[{"data":1,"prerenderedAt":563},["ShallowReactive",2],{"exam-109-1":3},{"ys":4,"year":5,"total":6,"essayTotal":7,"subjects":8},"109-1",109,160,8,[9,181,309,436],{"name":10,"slug":11,"kicker":12,"count":13,"explained":13,"list":14,"essay":178},"消防法規概要","fire-law","消防法規 · Fire Code",40,[15,21,26,31,36,40,44,48,51,55,59,63,67,71,75,79,83,87,91,95,99,103,107,111,115,119,123,127,131,135,139,143,147,151,155,159,163,167,171,175],{"webId":16,"number":17,"stem":18,"answer":19,"indexable":20},"fire-109-1-fire-law-001",1,"依消防法、消防法施行細則之規定，有關一定規模以上供公眾使用建築物，下列敘述何者正確？","C",true,{"webId":22,"number":23,"stem":24,"answer":25,"indexable":20},"fire-109-1-fire-law-002",2,"依消防法之規定，得逕處其管理權人罰鍰之違法行為，下列敘述何者正確？","D",{"webId":27,"number":28,"stem":29,"answer":30,"indexable":20},"fire-109-1-fire-law-003",3,"依消防法、消防法施行細則之規定，有關消防防護計畫應包括事項，下列敘述何者正確？","A",{"webId":32,"number":33,"stem":34,"answer":35,"indexable":20},"fire-109-1-fire-law-004",4,"依消防法施行細則之規定，針對消防安全設備施工中須經試驗或勘驗事項之查核，並製作紀錄是屬於下列那個項目之內容？","B",{"webId":37,"number":38,"stem":39,"answer":25,"indexable":20},"fire-109-1-fire-law-005",5,"依消防設備師及消防設備士管理辦法之規定，直轄市、縣（市）之消防設備師或消防設備士達多少人以上者，得組織直轄市、縣（市…",{"webId":41,"number":42,"stem":43,"answer":35,"indexable":20},"fire-109-1-fire-law-006",6,"依消防設備師及消防設備士管理辦法之規定，如通過消防設備士考試，取得證書日起每 3 年應接受講習 1 次或取得累計積分…",{"webId":45,"number":46,"stem":47,"answer":19,"indexable":20},"fire-109-1-fire-law-007",7,"依消防安全設備檢修專業機構管理辦法之規定，成立消防安全設備檢修專業機構，必須聘僱多少專技人員？",{"webId":49,"number":7,"stem":50,"answer":35,"indexable":20},"fire-109-1-fire-law-008","依消防安全設備檢修專業機構管理辦法之規定，消防安全設備檢修專業機構所屬消防設備師或消防設備士檢修不實經裁罰達 5 件…",{"webId":52,"number":53,"stem":54,"answer":30,"indexable":20},"fire-109-1-fire-law-009",9,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關地下儲槽場所位置、構造及設備之規定，下列敘…",{"webId":56,"number":57,"stem":58,"answer":35,"indexable":20},"fire-109-1-fire-law-010",10,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，室內儲槽場所之儲槽專用室出入口，應設置多…",{"webId":60,"number":61,"stem":62,"answer":35,"indexable":20},"fire-109-1-fire-law-011",11,"依各類場所消防安全設備設置標準之規定，下列那一種火警探測器不適合裝設在麵粉廠灰塵會大量滯留的場所？",{"webId":64,"number":65,"stem":66,"answer":19,"indexable":20},"fire-109-1-fire-law-012",12,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關於供作六類物品製造場所或一般處理場所使用之…",{"webId":68,"number":69,"stem":70,"answer":35,"indexable":20},"fire-109-1-fire-law-013",13,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，儲存倉庫應為一層建築物，其高度不得超過 …",{"webId":72,"number":73,"stem":74,"answer":19,"indexable":20},"fire-109-1-fire-law-014",14,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，關於可燃性高壓氣體儲存場所構造、設備及安全管理…",{"webId":76,"number":77,"stem":78,"answer":30,"indexable":20},"fire-109-1-fire-law-015",15,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關販賣場所之規定，下列敘述何者正確？",{"webId":80,"number":81,"stem":82,"answer":35,"indexable":20},"fire-109-1-fire-law-016",16,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，一般瓦斯行存放多少公斤以上液化石油氣，應…",{"webId":84,"number":85,"stem":86,"answer":30,"indexable":20},"fire-109-1-fire-law-017",17,"依防火牆及防火水幕設置基準之規定，防火水幕之防護高度在 10 公尺以下時，其每公尺水幕長度放水量應在每分鐘多少公升以…",{"webId":88,"number":89,"stem":90,"answer":19,"indexable":20},"fire-109-1-fire-law-018",18,"有一固態酒精儲槽水平剖面半徑為 