[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-water-chemical-114-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"水與化學系統消防安全設備概要","water-chemical",114,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"請說明乾粉滅火藥劑之滅火原理？（10 分）乾粉滅火藥劑種類及主要成分各為何？（15 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"請說明室內消防栓箱等之外觀檢查、性能檢查之檢查方法及判定方法為何？（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"水與化學系統","水與化學系統 · Water & Chemical","室內外消防栓、自動撒水、水霧泡沫,加上二氧化碳、乾粉與惰性氣體滅火設備——法定數值與檢修判定的重災區。","水系統抓消防栓放水壓力與放水量(室內 1.7、室外 2.5 kgf\u002Fcm² 等門檻)、撒水頭配置與撒水頭迴水板高度、水源容量計算;化學系統抓二氧化碳\u002F乾粉\u002F惰性氣體的設計濃度、藥劑量計算與放射時間,並注意《檢修基準》的性能檢查與判定值。計算題全 corpus 61 題,次於火災學。",[23,27,30,35,40,45,49,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":13},"fire-114-1-water-chemical-001","因應老人福利機構人力短缺及照護人員多為女性之境況，以設置單人易於操作之第二種室內消防栓較佳。有關第二種室內消防栓之設…","B",{"webId":28,"number":15,"stem":29,"answer":26,"indexable":13},"fire-114-1-water-chemical-002","依各類場所消防安全設備設置標準規定，惰性氣體滅火設備於常時有人之場所，其藥劑最高設計濃度以多少為限？",{"webId":31,"number":32,"stem":33,"answer":34,"indexable":13},"fire-114-1-water-chemical-003",3,"依各類場所消防安全設備設置標準規定，惰性氣體滅火設備之藥劑種類及容量比，下列何者錯誤？","D",{"webId":36,"number":37,"stem":38,"answer":26,"indexable":39},"fire-114-1-water-chemical-004",4,"依各類場所消防安全設備設置標準規定，鹵化烴滅火設備，蓄壓式儲存容器儲存 HFC-227ea、 FK-5-1-12 之…",true,{"webId":41,"number":42,"stem":43,"answer":44,"indexable":13},"fire-114-1-water-chemical-005",5,"惰性氣體及鹵化烴滅火設備之防護區域竣工時，應做防護區域完整性測試，X 分鐘內之氣體洩漏量使滅火藥劑維持在設計濃度 Y…","A",{"webId":46,"number":47,"stem":48,"answer":44,"indexable":13},"fire-114-1-water-chemical-006",6,"依各類場所消防安全設備設置標準規定，鹵化烴滅火設備於常時有人之場所，其藥劑最高設計濃度，HFC-23：X %、HFC…",{"webId":50,"number":51,"stem":52,"answer":53,"indexable":13},"fire-114-1-water-chemical-007",7,"依各類場所消防安全設備設置標準規定，有關全區放射方式化學滅火設備之噴頭放射壓力規定，下列何者錯誤？","C",{"webId":55,"number":56,"stem":57,"answer":34,"indexable":13},"fire-114-1-water-chemical-008",8,"乾粉滅火設備配管設置，最低配管與最高配管間，落差在 X 公尺以下，且配管任一部分與彎曲部分之距離應為管徑 Y 倍以上…",{"webId":59,"number":60,"stem":61,"answer":34,"indexable":13},"fire-114-1-water-chemical-009",9,"平時供不特定人員使用之電腦室，樓地板面積在 200 平方公尺以上，得選擇下列何種滅火設備設置？