[{"data":1,"prerenderedAt":68},["ShallowReactive",2],{"q-fire-106-1-alarm-evacuation-003":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":51,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-警報與避難系統消防安全設備概要-003","fire-106-1-alarm-evacuation-003",106,1,3,"裝設緊急廣播設備之建築物之規定，下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"每一廣播分區不得超過一樓層","各樓層任一點至緊急廣播設備啟動裝置之步行距離應在 50 公尺以下","安全梯或特別安全梯之地下層部分，另設定一廣播分區","廣播區域超過 200 平方公尺時，應設Ｌ級揚聲器","D","第3題一律給分",[],false,"本題考點：緊急廣播設備的廣播分區劃定、啟動裝置步行距離與揚聲器等級的面積門檻，屬找錯誤選項的題型。\n【正解理由】依《各類場所消防安全設備設置標準》第 133 條及第 134 條，揚聲器分 L、M、S 三級，廣播區域超過 100 平方公尺時應設 L 級；超過 50 平方公尺且在 100 平方公尺以下者設 L 級或 M 級；50 平方公尺以下者三級均可。選項所述「超過 200 平方公尺時應設 L 級」與條文的 100 平方公尺不符，敘述錯誤，故選 D。\n【逐項排除】\n(A) 正確。廣播分區以樓層為單位劃定，每一分區不得超過一樓層，確保避難引導廣播能精準指向受災樓層。\n(B) 正確。各樓層任一點至啟動裝置的步行距離應在 50 公尺以下，且設於距樓地板面高度 0.8 公尺以上 1.5 公尺以下。\n(C) 正確。樓梯或斜坡通道另定為一廣播分區，安全梯、特別安全梯之地下層部分並與地上層分別設定分區。\n(D) 錯誤選項，即本題答案。門檻數字為 100 平方公尺，題目寫成 200 平方公尺，把面積級距整整放大一倍。\n【記憶點】揚聲器級距「一百以上用 L、五十到一百 L 或 M、五十以下皆可」。","緊急廣播設備的規範邏輯是「聲音要到得了每個人耳邊，且要說得清楚」。揚聲器分級正是音量與涵蓋面積的對應：L 級音壓 92 分貝以上、M 級 87 分貝以上未達 92、S 級 84 分貝以上未達 87，面積愈大需要愈高音壓才能克服距離衰減與背景噪音，故條文以 100 與 50 平方公尺兩個級距切分。另有補充規定，從各廣播區域內任一點至揚聲器的水平距離應在 10 公尺以下，避免大空間只靠角落一支喇叭充數；居室樓地板面積在 6 平方公尺以下、或走廊、通道面積在 6 平方公尺以下且距其他區域揚聲器 8 公尺以內者得免設，這組「6 與 8」也是高頻考點。\n廣播分區的劃定同樣有明確原則：每一分區不得超過一樓層，是為了配合火災時的分區廣播順序（起火層與其直上層優先）；樓梯、斜坡通道因垂直貫通全棟，另設為一分區，且安全梯與特別安全梯的地下層部分與地上層分開，避免地上層廣播誤導地下層人員往上湧入煙流路徑。\n啟動裝置的 50 公尺步行距離與 0.8 至 1.5 公尺設置高度，是與火警自動警報設備手動報警機共通的設計思維——任何人在任何位置都能在短時間內走到並操作。緊急廣播設備與火警自動警報設備連動時，受信總機動作後應自動啟動廣播，兩系統的分區劃定可以不同，這是概念易混處：火警的警報分區以偵測範圍劃定、廣播分區以播音範圍劃定，題目問哪一個要看清楚主詞。\n延伸考點包括擴音機及操作裝置的設置場所（經常有人之處所）、緊急電源容量、以及與一般廣播共用時的音源切換要求。",true,[28,32,36,39,43,47],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-alarm-evacuation-002","對於消防安全設備緊急供電系統之配線之規定，下列何者正確？",2,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-alarm-evacuation-004","依各類場所消防安全設備檢修及申報作業基準規定，1 種光電式局限型偵煙探測器於使用加煙試驗器確認動作之時間，加煙後至動作應在多少時間內方為合格？",4,{"webId":37,"stem":38,"number":12,"year":11,"session":12},"fire-106-1-alarm-evacuation-001","某一 KTV 視聽歌唱場所設於大樓地下層，依規定樓地板面積如合計超過多少，應設置瓦斯漏氣火警自動警報設備？",{"webId":40,"stem":41,"number":42,"year":11,"session":12},"fire-106-1-alarm-evacuation-005","依各類場所消防安全設備設置標準規定，下列何種場所如設置高感度密閉式撒水頭自動撒水設備，得免設火警自動警報設備？",5,{"webId":44,"stem":45,"number":35,"year":46,"session":12},"fire-114-1-alarm-evacuation-004","某電影院放映場所火警自動警報設備所使用之蓄積型偵煙探測器有 10 秒之蓄積時間，其所使用之中繼器有 10 秒之蓄積時間，則其受信總機之蓄積時間，最多可為多少秒？",114,{"webId":48,"stem":49,"number":50,"year":11,"session":12},"fire-106-1-alarm-evacuation-006","樓梯、斜坡通道、昇降機之昇降路及管道間等場所，其頂層相差在二層以下、水平距離多少範圍內，視為一火警分區？",6,[52,56,60,64],{"webId":53,"year":54,"stem":55,"number":13},"fire-110-1-alarm-evacuation-003",110,"建築物有某一樓層樓地板面積 900 平方公尺且設置之避難方向指示燈均為 C 級，該樓層最有可能為下列何種用途？",{"webId":57,"year":58,"stem":59,"number":13},"fire-109-1-alarm-evacuation-003",109,"瓦斯對於空氣之比重大於 1 時，其瓦斯漏氣檢知器應設於距瓦斯燃燒器具水平距離多少公尺以內？",{"webId":61,"year":62,"stem":63,"number":13},"fire-108-1-alarm-evacuation-003",108,"用途為補習班，居室樓地板面積 300 平方公尺，採用有效通風方式檢討，其排煙口設於天花板下方 80 公分內，試問有效通風面積最少須要多少平方公尺以上方可符合規定？",{"webId":65,"year":66,"stem":67,"number":13},"fire-107-1-alarm-evacuation-003",107,"下列何者非屬定溫式探測器可裝設場所？",1785123172618]