[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-106-1-alarm-evacuation-005":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-警報與避難系統消防安全設備概要-005","fire-106-1-alarm-evacuation-005",106,1,5,"依各類場所消防安全設備設置標準規定，下列何種場所如設置高感度密閉式撒水頭自動撒水設備，得免設火警自動警報設備？",{"A":16,"B":17,"C":18,"D":19},"高層建築物","地下建築物","戲院","乙類場所","D",null,[],false,"本題考點：設置自動撒水設備（採高感度密閉式撒水頭）後，得免設火警自動警報設備的場所範圍與除外規定。\n【正解理由】依《各類場所消防安全設備設置標準》第 20 條，應設火警自動警報設備之場所，設有自動撒水設備且採用密閉式撒水頭（含高感度型）並具有火災感知連動報警功能，於該有效範圍內得免設火警自動警報設備；但甲類場所、地下建築物、高層建築物或應設偵煙式探測器之場所不在此限。四個選項中僅乙類場所未被排除，故選 D。\n【逐項排除】\n(A) 高層建築物：屬條文明列的除外對象。垂直延燒與避難時間長，必須維持獨立的火警自動警報系統。\n(B) 地下建築物：同屬明列除外。無外氣開口、煙層下降快，撒水動作的連動報警不足以取代早期偵測。\n(C) 戲院：屬甲類場所，人員密集且黑暗環境不利自行發覺火災，為除外對象。\n(D) 乙類場所：未列於除外範圍，於撒水設備有效範圍內得免設火警自動警報設備，符合題意。\n【記憶點】撒水可免火警，但「甲類、地下、高層」三者永遠不放行。","這條免設規定的理論基礎是「功能替代」：密閉式撒水頭本身就是一個熱感知元件，動作後二次側洩壓使流水檢知裝置作動，經壓力開關送出訊號至受信總機發出警報，等於同時完成偵測、報警與滅火三件事。既然功能重疊，法規允許在撒水設備的有效範圍內免設火警自動警報設備，避免重複投資。高感度型撒水頭（標示溫度較低、反應時間指數 RTI 較小）動作更快，替代的正當性更強，故條文特別點名。\n但替代有其極限，這正是除外規定的由來。第一，撒水頭是感熱元件，必須等熱氣流累積到標示溫度才動作，對陰燃階段的煙毫無反應；地下建築物與應設偵煙式探測器的場所需要的是煙的早期偵測，感熱替代等於把警報延到火勢成長期。第二，甲類場所人員密集、對環境不熟悉，戲院、KTV 等更常處於昏暗或高噪音狀態，警報時間每延後一分鐘，避難成功率就明顯下降。第三，高層建築物避難距離長、須採分區警報與逐層引導，撒水連動的單一訊號難以支撐完整的避難廣播與引導程序。\n易混淆對照：免設火警自動警報設備與免設探測器是兩件事——前者是整套系統的免設，後者是條文另定於特定處所（如主要構造為防火構造之廁所、浴室、洗手間等）得免設探測器；另外自動撒水設備本身也有免設條款（如設有水霧、泡沫、二氧化碳等滅火設備之有效範圍內），三組免設規定各有母法條文，切勿互相套用。\n延伸考法常見於改問「下列何者不得免設」，把甲類場所換成具體業種（電影院、舞廳、醫院、飯店餐廳）測驗場所分類的熟悉度，因此背條文之外還要能把場所名稱對回甲、乙、丙、丁類。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-alarm-evacuation-004","依各類場所消防安全設備檢修及申報作業基準規定，1 種光電式局限型偵煙探測器於使用加煙試驗器確認動作之時間，加煙後至動作應在多少時間內方為合格？",4,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-alarm-evacuation-006","樓梯、斜坡通道、昇降機之昇降路及管道間等場所，其頂層相差在二層以下、水平距離多少範圍內，視為一火警分區？",6,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-alarm-evacuation-003","裝設緊急廣播設備之建築物之規定，下列何者錯誤？",3,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-alarm-evacuation-007","如設置救助袋做為避難器具，下列敘述何者錯誤？",7,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-alarm-evacuation-002","對於消防安全設備緊急供電系統之配線之規定，下列何者正確？",2,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-alarm-evacuation-008","天花板設排氣口或回風口時，偵煙式探測器應裝置於排氣口或回風口周圍多少距離範圍內？",8,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-005",110,"避難方向指示燈之認可作業中，其引導燈具不包括下列何種附加功能？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-005",109,"差動式局限型探測器係利用下列何構件，來防止設置場所因正常溫度變化而造成火災誤報？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-alarm-evacuation-005",108,"瓦斯漏氣火警自動警報設備進行性能檢查，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-alarm-evacuation-005",107,"有一地下三層地上十層之建築物，總樓地板面積 5000 平方公尺，若起火樓層位於三樓時，下列那一樓層火警自動警報設備須鳴動？",1785123172631]