①二氧化碳 ②惰性氣體…",{"webId":63,"number":64,"stem":65,"answer":53,"indexable":13},"fire-114-1-water-chemical-010",10,"針對滅火器實施外觀檢查，有關滅火器設置間距之判定方法，下列敘述何者錯誤？",{"webId":67,"number":68,"stem":69,"answer":26,"indexable":13},"fire-114-1-water-chemical-011",11,"依滅火器認可基準規定，某種滅火器滅火效能值標示 B-20，該滅火器實施滅火效能值之第二種滅火試驗方式，下列敘述何者錯…",{"webId":71,"number":72,"stem":73,"answer":53,"indexable":13},"fire-114-1-water-chemical-012",12,"某場所設置消防專用蓄水池採機械方式引水，且依規定設有 2 個採水口。若距離蓄水池最遠端之採水口配管摩擦損失水頭為 5…",{"webId":75,"number":76,"stem":77,"answer":53,"indexable":13},"fire-114-1-water-chemical-013",13,"連結送水管之出水口，應設於建築物第 X 層以上各層樓梯間或緊急昇降機間，且各層任一點至出水口之水平距離應在 Y 公尺…",{"webId":79,"number":80,"stem":81,"answer":44,"indexable":13},"fire-114-1-water-chemical-014",14,"因應電動車的普及，室內停車空間設計得採用自動撒水設備，下列敘述何者錯誤？",{"webId":83,"number":84,"stem":85,"answer":44,"indexable":13},"fire-114-1-water-chemical-015",15,"依各類場所消防安全設備設置標準規定，儲存硫磺之室內、外儲槽場所，屬顯著滅火困難場所，設置第三種滅火設備應選擇下列何種…",{"webId":87,"number":88,"stem":89,"answer":34,"indexable":13},"fire-114-1-water-chemical-016",16,"水霧滅火設備之放射區域有二區以上時，其主管管徑不得小於 X 毫米，其水源容量應保持在 Y 立方公尺以上。則 X+Y …",{"webId":91,"number":92,"stem":93,"answer":53,"indexable":13},"fire-114-1-water-chemical-017",17,"依水道連結型自動撒水設備設置基準規定，有關使用獨立水箱式類型之水道連結型自動撒水設備，下列敘述何者正確？",{"webId":95,"number":96,"stem":97,"answer":44,"indexable":13},"fire-114-1-water-chemical-018",18,"公共危險物品等場所達顯著滅火困難者，設置第一種滅火設備室內消防栓，今於裝置消防栓最多之最高樓層進行綜合檢查放水試驗，…",{"webId":99,"number":100,"stem":101,"answer":26,"indexable":13},"fire-114-1-water-chemical-019",19,"有關連結送水管之敘述，下列何者正確？",{"webId":103,"number":104,"stem":105,"answer":26,"indexable":13},"fire-114-1-water-chemical-020",20,"建築物高度超過多少公尺時，其連結送水管應採用濕式？",{"webId":107,"number":108,"stem":109,"answer":44,"indexable":13},"fire-114-1-water-chemical-021",21,"一般場所設置室外消防栓時，瞄子放水壓力超過每平方公分多少公斤時，應採減壓設施？",{"webId":111,"number":112,"stem":113,"answer":34,"indexable":13},"fire-114-1-water-chemical-022",22,"消防專用蓄水池採機械方式引水，若其落差 10 公尺，配管摩擦損失水頭 5 公尺，則其加壓送水裝置幫浦全揚程應為多少公…",{"webId":115,"number":116,"stem":117,"answer":44,"indexable":13},"fire-114-1-water-chemical-023",23,"設置室外消防栓之場所，應於其 X 公尺內附設水帶箱，於其 Y 公尺內保持空曠，則 X 與 Y 各為多少？",{"webId":119,"number":120,"stem":121,"answer":53,"indexable":13},"fire-114-1-water-chemical-024",24,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，消防幫浦出水量在額定出水量時，在其性能曲線上之全揚程必須達到額定揚程…",{"webId":123,"number":12,"stem":124,"answer":26,"indexable":13},"fire-114-1-water-chemical-025","飛機庫等場所設置泡水噴頭，其噴頭放射量應在每分鐘多少公升以上？",{"webId":126,"number":127,"stem":128,"answer":26,"indexable":13},"fire-114-1-water-chemical-026",26,"汽車修理廠、室內停車空間及昇降機械式停車場，設置自動撒水設備時，任一點至撒水頭之水平距離在多少公尺以下？",{"webId":130,"number":131,"stem":132,"answer":26,"indexable":13},"fire-114-1-water-chemical-027",27,"設置密閉式撒水頭場所平時最高周圍溫度約為攝氏 