[{"data":1,"prerenderedAt":562},["ShallowReactive",2],{"exam-106-1":3},{"ys":4,"year":5,"total":6,"essayTotal":7,"subjects":8},"106-1",106,160,8,[9,181,308,435],{"name":10,"slug":11,"kicker":12,"count":13,"explained":13,"list":14,"essay":178},"消防法規概要","fire-law","消防法規 · Fire Code",40,[15,21,26,30,34,39,43,47,50,54,59,63,67,71,75,79,83,87,91,95,99,103,107,111,115,119,123,127,131,135,139,143,147,151,155,159,163,167,171,175],{"webId":16,"number":17,"stem":18,"answer":19,"indexable":20},"fire-106-1-fire-law-001",1,"依規定應設置消防安全設備之場所，其管理權人應委託消防設備師或消防設備士定期檢修消防安全設備，其檢修方式中之綜合檢查係…","B",true,{"webId":22,"number":23,"stem":24,"answer":25,"indexable":20},"fire-106-1-fire-law-002",2,"依據消防法規定，下列何者應舉辦防火教育及宣導？","A",{"webId":27,"number":28,"stem":29,"answer":25,"indexable":20},"fire-106-1-fire-law-003",3,"下列有關公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之相關用語定義，何者正確？",{"webId":31,"number":32,"stem":33,"answer":19,"indexable":20},"fire-106-1-fire-law-004",4,"依各類場所消防安全設備設置標準規定，幼兒園按用途分類係屬於何種場所？",{"webId":35,"number":36,"stem":37,"answer":38,"indexable":20},"fire-106-1-fire-law-005",5,"依各類場所消防安全設備設置標準規定，下列何種場所應設置連結送水管？","C",{"webId":40,"number":41,"stem":42,"answer":38,"indexable":20},"fire-106-1-fire-law-006",6,"依據各類場所消防安全設備設置標準規定，集會堂使用之舞臺在設置自動撒水設備時，應選擇下列何者？",{"webId":44,"number":45,"stem":46,"answer":25,"indexable":20},"fire-106-1-fire-law-007",7,"依據各類場所消防安全設備設置標準規定，公共危險物品製造場所符合下列何者要件，則屬顯著滅火困難場所？",{"webId":48,"number":7,"stem":49,"answer":19,"indexable":20},"fire-106-1-fire-law-008","依據各類場所消防安全設備設置標準規定，對瓦斯漏氣檢知器設置，下列敘述何者正確？",{"webId":51,"number":52,"stem":53,"answer":19,"indexable":20},"fire-106-1-fire-law-009",9,"依據各類場所消防安全設備設置標準規定，公共危險物品等場所之滅火設備分類，下列敘述何者正確？",{"webId":55,"number":56,"stem":57,"answer":58,"indexable":20},"fire-106-1-fire-law-010",10,"依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，公共危險物品之範圍及分類下列何者正確？","D",{"webId":60,"number":61,"stem":62,"answer":25,"indexable":20},"fire-106-1-fire-law-011",11,"依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，儲存公共危險物品之數量在管制量 20 倍以下者，建築物之…",{"webId":64,"number":65,"stem":66,"answer":19,"indexable":20},"fire-106-1-fire-law-012",12,"依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，下列何種公共危險物品，不得儲放室外儲存場所？",{"webId":68,"number":69,"stem":70,"answer":19,"indexable":20},"fire-106-1-fire-law-013",13,"某一地下儲槽場所設置柴油儲槽，該儲槽上部未設有固定式滅火設備，而儲槽內容積為 3,000 公升，依據公共危險物品及可…",{"webId":72,"number":73,"stem":74,"answer":25,"indexable":20},"fire-106-1-fire-law-014",14,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，有關公共危險物品之儲存及處理，下列何者應避免與水接觸？",{"webId":76,"number":77,"stem":78,"answer":25,"indexable":20},"fire-106-1-fire-law-015",15,"依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，液化石油氣製造場所，其外牆或相當於該外牆之設施外側，與場…",{"webId":80,"number":81,"stem":82,"answer":19,"indexable":20},"fire-106-1-fire-law-016",16,"依據建築技術規則建築設計施工編規定，下列何者屬耐火板？",{"webId":84,"number":85,"stem":86,"answer":25,"indexable":20},"fire-106-1-fire-law-017",17,"依據消防法規定，為因應災害搶救時消防之需要，有關下列消防栓設置、費用、保養及維護，何者正確？",{"webId":88,"number":89,"stem":90,"answer":19,"indexable":20},"fire-106-1-fire-law-018",18,"依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，可燃性高壓氣體儲存場所設有防爆牆或同等以上防護性能者，倘…",{"webId":92,"number":93,"stem":94,"answer":58,"indexable":20},"fire-106-1-fire-law-019",19,"依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，壓力儲槽應設置安全裝置；非壓力儲槽應設置通氣管。