[{"data":1,"prerenderedAt":181},["ShallowReactive",2],{"essay-water-chemical-115-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":180},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"水與化學系統消防安全設備概要","water-chemical",115,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"依據消防安全設備及必要檢修項目檢修基準第二章室內消防栓設備中，有關第一種消防栓之水帶及瞄子性能檢查的檢查方法與判定方法各為何？（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"依據消防安全設備及必要檢修項目檢修基準第十章海龍滅火設備，有關蓄壓式海龍滅火藥劑儲存容器等之性能檢查規定中，滅火藥劑量之檢查注意事項為何？（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"水與化學系統","水與化學系統 · Water & Chemical","室內外消防栓、自動撒水、水霧泡沫,加上二氧化碳、乾粉與惰性氣體滅火設備——法定數值與檢修判定的重災區。","水系統抓消防栓放水壓力與放水量(室內 1.7、室外 2.5 kgf\u002Fcm² 等門檻)、撒水頭配置與撒水頭迴水板高度、水源容量計算;化學系統抓二氧化碳\u002F乾粉\u002F惰性氣體的設計濃度、藥劑量計算與放射時間,並注意《檢修基準》的性能檢查與判定值。計算題全 corpus 61 題,次於火災學。",[23,27,30,35,40,44,48,52,56,61,65,69,73,77,81,85,89,93,97,101,105,109,113,117,121,124,128,132,136,140,144,148,152,156,160,164,168,172,176],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":13},"fire-115-1-water-chemical-001","有關消防幫浦性能試驗，下列敘述何者錯誤？","C",{"webId":28,"number":15,"stem":29,"answer":26,"indexable":13},"fire-115-1-water-chemical-002","某大樓設有室內消防栓設備，使用第一種室內消防栓，若該室內消防栓之瞄子壓力經檢測為 4 kg\u002Fcm2，試問在這種壓力下…",{"webId":31,"number":32,"stem":33,"answer":34,"indexable":13},"fire-115-1-water-chemical-003",3,"室內消防栓設備之消防立管管系竣工時，應做加壓試驗，試驗壓力不得小於加壓送水裝置全閉揚程 X 倍以上之水壓。試驗壓力以…","B",{"webId":36,"number":37,"stem":38,"answer":39,"indexable":13},"fire-115-1-water-chemical-004",4,"有關第二種室內消防栓設置之規定，下列敘述何者正確？","D",{"webId":41,"number":42,"stem":43,"answer":26,"indexable":13},"fire-115-1-water-chemical-005",5,"室內消防栓瞄子放水壓力超過 X Mpa 時，室外消防栓瞄子放水壓力超過 Y Mpa 時，應採取有效之減壓措施。X、Y…",{"webId":45,"number":46,"stem":47,"answer":26,"indexable":13},"fire-115-1-water-chemical-006",6,"應設置室外消防栓設備場所，同一建築基地內有二棟以上木造或其他易燃構造建築物時，建築物間外牆與中心線水平距離第一層在 …",{"webId":49,"number":50,"stem":51,"answer":39,"indexable":13},"fire-115-1-water-chemical-007",7,"儲存柴油（閃火點≧65℃）之作業場所，依各類場所消防安全設備設置標準規定，建築物及儲存場所之第一層及第二層樓地板面積…",{"webId":53,"number":54,"stem":55,"answer":34,"indexable":13},"fire-115-1-water-chemical-008",8,"某公共危險物品場所設置室外消防栓設備，在裝置全部消防栓數量 5 支時，其所需之水源容量至少應為多少立方公尺以上？",{"webId":57,"number":58,"stem":59,"answer":60,"indexable":13},"fire-115-1-water-chemical-009",9,"有關自動撒水設備之設置，下列敘述何者正確？","A",{"webId":62,"number":63,"stem":64,"answer":39,"indexable":13},"fire-115-1-water-chemical-010",10,"有關撒水頭之位置裝置規定，下列敘述何者正確？",{"webId":66,"number":67,"stem":68,"answer":26,"indexable":13},"fire-115-1-water-chemical-011",11,"裝置於舞臺之開放式自動撒水設備，下列敘述何者正確？",{"webId":70,"number":71,"stem":72,"answer":39,"indexable":13},"fire-115-1-water-chemical-012",12,"開放式自動撒水設備之自動及手動啟動裝置，下列敘述何者正確？",{"webId":74,"number":75,"stem":76,"answer":60,"indexable":13},"fire-115-1-water-chemical-013",13,"某一地下建築物，設置密閉式一般反應型撒水頭之自動撒水設備時，依各類場所消防安全設備設置標準規定，其水源容量不得小於 …",{"webId":78,"number":79,"stem":80,"answer":26,"indexable":13},"fire-115-1-water-chemical-014",14,"密閉乾式或預動式自動撒水設備之規定，下列敘述何者錯誤？",{"webId":82,"number":83,"stem":84,"answer":39,"indexable":13},"fire-115-1-water-chemical-015",15,"公共危險物品等場所設置自動撒水設備時，使用密閉式撒水頭其水源容量，應在設置 X 個撒水頭繼續放水 Y 分鐘之水量以上…",{"webId":86,"number":87,"stem":88,"answer":60,"indexable":13},"fire-115-1-water-chemical-016",16,"水霧滅火設備之水霧噴頭及配管與具有 9 KV 之高壓電器設備，最低應保持多少公厘之距離，以避免導電造成意外？",{"webId":90,"number":91,"stem":92,"answer":26,"indexable":13},"fire-115-1-water-chemical-017",17,"有關水霧滅火設備之規定，下列敘述何者正確？",{"webId":94,"number":95,"stem":96,"answer":39,"indexable":13},"fire-115-1-water-chemical-018",18,"水霧滅火設備之加壓送水裝置使用消防幫浦時，用於防護電氣設備者，每一個水霧噴頭壓力依規定均應達到多少 kgf\u002Fcm2 …",{"webId":98,"number":99,"stem":100,"answer":26,"indexable":13},"fire-115-1-water-chemical-019",19,"泡沫試料淨重為 200 g，還原數值如下，則 25%還原時間為何？