50 度，應選擇下列何種標示溫度之撒水頭？",{"webId":134,"number":135,"stem":136,"answer":26,"indexable":13},"fire-114-1-water-chemical-028",28,"密閉乾式撒水頭在撒水頭動作後，流水檢知裝置應在多少時間內，使撒水頭放水？",{"webId":138,"number":139,"stem":140,"answer":44,"indexable":13},"fire-114-1-water-chemical-029",29,"發電機室設置水霧滅火設備時，其出水壓力應在每平方公分多少公斤以上？",{"webId":142,"number":143,"stem":144,"answer":44,"indexable":13},"fire-114-1-water-chemical-030",30,"中央主管機關認定儲存大量可燃物之場所天花板高度超過 X 公尺，或其他場所天花板高度超過 Y 公尺者，應採用放水型撒水…",{"webId":146,"number":147,"stem":148,"answer":53,"indexable":13},"fire-114-1-water-chemical-031",31,"二氧化碳滅火設備採移動放射方式，每一具噴射瞄子所需滅火藥劑量在 X 公斤以上，瞄子之藥劑放射量在溫度攝氏 20 度時…",{"webId":150,"number":151,"stem":152,"answer":44,"indexable":13},"fire-114-1-water-chemical-032",32,"密閉式撒水設備進行綜合檢查時，末端查驗管之放水壓力合格判定標準為何？",{"webId":154,"number":155,"stem":156,"answer":26,"indexable":13},"fire-114-1-water-chemical-033",33,"鹵化烴滅火設備進行性能檢查時，氣壓式選擇閥開放裝置以試驗用二氧化碳容器自操作管連接部加壓，若試驗用容器內容積為 1 …",{"webId":158,"number":159,"stem":160,"answer":26,"indexable":13},"fire-114-1-water-chemical-034",34,"依各類場所消防安全設備設置標準規定，有關高架儲存倉庫設置自動撒水設備，下列敘述何者錯誤？",{"webId":162,"number":163,"stem":164,"answer":44,"indexable":13},"fire-114-1-water-chemical-035",35,"有關乾粉滅火設備加壓或蓄壓氣體之規定，下列敘述何者正確？",{"webId":166,"number":167,"stem":168,"answer":26,"indexable":13},"fire-114-1-water-chemical-036",36,"惰性氣體滅火設備之防護區域竣工時，應做防護區域完整性測試，10 分鐘內之氣體洩漏量使滅火藥劑維持在設計濃度多少以上者…",{"webId":170,"number":171,"stem":172,"answer":34,"indexable":13},"fire-114-1-water-chemical-037",37,"20 型 ABC 乾粉滅火器總重約 10 公斤，當進行外觀檢查之設置場所檢查時，滅火器本體上端與樓地板之距離合格判定…",{"webId":174,"number":175,"stem":176,"answer":26,"indexable":13},"fire-114-1-water-chemical-038",38,"有關二氧化碳及惰性氣體滅火設備手動啟動裝置設置之規定，下列敘述何者正確？",{"webId":178,"number":179,"stem":180,"answer":53,"indexable":13},"fire-114-1-water-chemical-039",39,"室內停車空間或汽車修理廠等場所設置泡沫滅火設備，樓地板面積每多少平方公尺應設置一個泡沫噴頭？",{"webId":182,"number":183,"stem":184,"answer":44,"indexable":13},"fire-114-1-water-chemical-040",40,"有關惰性氣體滅火設備噴頭設置之規定，下列敘述何者正確？",50,1785123164335]