上述壓力…",{"webId":96,"number":97,"stem":98,"answer":38,"indexable":20},"fire-106-1-fire-law-020",20,"依據各類場所消防安全設備設置標準規定，設置於可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽之滅火器，其滅…",{"webId":100,"number":101,"stem":102,"answer":19,"indexable":20},"fire-106-1-fire-law-021",21,"下列有關消防法施行細則第 14 條防火管理人規定之敘述，何者錯誤？",{"webId":104,"number":105,"stem":106,"answer":58,"indexable":20},"fire-106-1-fire-law-022",22,"下列有關消防法相關規定之敘述，何者錯誤？",{"webId":108,"number":109,"stem":110,"answer":38,"indexable":20},"fire-106-1-fire-law-023",23,"下列有關消防設備師及消防設備士管理辦法規定之敘述，何者錯誤？",{"webId":112,"number":113,"stem":114,"answer":38,"indexable":20},"fire-106-1-fire-law-024",24,"下列有關消防安全設備檢修專業機構管理辦法規定之敘述，何者錯誤？",{"webId":116,"number":117,"stem":118,"answer":19,"indexable":20},"fire-106-1-fire-law-025",25,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，下列有關六類物品製造場所之敘述，何者正確？",{"webId":120,"number":121,"stem":122,"answer":25,"indexable":20},"fire-106-1-fire-law-026",26,"下列有關防火水幕設備之水源容量規定之敘述，何者錯誤？",{"webId":124,"number":125,"stem":126,"answer":38,"indexable":20},"fire-106-1-fire-law-027",27,"下列有關防火牆及防火水幕設置基準規定之敘述，何者錯誤？",{"webId":128,"number":129,"stem":130,"answer":58,"indexable":20},"fire-106-1-fire-law-028",28,"依可燃性高壓氣體儲存場所防護牆設置基準規定，鋼筋混凝土製防護牆，其厚度應在多少 mm 以上？",{"webId":132,"number":133,"stem":134,"answer":19,"indexable":20},"fire-106-1-fire-law-029",29,"下列有關簡易自動滅火設備規定之敘述，何者錯誤？",{"webId":136,"number":137,"stem":138,"answer":38,"indexable":20},"fire-106-1-fire-law-030",30,"下列有關百貨商場收容人員之計算規定之敘述，何者錯誤？",{"webId":140,"number":141,"stem":142,"answer":25,"indexable":20},"fire-106-1-fire-law-031",31,"下列有關消防法施行細則第 15 條自衛消防編組規定之敘述，何者正確？",{"webId":144,"number":145,"stem":146,"answer":58,"indexable":20},"fire-106-1-fire-law-032",32,"水霧滅火設備水源，應連結加壓送水裝置。其用於防護電氣設備者，出水壓力達每平方公分多少公斤以上？",{"webId":148,"number":149,"stem":150,"answer":58,"indexable":20},"fire-106-1-fire-law-033",33,"建築物在五樓以上，且總樓地板面積在 3,000 平方公尺以上者，其火警自動警報設備鳴動方式之規定敘述，何者錯誤？",{"webId":152,"number":153,"stem":154,"answer":19,"indexable":20},"fire-106-1-fire-law-034",34,"各類場所之管理權人應委託檢修專業機構或消防法第 7 條規定之人員辦理檢修，並於檢修完成後幾日內，向當地消防機關申報？",{"webId":156,"number":157,"stem":158,"answer":25,"indexable":20},"fire-106-1-fire-law-035",35,"下列有關建築物消防安全設備竣工查驗程序規定之敘述，何者錯誤？",{"webId":160,"number":161,"stem":162,"answer":38,"indexable":20},"fire-106-1-fire-law-036",36,"下列有關各類場所消防安全設備檢修及申報作業基準行政函釋之敘述，何者錯誤？",{"webId":164,"number":165,"stem":166,"answer":19,"indexable":20},"fire-106-1-fire-law-037",37,"下列有關消防幫浦之性能規定之敘述，何者正確？",{"webId":168,"number":169,"stem":170,"answer":25,"indexable":20},"fire-106-1-fire-law-038",38,"下列有關建築技術規則建築設計施工編建築技術用語規定之敘述，何者錯誤？",{"webId":172,"number":173,"stem":174,"answer":19,"indexable":20},"fire-106-1-fire-law-039",39,"依據建築技術規則建築設計施工編規定，下列用語定義何者正確？",{"webId":176,"number":13,"stem":177,"answer":19,"indexable":20},"fire-106-1-fire-law-040","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，下列有關「六類物品製造場所，其外牆或相當於該外牆之設施外側…",{"count":23,"points":179,"split":180},50,[137,97],{"name":182,"slug":183,"kicker":184,"count":13,"explained":13,"list":185,"essay":306},"火災學概要","fire-science","火災學 · Fire Science",[186,189,192,195,198,201,204,207,210,213,216,219,222,225,228,231,234,237,240,243,246,249,252,255,258,261,264,267,270,273,276,279,282,285,288,291,294,297,300,303],{"webId":187,"number":17,"stem":188,"answer":58,"indexable":20},"fire-106-1-fire-science-001","某物質每克的燃燒熱為 1 仟焦耳，若 100 克該物質於 10 秒內平均燃燒完，則該物質之熱釋放率為：",{"webId":190,"number":23,"stem":191,"answer":25,"indexable":20},"fire-106-1-fire-science-002","造成工業火災的最高比率因素為何？",{"webId":193,"number":28,"stem":194,"answer":19,"indexable":20},"fire-106-1-fire-science-003","紅外線顯像儀器可量測下列何種量值？",{"webId":196,"number":32,"stem":197,"answer":38,"indexable":20},"fire-106-1-fire-science-004","關於火災紀錄的敘述，下列何者錯誤？",{"webId":199,"number":36,"stem":200,"answer":19,"indexable":20},"fire-106-1-fire-science-005","下列形成火災原因中，何者屬於硬體設備之因素？",{"webId":202,"number":41,"stem":203,"answer":58,"indexable":20},"fire-106-1-fire-science-006","通常可燃性氣體或液體之分子每莫耳燃燒熱大於多少 kcal\u002Fmole？",{"webId":205,"number":45,"stem":206,"answer":38,"indexable":20},"fire-106-1-fire-science-007","請指出下列何種氣體的比重小於 1？",{"webId":208,"number":7,"stem":209,"answer":58,"indexable":20},"fire-106-1-fire-science-008","硫磺固體之燃燒屬於下列何種燃燒型態？",{"webId":211,"number":52,"stem":212,"answer":38,"indexable":20},"fire-106-1-fire-science-009","燃燒之型態中，石油類之燃燒係屬下列何種型態燃燒？",{"webId":214,"number":56,"stem":215,"answer":38,"indexable":20},"fire-106-1-fire-science-010","火災在燃燒可以持續之狀況下，有向四周無限擴大之特性。在不受其他因素之影響下，通常其燃燒面積與經過時間之關係為何？",{"webId":217,"number":61,"stem":218,"answer":58,"indexable":20},"fire-106-1-fire-science-011","下列有關擴散火焰的敘述，何者正確？",{"webId":220,"number":65,"stem":221,"answer":38,"indexable":20},"fire-106-1-fire-science-012","凡不能與氧化合之物質均非可燃物，例如氦（He）、氖（Ne）、氬（Ar）等氣體。但氮（N2）可與氧化合，亦被視為非可燃…",{"webId":223,"number":69,"stem":224,"answer":58,"indexable":20},"fire-106-1-fire-science-013","氣體本身受到壓縮，增高溫度時，亦可發火，此稱為：",{"webId":226,"number":73,"stem":227,"answer":38,"indexable":20},"fire-106-1-fire-science-014","在乙炔氣瓶內加入丙酮以溶解乙炔氣，主要是防止那一種爆炸？",{"webId":229,"number":77,"stem":230,"answer":25,"indexable":20},"fire-106-1-fire-science-015","粉塵爆炸與可燃性氣體相同，亦須存在有「最小發火能量」始可能引起粉塵爆炸，下列有關粉塵爆炸「最小發火能量」之敘述何者錯…",{"webId":232,"number":81,"stem":233,"answer":19,"indexable":20},"fire-106-1-fire-science-016","下列有關粉塵爆炸之敘述，何者錯誤？",{"webId":235,"number":85,"stem":236,"answer":38,"indexable":20},"fire-106-1-fire-science-017","根據火場能見度（S）與消光係數（K）間之經驗公式，對於發光物體之敘述何者正確？",{"webId":238,"number":89,"stem":239,"answer":19,"indexable":20},"fire-106-1-fire-science-018","有關煙囪效應之敘述，下列何者錯誤？",{"webId":241,"number":93,"stem":242,"answer":58,"indexable":20},"fire-106-1-fire-science-019","研究火災特性時，所謂的「火載量」（Fire Load）是指：",{"webId":244,"number":97,"stem":245,"answer":38,"indexable":20},"fire-106-1-fire-science-020","某一混凝土結構之居室，長 20 公尺、寬 10 公尺、高 4 公尺。