[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-106-1-alarm-evacuation-021":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-警報與避難系統消防安全設備概要-021","fire-106-1-alarm-evacuation-021",106,1,21,"下列消防安全設備緊急供電系統之配線，何者需施予耐燃保護？",{"A":16,"B":17,"C":18,"D":19},"室內消防栓之控制盤至啟動裝置","火警自動警報設備之受信總機至火警警鈴","緊急廣播設備之擴音機至揚聲器","二氧化碳滅火設備排放裝置至緊急電源","D",null,[],false,"本題考點：緊急供電系統配線之保護等級區分，重點在辨別哪些線路須「耐燃保護」、哪些僅需「耐熱保護」。\n【正解理由】依《各類場所消防安全設備設置標準》第 235 條，緊急供電系統之配線，於電源回路（自緊急電源至各設備控制盤之間）及滅火設備之緊急電源回路等關鍵區段應施予耐燃保護，其餘操作回路、表示燈回路、警報回路及標示燈回路則施予耐熱保護即可。判別主軸是「斷了就整套設備失去動力」的供電幹線屬耐燃，「斷了只影響局部顯示或鳴動」的支線屬耐熱。二氧化碳滅火設備之排放裝置至緊急電源之間屬供電幹線，且該設備須在火勢中持續作動完成藥劑放射，故選 D。\n【逐項排除】\n(A) 室內消防栓之控制盤至啟動裝置：此段屬啟動操作回路，非電源幹線，依同條規定施予耐熱保護即可。\n(B) 火警自動警報設備之受信總機至火警警鈴：屬警報回路，警鈴為末端發音裝置，規定為耐熱保護。\n(C) 緊急廣播設備之擴音機至揚聲器：屬音響傳輸之操作回路，亦僅需耐熱保護。\n(D) 二氧化碳滅火設備排放裝置至緊急電源：屬緊急電源至滅火設備之電源回路，須耐燃保護，為正解。\n【記憶點】電源幹線走耐燃、操作警報走耐熱——問到「到緊急電源」那一段，答案幾乎都是耐燃。","《各類場所消防安全設備設置標準》第 235 條同時定義了兩種保護工法。耐燃保護的作法有三：一是使用電線並置於金屬導線管槽內，並埋設於防火構造物之混凝土內，混凝土保護厚度須達二十公厘以上；二是使用電纜並置於金屬導線管槽內，配置於具一小時以上防火時效之管道間；三是使用MI電纜或耐燃電纜等經中央主管機關認可具耐燃性能之配線。耐熱保護則放寬為金屬導線管槽配線，或使用耐熱電線電纜等具耐熱性能之配線。兩者的差別在於火焰直接炙燒時的存活時間——耐燃要求在火中仍能維持迴路導通，耐熱僅要求在高溫環境中不劣化短路。\n這種分級的立法理由是成本與功能的權衡。滅火設備一旦啟動，其幫浦、電動閥、藥劑放射控制往往需在火場邊緣持續運轉數分鐘至數十分鐘，供電中斷等於滅火失敗，故供電幹線必須耐燃；反之，火警警鈴或揚聲器多在火災初期即完成告警任務，即使後續線路被燒斷，避難行為已經啟動，故容許耐熱等級。二氧化碳滅火設備更具特殊性：其為全區放射之窒息型滅火，放射前須先確認人員撤離、關閉開口部、啟動音響警報並經延遲時間，整個程序高度依賴電力，因此與緊急電源相連的區段被明確列入耐燃保護。\n易混淆對照可整理成兩欄：耐燃側包含緊急電源至各消防安全設備控制盤之電源回路、滅火設備電源回路、緊急電源專用受電設備至配電盤之線路；耐熱側包含火警自動警報設備之探測器回路與地區音響回路、緊急廣播之揚聲器回路、標示燈與表示燈回路、消防栓啟動表示燈回路。答題時只要問自己「這段線斷了，設備還能動作嗎」，能導出正確歸類。\n相關考點連結上，同章尚有緊急電源本身的規定：緊急電源得使用發電機設備、蓄電池設備或具有相同效果之設備，容量須能使設備有效動作三十分鐘以上（部分設備另有特別規定）；緊急電源專用受電設備與配電盤、分電盤之防護規定，以及緊急電源插座、無線電通信輔助設備等，常與配線保護併題出現。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-alarm-evacuation-020","差動式探測器之動作原理為感應火場中何種參數？",20,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-alarm-evacuation-022","依出口標示燈及避難方向指示燈認可基準規定，燈具附有起動器者，應在多少時間內點燈？",22,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-alarm-evacuation-019","一居室設置於地上層，該樓層亦非為無開口樓層，自內部任一點易於識別主要出入口，主要出入口之步行距離在多少以下者，得免設避難方向指示燈？",19,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-alarm-evacuation-023","一大樓內部某樓層設有不得供避難、通行及搬運以外用途之防火構造架空走廊一座，該樓層可依法減設多少具避難器具？",23,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-alarm-evacuation-018","依各類場所消防安全設備檢修及申報作業基準規定，火焰探測器以動作試驗器確認探測器之動作應在多少時間內方為合格？",18,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-alarm-evacuation-024","依各類場所消防安全設備設置標準規定，特別安全梯或緊急昇降機間排煙室之排煙設備設置排煙、進風風管時，下列何者有誤？",24,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-021",110,"下列有關免設火警探測器之場所，何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-021",109,"有關應設置火警自動警報設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-alarm-evacuation-021",108,"依各類場所消防安全設備設置標準規定，下列危險物品場所何者不須設置火警自動警報設備？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-alarm-evacuation-021",107,"依各類場所消防安全設備設置標準規定，緊急照明設備除內置蓄電池外，應連接緊急電源，其蓄電池容量應能使其持續動作 a 分鐘以上。但採蓄電池設備與緊急發電機併設方式時，其容量應能使其持續動作分別為 b 分鐘及 c 分鐘以上，請問下列何者正確？",1785123172793]