10 公尺，依防火牆及防火水幕設置基準，其假想火面高度應為多少公尺？",{"webId":92,"number":93,"stem":94,"answer":25,"indexable":20},"fire-109-1-fire-law-019",19,"依可燃性高壓氣體儲存場所防爆牆設置基準之規定，防爆牆長度應超過設置方位儲存場所建築物牆面長度，其牆腳與儲存場所建築物…",{"webId":96,"number":97,"stem":98,"answer":19,"indexable":20},"fire-109-1-fire-law-020",20,"依可燃性高壓氣體儲存場所防護牆設置基準之規定，下列敘述何者正確？",{"webId":100,"number":101,"stem":102,"answer":30,"indexable":20},"fire-109-1-fire-law-021",21,"依各類場所消防安全設備設置標準，有關使用密閉式撒水頭自動撒水設備末端查驗閥之規定，下列敘述何者正確？",{"webId":104,"number":105,"stem":106,"answer":35,"indexable":20},"fire-109-1-fire-law-022",22,"依各類場所消防安全設備設置標準之規定，二氧化碳滅火設備採全區放射方式時，啟動裝置開關或拉桿開始動作至儲存容器之容器閥…",{"webId":108,"number":109,"stem":110,"answer":25,"indexable":20},"fire-109-1-fire-law-023",23,"依各類場所消防安全設備設置標準，有關一一九火災通報裝置設置之規定，下列敘述何者正確？",{"webId":112,"number":113,"stem":114,"answer":19,"indexable":20},"fire-109-1-fire-law-024",24,"依各類場所消防安全設備設置標準之規定，有一容納超過 300 人老人福利機構餐廳，其樓地板面積在多少平方公尺以上，廚房…",{"webId":116,"number":117,"stem":118,"answer":19,"indexable":20},"fire-109-1-fire-law-025",25,"依各類場所消防安全設備設置標準之規定，面積 400 坪的知名餐廳，所設置滅火器核算之最低滅火效能值應為多少？",{"webId":120,"number":121,"stem":122,"answer":35,"indexable":20},"fire-109-1-fire-law-026",26,"原有照護思覺失調患者的康復之家想增設自動滅火設備，如採用小區劃型撒水頭（以第一種感度為限），依各類場所消防安全設備設…",{"webId":124,"number":125,"stem":126,"answer":19,"indexable":20},"fire-109-1-fire-law-027",27,"有一 500 平方公尺地下停車場，採水霧滅火設備，依各類場所消防安全設備設置標準，其水源容量應保持多少立方公尺以上？",{"webId":128,"number":129,"stem":130,"answer":30,"indexable":20},"fire-109-1-fire-law-028",28,"依各類場所消防安全設備設置標準，有關裝設瓦斯漏氣火警自動警報設備之規定，下列敘述何者錯誤？",{"webId":132,"number":133,"stem":134,"answer":19,"indexable":20},"fire-109-1-fire-law-029",29,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，有關幫浦性能之規定，全閉揚程應為性能曲線上全揚程之多少以下？",{"webId":136,"number":137,"stem":138,"answer":30,"indexable":20},"fire-109-1-fire-law-030",30,"依各類場所消防安全設備檢修及申報作業基準，有關避難器具外觀檢查之規定，緩降機下降空間之判定，在無其他突出物干擾的情境…",{"webId":140,"number":141,"stem":142,"answer":35,"indexable":20},"fire-109-1-fire-law-031",31,"依各類場所消防安全設備設置標準，有關泡沫原液儲存量、泡沫原液與水混合使用濃度之規定，下列敘述何者正確？",{"webId":144,"number":145,"stem":146,"answer":25,"indexable":20},"fire-109-1-fire-law-032",32,"依各類場所消防安全設備檢修及申報作業基準，有關滅火器外觀檢查之規定，滅火器本體上端與樓地板面之距離，18 公斤以上者…",{"webId":148,"number":149,"stem":150,"answer":19,"indexable":20},"fire-109-1-fire-law-033",33,"依各類場所消防安全設備檢修及申報作業基準之規定，各類場所之管理權人應委託檢修專業機構或消防法第 7 條規定之人員辦理…",{"webId":152,"number":153,"stem":154,"answer":35,"indexable":20},"fire-109-1-fire-law-034",34,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，有關幫浦性能之規定，幫浦所消耗之動力，在額定出水量 150%時，其軸…",{"webId":156,"number":157,"stem":158,"answer":35,"indexable":20},"fire-109-1-fire-law-035",35,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，裝設消防撒水幫浦，設計水量為 600 公升\u002F分，其設計揚程為 …",{"webId":160,"number":161,"stem":162,"answer":35,"indexable":20},"fire-109-1-fire-law-036",36,"依避難器具支固器具及固定部之結構、強度計算及施工方法之規定，裝置避難器具固定部材料，使用直徑 1 公分錨定螺栓，設定…",{"webId":164,"number":165,"stem":166,"answer":30,"indexable":20},"fire-109-1-fire-law-037",37,"依建築技術規則建築設計施工編之定義，每層陽臺面積之和，以不超過建築面積多少為限？