居室內之可燃物（以木材為主）總重 2000 公斤…",{"webId":247,"number":101,"stem":248,"answer":58,"indexable":20},"fire-106-1-fire-science-021","關於乙炔的性質及火災危險性，下列何者正確？",{"webId":250,"number":105,"stem":251,"answer":58,"indexable":20},"fire-106-1-fire-science-022","水的滅火效果，下列何者正確？",{"webId":253,"number":109,"stem":254,"answer":25,"indexable":20},"fire-106-1-fire-science-023","燃燒範圍是研判物質物性之重要因素，今有某液化石油氣，其成分為丙烷（C3H8 ）40%燃燒範圍為 2.4%~9.5%、…",{"webId":256,"number":113,"stem":257,"answer":38,"indexable":20},"fire-106-1-fire-science-024","假設正向煙囪效應在中性帶以上 8 m 處的壓差為 10 Pa，若建築物內、外的溫差不變，中性帶以上 20 m 處的壓…",{"webId":259,"number":117,"stem":260,"answer":58,"indexable":20},"fire-106-1-fire-science-025","依據實驗，人穿著普通作業服時，其受熱之界限值約為多少？",{"webId":262,"number":121,"stem":263,"answer":25,"indexable":20},"fire-106-1-fire-science-026","有一家用延長線，欲連接電子鍋、熱水瓶及微波爐，耗電功率分別為 550 W、1100 W 及 2200 W，請問該延長…",{"webId":265,"number":125,"stem":266,"answer":38,"indexable":20},"fire-106-1-fire-science-027","要使 1 kg 之乙炔完全燃燒，在標準狀態下，其所需之空氣容積為多少？",{"webId":268,"number":129,"stem":269,"answer":19,"indexable":20},"fire-106-1-fire-science-028","有一平板絕緣層內面溫度為 270℃，外面以熱對流方式散失到 20℃的空氣中，平板厚度為 4 cm，熱傳導係數 K=1…",{"webId":271,"number":133,"stem":272,"answer":25,"indexable":20},"fire-106-1-fire-science-029","一般而言，區劃空間火災中引發閃燃時，樓地板最低輻射熱通量值約為何？",{"webId":274,"number":137,"stem":275,"answer":25,"indexable":20},"fire-106-1-fire-science-030","依照 McCaffrey 火羽流理論，下列何者正確？",{"webId":277,"number":141,"stem":278,"answer":38,"indexable":20},"fire-106-1-fire-science-031","建築物火災時要防止火勢由外牆的窗戶向上延燒，下列改善措施何者錯誤？",{"webId":280,"number":145,"stem":281,"answer":58,"indexable":20},"fire-106-1-fire-science-032","火場能見度與煙霧消光係數有密切關係，若以煙霧的質量光學密度 Dm（m2\u002Fg）代表煙霧密度，假定在長 8m、寬 6m、…",{"webId":283,"number":149,"stem":284,"answer":58,"indexable":20},"fire-106-1-fire-science-033","設有一儲存倉庫使用混凝土及磚塊所築成，該倉庫長 10 m、寬 7 m、高 3.5 m。可燃物（以木材為主）總重 21…",{"webId":286,"number":153,"stem":287,"answer":58,"indexable":20},"fire-106-1-fire-science-034","假設建築物外部風速為 20 m\u002Fs，風壓係數為 0.6，空氣密度為 1 kg\u002Fm3，其對建築物迎風面所產生的風壓約為…",{"webId":289,"number":157,"stem":290,"answer":38,"indexable":20},"fire-106-1-fire-science-035","五層樓的建築物，每層設有特別安全梯，樓梯採正壓且加壓壓力為 35 Pa，每層特別安全梯之前室採正壓且加壓壓力為 25…",{"webId":292,"number":161,"stem":293,"answer":58,"indexable":20},"fire-106-1-fire-science-036","在一大氣壓力狀態下，假設空氣中氧（O2）之重量占整體空氣的 23%，試問 1 kg 之硫（S）完全燃燒，約需多少公斤…",{"webId":295,"number":165,"stem":296,"answer":19,"indexable":20},"fire-106-1-fire-science-037","已知門扇高 2.13 m、寬 0.91 m，把手安置在靠近邊緣 0.076 m 處，兩邊壓為 75 Pa，壓力係數 …",{"webId":298,"number":169,"stem":299,"answer":19,"indexable":20},"fire-106-1-fire-science-038","一般研究建築物室內火災行為特性時，將室內所產生的煙與熱，區分成上層區（熱區）及下層區（冷區），進而研究的模式稱為：",{"webId":301,"number":173,"stem":302,"answer":25,"indexable":20},"fire-106-1-fire-science-039","依據日本建設省建築研究所的模型實驗結果，影響閃燃時間（F.O.T.）