時間（分） 0 0.5 1 1.5 2 2.5 3…",{"webId":102,"number":103,"stem":104,"answer":60,"indexable":13},"fire-115-1-water-chemical-020",20,"有關泡沫頭之規定，下列敘述何者錯誤？",{"webId":106,"number":107,"stem":108,"answer":26,"indexable":13},"fire-115-1-water-chemical-021",21,"高發泡放出口在全區放射防護區域內，樓地板面積每多少平方公尺應至少設置 1 個，且能有效放射至該區域，並附設泡沫放出停…",{"webId":110,"number":111,"stem":112,"answer":26,"indexable":13},"fire-115-1-water-chemical-022",22,"對於泡沫滅火設備構造與機能，下列敘述何者錯誤？",{"webId":114,"number":115,"stem":116,"answer":26,"indexable":13},"fire-115-1-water-chemical-023",23,"消防搶救上所需之連結送水管，應為專用，其立管管徑在一百公厘以上；但考量耐壓、經濟等因素，得與室內消防栓共用立管，其法…",{"webId":118,"number":119,"stem":120,"answer":60,"indexable":13},"fire-115-1-water-chemical-024",24,"任一消防專用蓄水池至建築物各部分之水平距離應在 A 公尺以下，且其有效水量在 B 立方公尺以上；並設於消防車能接近至…",{"webId":122,"number":12,"stem":123,"answer":60,"indexable":13},"fire-115-1-water-chemical-025","下列場所何者應設置滅火器？",{"webId":125,"number":126,"stem":127,"answer":26,"indexable":13},"fire-115-1-water-chemical-026",26,"乾粉滅火設備之緊急電源應為發電機設備或蓄電池設備，其容量應能使該設備有效動作多少分鐘以上？",{"webId":129,"number":130,"stem":131,"answer":26,"indexable":13},"fire-115-1-water-chemical-027",27,"下列何者不是可燃性高壓氣體製造場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽之防護設備？",{"webId":133,"number":134,"stem":135,"answer":39,"indexable":13},"fire-115-1-water-chemical-028",28,"鹵化烴滅火設備之防護區域竣工時，為維持放射藥劑濃度之有效性，需進行下列那一項測試程序？",{"webId":137,"number":138,"stem":139,"answer":60,"indexable":13},"fire-115-1-water-chemical-029",29,"鹵化烴滅火設備使用氣體啟動者，有關設置之規定，下列敘述何者正確？",{"webId":141,"number":142,"stem":143,"answer":26,"indexable":13},"fire-115-1-water-chemical-030",30,"某空間採用全區放射方式之第一種乾粉滅火設備（主成份為碳酸氫鈉）進行防護，則每立方公尺防護區域所需滅火藥劑量為多少 k…",{"webId":145,"number":146,"stem":147,"answer":34,"indexable":13},"fire-115-1-water-chemical-031",31,"在第三類公共危險物品之禁水性物質之作業場所設置消防安全設備時，下列何種滅火藥劑不宜選用？",{"webId":149,"number":150,"stem":151,"answer":26,"indexable":13},"fire-115-1-water-chemical-032",32,"有關二氧化碳滅火設備之放射時間，下列敘述何者正確？",{"webId":153,"number":154,"stem":155,"answer":39,"indexable":13},"fire-115-1-water-chemical-033",33,"對有 36 支高壓鋼瓶全區放射之二氧化碳滅火系統進行綜合檢查，放射試驗所需之藥劑量，應為多少支鋼瓶？",{"webId":157,"number":158,"stem":159,"answer":39,"indexable":13},"fire-115-1-water-chemical-034",34,"第五種滅火設備除滅火器外之其他設備，有關核算滅火效能值之規定，下列敘述何者正確？",{"webId":161,"number":162,"stem":163,"answer":60,"indexable":13},"fire-115-1-water-chemical-035",35,"在常時有人之場所，使用藥劑之最高設計濃度，下列敘述何者正確？",{"webId":165,"number":166,"stem":167,"answer":39,"indexable":13},"fire-115-1-water-chemical-037",37,"有關惰性氣體滅火設備之藥劑設計濃度之規定，下列敘述何者錯誤？",{"webId":169,"number":170,"stem":171,"answer":39,"indexable":13},"fire-115-1-water-chemical-038",38,"可燃性高壓氣體製造、儲存或處理場所，樓地板面積為三百三十平方公尺，設置之滅火器至少應多少具以上？",{"webId":173,"number":174,"stem":175,"answer":39,"indexable":13},"fire-115-1-water-chemical-039",39,"關於乾粉滅火設備加、蓄壓用氣體量，下列敘述何者正確？",{"webId":177,"number":178,"stem":179,"answer":34,"indexable":13},"fire-115-1-water-chemical-040",40,"下列何種滅火劑使用於金屬火災時，沒有「與金屬產生化學反應而衍生危害物質」的可能？",50,1785123164330]