其未達 8 平方公尺者，得建築 8 …",{"webId":168,"number":169,"stem":170,"answer":30,"indexable":20},"fire-109-1-fire-law-038",38,"依建築技術規則建築設計施工編之定義，經主管機關認可後，下列何者屬「防火設備」？",{"webId":172,"number":173,"stem":174,"answer":30,"indexable":20},"fire-109-1-fire-law-039",39,"依各類場所消防安全設備設置標準之規定，以防護區域每平方公尺每分鐘放水量來看，儲存可燃物場所設置放水型撒水頭是一般場所…",{"webId":176,"number":13,"stem":177,"answer":35,"indexable":20},"fire-109-1-fire-law-040","依建築技術規則建築設計施工編之規定，閣樓樓地板面積占該建築物建築面積多少以上時，視為另一樓層？",{"count":23,"points":179,"split":180},50,[117,117],{"name":182,"slug":183,"kicker":184,"count":13,"explained":173,"list":185,"essay":307},"火災學概要","fire-science","火災學 · Fire Science",[186,189,192,195,198,201,204,207,210,214,217,220,223,226,229,232,235,238,241,244,247,250,253,256,259,262,265,268,271,274,277,280,283,286,289,292,295,298,301,304],{"webId":187,"number":17,"stem":188,"answer":35,"indexable":20},"fire-109-1-fire-science-001","已知辛烷的燃燒下限為 0.92（vol%），根據 Burgess-Wheeler 定理其燃燒熱約為多少？",{"webId":190,"number":23,"stem":191,"answer":19,"indexable":20},"fire-109-1-fire-science-002","三個面積分別為 0.20 m ，0.40 m ，0.60 m 之開口相互串聯時，其等效流動面積為何？",{"webId":193,"number":28,"stem":194,"answer":25,"indexable":20},"fire-109-1-fire-science-003","依用戶用電設備設置規則及建築技術規則，下列避雷設置敘述何者錯誤？",{"webId":196,"number":33,"stem":197,"answer":35,"indexable":20},"fire-109-1-fire-science-004","某一火災成長至 2,000 kW 所需時間為 400 秒，請問該火災屬何種成長性火災？[Q：釋熱率（MW）； 1\u002F2…",{"webId":199,"number":38,"stem":200,"answer":19,"indexable":20},"fire-109-1-fire-science-005","下列有關二氧化碳（CO2）滅火劑之敘述，何者錯誤？",{"webId":202,"number":42,"stem":203,"answer":25,"indexable":20},"fire-109-1-fire-science-006","某次閃電的過程中，雲的底部和地面之間，電壓高達 1 千萬伏特，並在約 0.02 秒內輸送 20 庫倫的電量至地面。下…",{"webId":205,"number":46,"stem":206,"answer":35,"indexable":20},"fire-109-1-fire-science-007","進入石化工廠，車輛會被要求在排氣管加裝滅焰器（flame arrester）以避免火災爆炸之發生，加裝該措施防制火災…",{"webId":208,"number":7,"stem":209,"answer":19,"indexable":20},"fire-109-1-fire-science-008","1 度電為 1,000 瓦．小時（1 kWh），試問 1 度電約等同多少千卡（kcal）？",{"webId":211,"number":53,"stem":212,"answer":19,"indexable":213},"fire-109-1-fire-science-009","如下圖所示，在已接地之電路上，有甲、乙、丙 3 個可為通路或斷路的接點。若人站在地上，而手碰觸到金屬外殼形成通路，則…",false,{"webId":215,"number":57,"stem":216,"answer":25,"indexable":20},"fire-109-1-fire-science-010","有水之場所的插頭應加裝何種裝置以防止感電發生？",{"webId":218,"number":61,"stem":219,"answer":35,"indexable":20},"fire-109-1-fire-science-011","某一線徑 2.0 m\u002Fm 之電線 1 km 長之電阻值為 5.657 Ω，熱阻抗為 378。若周遭溫度為 20℃，當…",{"webId":221,"number":65,"stem":222,"answer":35,"indexable":20},"fire-109-1-fire-science-012","下列常見之乾粉滅火藥劑敘述何者正確？",{"webId":224,"number":69,"stem":225,"answer":19,"indexable":20},"fire-109-1-fire-science-013","下列的滅火設備，何者屬於窒息法滅火原理？",{"webId":227,"number":73,"stem":228,"answer":19,"indexable":20},"fire-109-1-fire-science-014","火場溫度隨燃燒時間而逐漸升高，其空氣亦漸膨脹，空氣由外界流入該起火房間，同時熱煙霧也會從該起火房間流出。若忽略燃燒分…",{"webId":230,"number":77,"stem":231,"answer":35,"indexable":20},"fire-109-1-fire-science-015","下列海龍替代滅火藥劑，何者之化學組成為五氟乙烷？",{"webId":233,"number":81,"stem":234,"answer":25,"indexable":20},"fire-109-1-fire-science-016","假設建築物外部風速為 10 m\u002Fs，風壓係數為 0.6，空氣密度為 1.0 kg\u002Fm3，其對迎風面建築物所產生的風壓…",{"webId":236,"number":85,"stem":237,"answer":35,"indexable":20},"fire-109-1-fire-science-017","T.N.T.