最大的因素，不包括下列何者？",{"webId":304,"number":13,"stem":305,"answer":38,"indexable":20},"fire-106-1-fire-science-040","下列何者會造成局部電阻值增加，而成為火災發生的原因？",{"count":23,"points":179,"split":307},[117,117],{"name":309,"slug":310,"kicker":311,"count":13,"explained":13,"list":312,"essay":433},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical",[313,316,319,322,325,328,331,334,337,340,343,346,349,352,355,358,361,364,367,370,373,376,379,382,385,388,391,394,397,400,403,406,409,412,415,418,421,424,427,430],{"webId":314,"number":17,"stem":315,"answer":58,"indexable":20},"fire-106-1-water-chemical-001","依 NFPA 2001 之規定，潔淨式氣體滅火系統於一般場所之藥劑放射時間（達設計濃度 95%之時間），下列何者錯誤…",{"webId":317,"number":23,"stem":318,"answer":38,"indexable":20},"fire-106-1-water-chemical-002","依各類場所消防安全設備設置標準，下列何種場所不需設置滅火器？",{"webId":320,"number":28,"stem":321,"answer":19,"indexable":20},"fire-106-1-water-chemical-003","有關滅火器設置間距之規定，下列何者錯誤？",{"webId":323,"number":32,"stem":324,"answer":25,"indexable":20},"fire-106-1-water-chemical-004","依滅火器認可基準，大型滅火器充填乾粉時，滅火藥劑量需在多少公斤以上？",{"webId":326,"number":36,"stem":327,"answer":38,"indexable":20},"fire-106-1-water-chemical-005","某一鍋爐房之長寬高分別為 8 m、5 m 及 4 m，若設置全區放射 CO2 滅火設備，其所有開口皆可在放射前自動關…",{"webId":329,"number":41,"stem":330,"answer":58,"indexable":20},"fire-106-1-water-chemical-006","全區放射二氧化碳滅火設備進行綜合檢查時，如為低壓式儲存系統，在放射試驗時需放射多少藥劑量？",{"webId":332,"number":45,"stem":333,"answer":58,"indexable":20},"fire-106-1-water-chemical-007","依各類場所消防安全設備設置標準，二氧化碳滅火設備之藥劑放射時間，下列何者正確？",{"webId":335,"number":7,"stem":336,"answer":25,"indexable":20},"fire-106-1-water-chemical-008","乾粉滅火設備進行性能檢查時，滅火藥劑檢查注意事項中，溫度超過Ｘ℃以上，濕度超過Ｙ%以上時，應暫停檢查，Ｘ及Ｙ分別為：",{"webId":338,"number":52,"stem":339,"answer":58,"indexable":20},"fire-106-1-water-chemical-009","如無額外防止乾粉與加壓氣體分離之措施，乾粉滅火設備之配管任一部分與彎曲部分之距離，至少應為其管徑的多少倍？",{"webId":341,"number":56,"stem":342,"answer":25,"indexable":20},"fire-106-1-water-chemical-010","一汽車修理廠欲採用移動式乾粉滅火設備，則其外牆開口面積（常時開放部分）須符合下列那一規定？",{"webId":344,"number":61,"stem":345,"answer":58,"indexable":20},"fire-106-1-water-chemical-011","鹵化烴滅火設備進行性能檢查時，控制裝置之遲延裝置檢查項目，於操作啟動按鈕後至容器閥開放裝置動作，其所需時間應為：",{"webId":347,"number":65,"stem":348,"answer":25,"indexable":20},"fire-106-1-water-chemical-012","簡易自動滅火設備進行性能檢查時，其蓄壓式滅火藥劑量應與標示重量差異在何範圍以內？",{"webId":350,"number":69,"stem":351,"answer":38,"indexable":20},"fire-106-1-water-chemical-013","有關室內消防栓之放水壓力，下列何者錯誤？",{"webId":353,"number":73,"stem":354,"answer":19,"indexable":20},"fire-106-1-water-chemical-014","達顯著滅火困難之公共危險物品室外儲存場所，設置室外消防栓設備，其緊急電源應使用發電機設備或蓄電池設備，供電容量應供其…",{"webId":356,"number":77,"stem":357,"answer":19,"indexable":20},"fire-106-1-water-chemical-015","某一高度危險工作場所，其建築物外面設有 4 具室外消防栓，則其水源容量至少應為多少？",{"webId":359,"number":81,"stem":360,"answer":38,"indexable":20},"fire-106-1-water-chemical-016","自動撒水設備竣工時進行加壓試驗，下列何者正確？",{"webId":362,"number":85,"stem":363,"answer":58,"indexable":20},"fire-106-1-water-chemical-017","有關撒水頭之設置，下列敘述何者錯誤？",{"webId":365,"number":89,"stem":366,"answer":25,"indexable":20},"fire-106-1-water-chemical-018","公共危險物品等場所設置自動撒水設備時，使用密閉式撒水頭其水源容量，應在設置 X 個撒水頭繼續放水 Y 