場所消防安全設備設置標準之規定，下列何種場所不需設置室外消防栓設備？",{"webId":178,"number":179,"stem":180,"answer":31,"indexable":27},"fire-107-1-water-chemical-039",39,"為執行檢修申報，針對水霧滅火系統綜合檢查，對於判定方法之敘述，下列何者正確？",{"webId":182,"number":183,"stem":184,"answer":31,"indexable":27},"fire-107-1-water-chemical-040",40,"進行幫浦性能試驗時，幫浦之出水量在額定出水量之 1.5 倍時，其全揚程應為額定出水量在性能曲線上全揚程百分之多少以上…",50,1785123164425]