炸藥化學名稱為三硝基甲苯（Trinitrotolene，C7H5N3O6），俗稱黃色炸藥，試問其氧平衡（…",{"webId":239,"number":89,"stem":240,"answer":19,"indexable":20},"fire-109-1-fire-science-018","化學災害搶救程序 HAZMAT 之說明，下列何者正確？",{"webId":242,"number":93,"stem":243,"answer":30,"indexable":20},"fire-109-1-fire-science-019","若一物體的溫度為 327℃，輻射率（ Emissivity）為 0.1，已知史蒂芬–波茲曼常數為 5.67×10-8…",{"webId":245,"number":97,"stem":246,"answer":30,"indexable":20},"fire-109-1-fire-science-020","某研究院之廠區引發爆燃事件之推進劑，其內含過氯酸鹽類，試問其為公共危險物品中第幾類物質？",{"webId":248,"number":101,"stem":249,"answer":35,"indexable":20},"fire-109-1-fire-science-021","混合氣體由 A、B、C 三種氣體組成，混合時組成氣體不進行反應，且燃燒無催化作用，其中各氣體之混合濃度中，A 氣體占…",{"webId":251,"number":105,"stem":252,"answer":19,"indexable":20},"fire-109-1-fire-science-022","預防過氧化丁酮之火災爆炸時，下列何種原則正確？",{"webId":254,"number":109,"stem":255,"answer":35,"indexable":20},"fire-109-1-fire-science-023","若要看清某一物體，該物體與其背景間有一定之對比度。對比度之計算：C=(B\u002FB0)-1，有關對比度下列何者正確？",{"webId":257,"number":113,"stem":258,"answer":35,"indexable":20},"fire-109-1-fire-science-024","在古蹟及歷史建築物火災風險評估指標中，有關防火因應措施安全評估項目中，不包括下列何項？",{"webId":260,"number":117,"stem":261,"answer":19,"indexable":20},"fire-109-1-fire-science-025","有關火羽流的敘述，下列何者錯誤？",{"webId":263,"number":121,"stem":264,"answer":25,"indexable":20},"fire-109-1-fire-science-026","閃燃發生時間之影響因素中，通風為其中之一項，請問：A0(H0)1\u002F2 的通風因子公式中，A0 與 H0 各代表何意？",{"webId":266,"number":125,"stem":267,"answer":30,"indexable":20},"fire-109-1-fire-science-027","下列有關泡沫滅火劑，何者敘述正確？",{"webId":269,"number":129,"stem":270,"answer":19,"indexable":20},"fire-109-1-fire-science-028","森林火災的種類與敘述，下列何者正確？",{"webId":272,"number":133,"stem":273,"answer":19,"indexable":20},"fire-109-1-fire-science-029","有關防火塗料敘述，下列何者錯誤？",{"webId":275,"number":137,"stem":276,"answer":19,"indexable":20},"fire-109-1-fire-science-030","海龍替代滅火藥劑中，下列何者在大氣之滯留時間最久？",{"webId":278,"number":141,"stem":279,"answer":25,"indexable":20},"fire-109-1-fire-science-031","建築物火災在閃燃發生後之全盛期火災的特性，不包括下列何者？",{"webId":281,"number":145,"stem":282,"answer":30,"indexable":20},"fire-109-1-fire-science-032","已知天花板噴流溫度攝氏 135℃，天花板噴流速度 1.8 m\u002Fs，環境初始溫度 20℃，感知撒水頭作動溫度攝氏 72…",{"webId":284,"number":149,"stem":285,"answer":19,"indexable":20},"fire-109-1-fire-science-033","乙醇之燃燒化學反應式為下列何者？ 9 3",{"webId":287,"number":153,"stem":288,"answer":35,"indexable":20},"fire-109-1-fire-science-034","BLEVE 的發生，下列敘述何者錯誤？",{"webId":290,"number":157,"stem":291,"answer":35,"indexable":20},"fire-109-1-fire-science-035","有關引火性液體的敘述，下列何者正確？",{"webId":293,"number":161,"stem":294,"answer":19,"indexable":20},"fire-109-1-fire-science-036","房間的體積為 V=6 m×5 m×3 m，其中 O2 占 0.21 V，請問至少要加入多少公升（L）的 CO2 讓燃…",{"webId":296,"number":165,"stem":297,"answer":25,"indexable":20},"fire-109-1-fire-science-037","D 