分鐘之水量以上…",{"webId":368,"number":93,"stem":369,"answer":58,"indexable":20},"fire-106-1-water-chemical-019","進行密閉濕式撒水設備綜合檢查時，末端查驗管之放水壓力應在那個範圍？",{"webId":371,"number":97,"stem":372,"answer":19,"indexable":20},"fire-106-1-water-chemical-020","水霧滅火設備之加壓送水裝置使用消防幫浦時，其出水量及出水壓力，下列敘述何者錯誤？",{"webId":374,"number":101,"stem":375,"answer":25,"indexable":20},"fire-106-1-water-chemical-021","裝置水霧滅火設備之室內停車空間，其排水設備應符合之規定，下列何者錯誤？",{"webId":377,"number":105,"stem":378,"answer":19,"indexable":20},"fire-106-1-water-chemical-022","下列那一泡沫滅火設備之泡沫濃度，不符泡沫原液與水混合使用濃度之規定？",{"webId":380,"number":109,"stem":381,"answer":19,"indexable":20},"fire-106-1-water-chemical-023","泡沫滅火設備進行綜合檢查時，有關蛋白質泡沫滅火藥劑之發泡倍率至少應為何？",{"webId":383,"number":113,"stem":384,"answer":19,"indexable":20},"fire-106-1-water-chemical-024","公共危險物品等場所設置移動式泡沫滅火設備時，其水源容量與放水量之規定，下列何者錯誤？",{"webId":386,"number":117,"stem":387,"answer":58,"indexable":20},"fire-106-1-water-chemical-025","某一防護對象物長寬高分別為 5 公尺、4 公尺及 1 公尺，若以高發泡局部放射泡沫滅火系統進行防護，依各類場所消防安…",{"webId":389,"number":121,"stem":390,"answer":25,"indexable":20},"fire-106-1-water-chemical-026","消防專用蓄水池至建築物各部分之水平距離，應在多少公尺以下？",{"webId":392,"number":125,"stem":393,"answer":19,"indexable":20},"fire-106-1-water-chemical-027","依各類場所消防安全設備設置標準，連結送水管之出水口設置，下列敘述何者錯誤？",{"webId":395,"number":129,"stem":396,"answer":38,"indexable":20},"fire-106-1-water-chemical-028","末端查驗管量測到的壓力為何？",{"webId":398,"number":133,"stem":399,"answer":19,"indexable":20},"fire-106-1-water-chemical-029","10 型乾粉滅火器乾粉充填量約為多少公斤重？",{"webId":401,"number":137,"stem":402,"answer":25,"indexable":20},"fire-106-1-water-chemical-030","第一種感度之撒水頭其反應時間指數（RTI）應小於多少 (ms) ？",{"webId":404,"number":141,"stem":405,"answer":58,"indexable":20},"fire-106-1-water-chemical-031","B-30 乾粉滅火器可以滅火之油盤面積為多少平方公尺？",{"webId":407,"number":145,"stem":408,"answer":19,"indexable":20},"fire-106-1-water-chemical-032","二氧化碳全區放射方式之安全裝置，啟動裝置開關或拉桿開始動作至儲存容器之容器閥開啟，設有多少秒以上之遲延裝置？",{"webId":410,"number":149,"stem":411,"answer":38,"indexable":20},"fire-106-1-water-chemical-033","二氧化碳局部放射方式依規定所核算之滅火藥劑量，應於多少秒內全部放射完畢？",{"webId":413,"number":153,"stem":414,"answer":25,"indexable":20},"fire-106-1-water-chemical-034","第一種乾粉滅火藥劑，全區放射方式所需滅火藥劑量為多少 kg\u002Fm ？",{"webId":416,"number":157,"stem":417,"answer":58,"indexable":20},"fire-106-1-water-chemical-035","乾式比濕式系統的撒水頭數量應追加百分之多少？",{"webId":419,"number":161,"stem":420,"answer":38,"indexable":20},"fire-106-1-water-chemical-036","低壓式二氧化碳噴頭之放射壓力為每平方公分多少公斤以上？",{"webId":422,"number":165,"stem":423,"answer":58,"indexable":20},"fire-106-1-water-chemical-037","消防幫浦之全閉揚程應為性能曲線上全揚程之百分之多少以下，方符合檢修基準要求？",{"webId":425,"number":169,"stem":426,"answer":19,"indexable":20},"fire-106-1-water-chemical-038","乾粉全區放射所核算之滅火藥劑量須於幾秒內放射完畢？",{"webId":428,"number":173,"stem":429,"answer":19,"indexable":20},"fire-106-1-water-chemical-039","泡沫滅火設備使用低發泡水成膜泡沫液，其泡沫 25%還原時間應在多少分鐘以上？",{"webId":431,"number":13,"stem":432,"answer":19,"indexable":20},"fire-106-1-water-chemical-040","有一長 15 公尺、寬 12 公尺及高 3 公尺之密閉空間裝置二氧化碳滅火設備，假設空氣中氧氣之體積百分率濃度為 2…",{"count":23,"points":179,"split":434},[117,117],{"name":436,"slug":437,"kicker":438,"count":13,"explained":13,"list":439,"essay":560},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress",[440,443,446,449,452,455,458,461,464,467,470,473,476,479,482,485,488,491,494,497,500,503,506,509,512,515,518,521,524,527,530,533,536,539,542,545,548,551,554,557],{"webId":441,"number":17,"stem":442,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-001","某一 