類火災可使用的滅火劑，何者適合？",{"webId":299,"number":169,"stem":300,"answer":25,"indexable":20},"fire-109-1-fire-science-038","在橡膠中混入碳黑所製成的產品可防止人體帶靜電，其防止靜電發生的方法為？",{"webId":302,"number":173,"stem":303,"answer":30,"indexable":20},"fire-109-1-fire-science-039","帶電物體或其附近之接地體，有突出部分或刃狀部分時，在該等前端近旁，所出現之微弱發光放電，此現象稱為？",{"webId":305,"number":13,"stem":306,"answer":35,"indexable":20},"fire-109-1-fire-science-040","有關預混合火焰特性，下列敘述何者錯誤？",{"count":23,"points":179,"split":308},[117,117],{"name":310,"slug":311,"kicker":312,"count":13,"explained":13,"list":313,"essay":434},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical",[314,317,320,323,326,329,332,335,338,341,344,347,350,353,356,359,362,365,368,371,374,377,380,383,386,389,392,395,398,401,404,407,410,413,416,419,422,425,428,431],{"webId":315,"number":17,"stem":316,"answer":25,"indexable":20},"fire-109-1-water-chemical-001","下列場所何者未達依法應設置滅火器之條件？",{"webId":318,"number":23,"stem":319,"answer":25,"indexable":20},"fire-109-1-water-chemical-002","某地下一層、地上七層建築物，地下層為室內停車空間，面積 200 平方公尺，一至七層為集合住宅，各層面積 100 平方…",{"webId":321,"number":28,"stem":322,"answer":19,"indexable":20},"fire-109-1-water-chemical-003","某建築物之室內、外消防栓、自動撒水及水霧滅火等設備配管採連通設計並共用消防幫浦，其共用消防幫浦之出水量和全揚程之要求…",{"webId":324,"number":33,"stem":325,"answer":19,"indexable":20},"fire-109-1-water-chemical-004","供集會堂使用之舞臺，應設置何種自動撒水設備？",{"webId":327,"number":38,"stem":328,"answer":19,"indexable":20},"fire-109-1-water-chemical-005","某電信機械室設置二氧化碳全區放射滅火設備，其核算之滅火藥劑量應於多少時間內全部放射完畢？",{"webId":330,"number":42,"stem":331,"answer":30,"indexable":20},"fire-109-1-water-chemical-006","消防幫浦設置呼水槽時，防止水溫上升用排放裝置之標稱口徑不得小於多少毫米？",{"webId":333,"number":46,"stem":334,"answer":19,"indexable":20},"fire-109-1-water-chemical-007","下列何者非為消防機關辦理建築物消防安全設備審查及查驗作業基準規定，申請消防專用蓄水池查驗應檢附安裝施工測試佐證資料？",{"webId":336,"number":7,"stem":337,"answer":19,"indexable":20},"fire-109-1-water-chemical-008","預動式自動撒水設備竣工測試進行放水試驗時，開放末端查驗閥後，應在多久時間內正常放水？",{"webId":339,"number":53,"stem":340,"answer":19,"indexable":20},"fire-109-1-water-chemical-009","進行低發泡水成膜泡沫放射試驗時，其 25%還原時間應在多久時間以上？",{"webId":342,"number":57,"stem":343,"answer":30,"indexable":20},"fire-109-1-water-chemical-010","全區放射方式之二氧化碳滅火設備，應設置從啟動裝置動作至二氧化碳放出時間至少多久的遲延裝置？",{"webId":345,"number":61,"stem":346,"answer":19,"indexable":20},"fire-109-1-water-chemical-011","乾粉滅火設備之緊急電源應為發電機設備或蓄電池設備，其容量應能使該設備有效動作多少時間以上？",{"webId":348,"number":65,"stem":349,"answer":25,"indexable":20},"fire-109-1-water-chemical-012","消防水系統設置呼水裝置時，其溢水用排水管口徑應在多少尺寸以上？",{"webId":351,"number":69,"stem":352,"answer":30,"indexable":20},"fire-109-1-water-chemical-013","乾粉滅火設備設置啟動用氣體容器時，其容器之內容積應有多少以上？",{"webId":354,"number":73,"stem":355,"answer":35,"indexable":20},"fire-109-1-water-chemical-014","測量室內消防栓瞄子直線放水之壓力時，應將壓力表之進水口，放置於瞄子前端多少距離處，讀取壓力表的指示值？",{"webId":357,"number":77,"stem":358,"answer":25,"indexable":20},"fire-109-1-water-chemical-015","公共危險物品室外儲槽場所設置射水設備時，測試之放水壓力應在多少以上？",{"webId":360,"number":81,"stem":361,"answer":35,"indexable":20},"fire-109-1-water-chemical-016","製造年份超過 10 年之室內消防栓水帶進行耐水壓試驗時，施以 7 kgf\u002Fcm²以上水壓試驗多久時間，始得視為合格可…",{"webId":363,"number":85,"stem":364,"answer":35,"indexable":20},"fire-109-1-water-chemical-017","某爆竹煙火儲存場所設置室外消防栓設備共 8 具，進行設備檢修綜合檢查時，至少應選擇配管上最遠最高處多少數量之室外消防…",{"webId":366,"number":89,"stem":367,"answer":19,"indexable":20},"fire-109-1-water-chemical-018","移動式泡沫滅火設備進行綜合檢查作業時，發泡倍率應在幾倍以上？",{"webId":369,"number":93,"stem":370,"answer":19,"indexable":20},"fire-109-1-water-chemical-019","某室內停車空間設置低發泡固定式泡沫滅火設備，每次檢修作業時，應選擇全部放射區域數多少比例以上之放射區域進行逐區放水試…",{"webId":372,"number":97,"stem":373,"answer":25,"indexable":20},"fire-109-1-water-chemical-020","用於防護電氣設施之水霧滅火設備進行放水試驗時，最末端放射區域全部水霧噴頭之放水壓力均應能達到多少壓力以上？",{"webId":375,"number":101,"stem":376,"answer":30,"indexable":20},"fire-109-1-water-chemical-021","室內消防栓中之減水警報裝置，應於水量減至多少時發出警報？",{"webId":378,"number":105,"stem":379,"answer":35,"indexable":20},"fire-109-1-water-chemical-022","室內消防栓之箱面字樣，每字不得小於多少平方公分？",{"webId":381,"number":109,"stem":382,"answer":25,"indexable":20},"fire-109-1-water-chemical-023","下列有關室內消防栓箱之敘述，何者正確？",{"webId":384,"number":113,"stem":385,"answer":35,"indexable":20},"fire-109-1-water-chemical-024","室外消防栓設備之水帶箱設置，箱內應配置口徑 63 毫米及長多少公尺之水帶 2 條？",{"webId":387,"number":117,"stem":388,"answer":19,"indexable":20},"fire-109-1-water-chemical-025","高架倉庫內所設置之撒水頭，其放水量每分鐘應在多少公升以上？",{"webId":390,"number":121,"stem":391,"answer":30,"indexable":20},"fire-109-1-water-chemical-026","密閉式撒水頭之自動撒水設備末端查驗閥規定，下列何者錯誤？",{"webId":393,"number":125,"stem":394,"answer":30,"indexable":20},"fire-109-1-water-chemical-027","中央消防主管機關認定儲存大量可燃物之場所天花板高度超過 6 公尺，或其他場所天花板高度超過 10 公尺者，應採用何種…",{"webId":396,"number":129,"stem":397,"answer":25,"indexable":20},"fire-109-1-water-chemical-028","水霧滅火設備之放射區域有 2 區以上者，其主管管徑不得小於多少毫米？",{"webId":399,"number":133,"stem":400,"answer":25,"indexable":20},"fire-109-1-water-chemical-029","泡沫原液與水混合使用之濃度，下列何種原液之濃度為 1%？",{"webId":402,"number":137,"stem":403,"answer":35,"indexable":20},"fire-109-1-water-chemical-030","泡沫滅火設備計算之水溶液量，應加算充滿配管所需之泡沫水溶液量，且應加算總泡沫水溶液量之百分之多少？",{"webId":405,"number":141,"stem":406,"answer":19,"indexable":20},"fire-109-1-water-chemical-031","使用水成膜泡沫液時，樓地板面積每平方公尺之泡沫頭放射量為每分鐘多少公升以上？",{"webId":408,"number":145,"stem":409,"answer":35,"indexable":20},"fire-109-1-water-chemical-032","二氧化碳滅火設備採用移動放射方式時，每一具噴射瞄子所需滅火藥劑量在多少公斤以上？",{"webId":411,"number":149,"stem":412,"answer":19,"indexable":20},"fire-109-1-water-chemical-033","加壓式乾粉滅火設備應設壓力調整裝置，其可調整壓力至每平方公分多少公斤以下？",{"webId":414,"number":153,"stem":415,"answer":30,"indexable":20},"fire-109-1-water-chemical-034","乾粉滅火設備使用加壓或蓄壓用氣體容器，其所使用之氣體為下列何者？",{"webId":417,"number":157,"stem":418,"answer":35,"indexable":20},"fire-109-1-water-chemical-035","廚房等大量使用火源之處所，多少樓地板面積需有一滅火效能值？",{"webId":420,"number":161,"stem":421,"answer":19,"indexable":20},"fire-109-1-water-chemical-036","任一消防專用蓄水池至建築物各部分之水平距離不得超過多少公尺？",{"webId":423,"number":165,"stem":424,"answer":30,"indexable":20},"fire-109-1-water-chemical-037","連結送水管之配管設置規定，應能承受送水設計壓力 1.5 倍以上之水壓，且能持續多少時間才合格？",{"webId":426,"number":169,"stem":427,"answer":35,"indexable":20},"fire-109-1-water-chemical-038","消防專用蓄水池之設置規定，下列何者正確？",{"webId":429,"number":173,"stem":430,"answer":25,"indexable":20},"fire-109-1-water-chemical-039","公共危險品等場所中，所設置之室外消防栓設備，其緊急電源之供電容量應供其有效動作多久以上？",{"webId":432,"number":13,"stem":433,"answer":35,"indexable":20},"fire-109-1-water-chemical-040","儲槽規定設置補助泡沫消防栓時，下列敘述何者錯誤？",{"count":23,"points":179,"split":435},[117,117],{"name":437,"slug":438,"kicker":439,"count":13,"explained":13,"list":440,"essay":561},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress",[441,444,447,450,453,456,459,462,465,468,471,474,477,480,483,486,489,492,495,498,501,504,507,510,513,516,519,522,525,528,531,534,537,540,543,546,549,552,555,558],{"webId":442,"number":17,"stem":443,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-001","常開式之火警探測器信號回路，加設終端電阻之目的為何？",{"webId":445,"number":23,"stem":446,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-002","使用「加瓦斯試驗器」進行瓦斯漏氣檢知器性能檢查時，若檢測對象的瓦斯對空氣之比重大於 