KTV 視聽歌唱場所設於大樓地下層，依規定樓地板面積如合計超過多少，應設置瓦斯漏氣火警自動警報設備？",{"webId":444,"number":23,"stem":445,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-002","對於消防安全設備緊急供電系統之配線之規定，下列何者正確？",{"webId":447,"number":28,"stem":448,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-003","裝設緊急廣播設備之建築物之規定，下列何者錯誤？",{"webId":450,"number":32,"stem":451,"answer":25,"indexable":20},"fire-106-1-alarm-evacuation-004","依各類場所消防安全設備檢修及申報作業基準規定，1 種光電式局限型偵煙探測器於使用加煙試驗器確認動作之時間，加煙後至動…",{"webId":453,"number":36,"stem":454,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-005","依各類場所消防安全設備設置標準規定，下列何種場所如設置高感度密閉式撒水頭自動撒水設備，得免設火警自動警報設備？",{"webId":456,"number":41,"stem":457,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-006","樓梯、斜坡通道、昇降機之昇降路及管道間等場所，其頂層相差在二層以下、水平距離多少範圍內，視為一火警分區？",{"webId":459,"number":45,"stem":460,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-007","如設置救助袋做為避難器具，下列敘述何者錯誤？",{"webId":462,"number":7,"stem":463,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-008","天花板設排氣口或回風口時，偵煙式探測器應裝置於排氣口或回風口周圍多少距離範圍內？",{"webId":465,"number":52,"stem":466,"answer":25,"indexable":20},"fire-106-1-alarm-evacuation-009","差動式分布型探測器為熱電偶式時，熱電偶應裝置在裝置面下方多少公分範圍內？",{"webId":468,"number":56,"stem":469,"answer":25,"indexable":20},"fire-106-1-alarm-evacuation-010","緩降機設置周圍為避免有操作障礙，因此限制必要操作面積為 M 平方公尺以上（不含避難器具所占面積），但邊長應為 N 公…",{"webId":471,"number":61,"stem":472,"answer":25,"indexable":20},"fire-106-1-alarm-evacuation-011","Ｐ型受信總機採用數個分區共用一公用線方式配線時，該公用線供應之分區數，不得超過 X 個。受信總機之探測器回路電阻，應…",{"webId":474,"number":65,"stem":475,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-012","依據緊急照明燈認可基準進行充電試驗時，蓄電池電壓降達額定電壓多少以內時，需能自動充電？",{"webId":477,"number":69,"stem":478,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-013","集合住宅計算收容人數以設置避難器具時，每戶收容人數以多少人計算？",{"webId":480,"number":73,"stem":481,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-014","依各類場所消防安全設備檢修及申報作業基準規定，火警自動警報設備之受信總機前應確保多少公尺以上空間以進行檢查及操作使用…",{"webId":483,"number":77,"stem":484,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-015","依緩降機認可基準規定，緩降機之最大使用載重，應在最大使用人數乘以 W 所得數值以上。下述 W 值何者正確？",{"webId":486,"number":81,"stem":487,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-016","瓦斯漏氣火警自動警報設備裝置於瓦斯對空氣之比重未滿一之建築物室內時，檢知器設置位置應距瓦斯燃燒器具或瓦斯導管貫穿牆壁…",{"webId":489,"number":85,"stem":490,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-017","檢查緩降機性能時，有關常溫下降試驗之判定中，緩降機最大下降速度應在多少以內？",{"webId":492,"number":89,"stem":493,"answer":25,"indexable":20},"fire-106-1-alarm-evacuation-018","依各類場所消防安全設備檢修及申報作業基準規定，火焰探測器以動作試驗器確認探測器之動作應在多少時間內方為合格？",{"webId":495,"number":93,"stem":496,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-019","一居室設置於地上層，該樓層亦非為無開口樓層，自內部任一點易於識別主要出入口，主要出入口之步行距離在多少以下者，得免設…",{"webId":498,"number":97,"stem":499,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-020","差動式探測器之動作原理為感應火場中何種參數？",{"webId":501,"number":101,"stem":502,