1 者，應使用何種氣體來檢測？",{"webId":448,"number":28,"stem":449,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-003","瓦斯對於空氣之比重大於 1 時，其瓦斯漏氣檢知器應設於距瓦斯燃燒器具水平距離多少公尺以內？",{"webId":451,"number":33,"stem":452,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-004","某火警受信總機設有 15 回路，進行回路能否同時動作測試時，應不要復舊使任意幾回路進行測試？",{"webId":454,"number":38,"stem":455,"answer":30,"indexable":20},"fire-109-1-alarm-evacuation-005","差動式局限型探測器係利用下列何構件，來防止設置場所因正常溫度變化而造成火災誤報？",{"webId":457,"number":42,"stem":458,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-006","差動式局限型探測器進行性能檢查時，使用加熱式試驗器加熱確認動作時間，加熱後到探測器動作應在多少時間以內？",{"webId":460,"number":46,"stem":461,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-007","除火焰式探測器外，一般局限型探測器裝設時，依各類場所消防安全設備設置標準之規定，不得傾斜幾度以上？",{"webId":463,"number":7,"stem":464,"answer":19,"indexable":20},"fire-109-1-alarm-evacuation-008","緊急照明燈在地面之水平面照度，使用低照度測定用光電管照度計測得之值，在地下建築物之地下通道，其地板面應在 X 勒克司…",{"webId":466,"number":53,"stem":467,"answer":19,"indexable":20},"fire-109-1-alarm-evacuation-009","有關避難方向指示燈裝設之敘述，下列何者錯誤？",{"webId":469,"number":57,"stem":470,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-010","緩降機之設置應保有必要操作面積（不含避難器具所占面積），其相關規定下列何者正確？",{"webId":472,"number":61,"stem":473,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-011","避難器具設置數量需衡酌場所之收容人數，依各類場所消防安全設備設置標準規定，百貨商場供飲食或休息用場所之收容人數計算，…",{"webId":475,"number":65,"stem":476,"answer":30,"indexable":20},"fire-109-1-alarm-evacuation-012","有關緊急電源插座之設置規定，下列敘述何者正確？",{"webId":478,"number":69,"stem":479,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-013","無線電通信輔助設備設置之規定，下列敘述何者錯誤？",{"webId":481,"number":73,"stem":482,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-014","某百貨商場之 5 樓樓地板面積為 2,100 平方公尺，依各類場所消防安全設備設置標準規定，該層樓至少應設置幾個防煙…",{"webId":484,"number":77,"stem":485,"answer":19,"indexable":20},"fire-109-1-alarm-evacuation-015","有關排煙設備之設置規定，下列敘述何者錯誤？",{"webId":487,"number":81,"stem":488,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-016","防煙壁為自天花板下垂 X 公分以上之垂壁，但地下建築物之地下通道，防煙壁應自天花板下垂 Y 公分以上，其中 X、Y …",{"webId":490,"number":85,"stem":491,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-017","一一九火災通報裝置之設置規定，下列敘述何者錯誤？",{"webId":493,"number":89,"stem":494,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-018","依住宅用火災警報器認可基準之規定，住宅用火災警報器以警報音發出火災警報，於無響室中距離警報器中心前方 1 公尺處，音…",{"webId":496,"number":93,"stem":497,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-019","具閃滅或音聲引導功能之出口標示燈設置規定，下列敘述何者正確？",{"webId":499,"number":97,"stem":500,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-020","B 級出口標示燈且有顯示避難方向符號者，其有效距離係指步行至該燈多少公尺之距離？",{"webId":502,"number":101,"stem":503,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-021","有關應設置火警自動警報設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":505,"number":105,"stem":506,"answer":30,"indexable":20},"fire-109-1-alarm-evacuation-022","有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X …",{"webId":508,"number":109,"stem":509,"answer":30,"indexable":20},"fire-109-1-alarm-evacuation-023","有關地下建築物總樓地板面積在幾平方公尺以上應設置無線電通信輔助設備，下列何者與各類場所消防安全設備設置標準之規定相同…",{"webId":511,"number":113,"stem":512,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-024","有關標示設備設在避難出口避難指標之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":514,"number":117,"stem":515,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-025","有關火焰式探測器之設置，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":517,"number":121,"stem":518,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-026","有關緊急廣播設備配線之設置，除依屋內線路裝置規則外，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":520,"number":125,"stem":521,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-027","有關緩降機支固器具之裝置，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":523,"number":129,"stem":524,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-028","有關緊急廣播設備啟動裝置與緊急電話設置場所之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規…",{"webId":526,"number":133,"stem":527,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-029","有關瓦斯漏氣火警自動警報設備檢知器外觀檢查選取之檢查數量，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同…",{"webId":529,"number":137,"stem":530,"answer":19,"indexable":20},"fire-109-1-alarm-evacuation-030","有關緊急廣播設備標示燈外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準規定相同？",{"webId":532,"number":141,"stem":533,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-031","有關緊急照明設備性能檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":535,"number":145,"stem":536,"answer":30,"indexable":20},"fire-109-1-alarm-evacuation-032","有關無線電通信輔助設備保護箱標示之外觀檢查的判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":538,"number":149,"stem":539,"answer":19,"indexable":20},"fire-109-1-alarm-evacuation-033","有關緊急電源插座外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":541,"number":153,"stem":542,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-034","有關排煙設備綜合檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":544,"number":157,"stem":545,"answer":35,"indexable":20},"fire-109-1-alarm-evacuation-035","有關避難器具開口部周圍狀況外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":547,"number":161,"stem":548,"answer":30,"indexable":20},"fire-109-1-alarm-evacuation-036","有關定溫式感知線型探測器之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":550,"number":165,"stem":551,"answer":19,"indexable":20},"fire-109-1-alarm-evacuation-037","有關警報系統消防安全設備設置，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":553,"number":169,"stem":554,"answer":25,"indexable":20},"fire-109-1-alarm-evacuation-038","有關應設置緊急照明設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":556,"number":173,"stem":557,"answer":19,"indexable":20},"fire-109-1-alarm-evacuation-039","有關緊急照明設備之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":559,"number":13,"stem":560,"answer":19,"indexable":20},"fire-109-1-alarm-evacuation-040","有關火警自動警報設備受信總機周圍狀況外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"count":23,"points":179,"split":562},[117,117],1785123154574]