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-021","下列消防安全設備緊急供電系統之配線，何者需施予耐燃保護？",{"webId":504,"number":105,"stem":505,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-022","依出口標示燈及避難方向指示燈認可基準規定，燈具附有起動器者，應在多少時間內點燈？",{"webId":507,"number":109,"stem":508,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-023","一大樓內部某樓層設有不得供避難、通行及搬運以外用途之防火構造架空走廊一座，該樓層可依法減設多少具避難器具？",{"webId":510,"number":113,"stem":511,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-024","依各類場所消防安全設備設置標準規定，特別安全梯或緊急昇降機間排煙室之排煙設備設置排煙、進風風管時，下列何者有誤？",{"webId":513,"number":117,"stem":514,"answer":25,"indexable":20},"fire-106-1-alarm-evacuation-025","依緊急照明燈認可基準規定，內置電池型緊急電源供電照明時間應維持 1.5 小時以上（供緊急照明燈總數）後，其蓄電池電壓…",{"webId":516,"number":121,"stem":517,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-026","樓梯或斜坡通道以外之場所，廣播區域之殘響時間在 3 秒以上時，揚聲器之裝設需符合 r = 3 \u002F 4 QSα\u002Fπ (…",{"webId":519,"number":125,"stem":520,"answer":25,"indexable":20},"fire-106-1-alarm-evacuation-027","避難方向指示燈設於樓梯或坡道者，在樓梯級面或坡道表面之照度，應在多少勒克司（lx）以上？",{"webId":522,"number":129,"stem":523,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-028","大型建築物警報設備使用許多中繼器來連結探測器與受信總機，但下列何者不是警報設備中繼器主要功能？",{"webId":525,"number":133,"stem":526,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-029","瓦斯濃度達到警報濃度值後，其濃度仍繼續存在，即發出警報，但瓦斯洩漏濃度越高，則警報延遲動作時間越短，此種檢知瓦斯之警…",{"webId":528,"number":137,"stem":529,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-030","在某飯店檢查瓦斯漏氣火警自動警報設備時，何項試驗必須切換成緊急電源之狀態？",{"webId":531,"number":141,"stem":532,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-031","在某飯店檢查瓦斯漏氣火警自動警報設備，進行檢知器之性能檢查時，發現同一個檢知回路上裝設有 18 個瓦斯漏氣檢知器，至…",{"webId":534,"number":145,"stem":535,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-032","針對瓦斯漏氣火警自動警報設備進行性能檢查，使用噪音計進行瓦斯漏氣檢知區域警報裝置之音量檢測時，距離警報裝置 1 公尺…",{"webId":537,"number":149,"stem":538,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-033","針對某百貨公司美食街進行檢修，下列何項試驗必須使用加瓦斯試驗器，使兩個回路之任一檢知器（各回路一個）同時動作，以確認…",{"webId":540,"number":153,"stem":541,"answer":25,"indexable":20},"fire-106-1-alarm-evacuation-034","在裝設定溫式感知線型探測器場所，進行回路合成阻抗試驗時，會使用下列何種檢查儀器？",{"webId":543,"number":157,"stem":544,"answer":19,"indexable":20},"fire-106-1-alarm-evacuation-035","執行檢修時，在室溫 15℃狀態下，使用加熱試驗器進行差動式局限型第二種探測器之性能檢查時，其動作時間應在多少秒內方為…",{"webId":546,"number":161,"stem":547,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-036","很多工程裝設局限型探測器時多緊鄰天花板上出風口，造成失效或延遲警報，因此，施工時依規定裝設位置應距該出風口多少公尺以…",{"webId":549,"number":165,"stem":550,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-037","為避免探測死角，在安裝光電式分離型探測器時，其受光器及送光器應設在距其背部牆壁多少公分範圍內？",{"webId":552,"number":169,"stem":553,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-038","依各類場所消防安全設備設置標準規定，避難指標設於出入口裝設應距樓地板面的高度要求為多少？",{"webId":555,"number":173,"stem":556,"answer":38,"indexable":20},"fire-106-1-alarm-evacuation-039","具有效採光，且直接面向室外之通道或走廊居室得免設緊急照明；所謂有效採光面積應達該居室樓地板面積多少比率方得免設？",{"webId":558,"number":13,"stem":559,"answer":58,"indexable":20},"fire-106-1-alarm-evacuation-040","有關出口標示燈具閃滅或音聲引導功能者，依規定下列何者錯誤？",{"count":23,"points":179,"split":561},[117,117],1785123154552]