[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-fire-law-006":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-消防法規概要-006","fire-106-1-fire-law-006",106,1,6,"依據各類場所消防安全設備設置標準規定，集會堂使用之舞臺在設置自動撒水設備時，應選擇下列何者？",{"A":16,"B":17,"C":18,"D":19},"密閉濕式","密閉乾式","開放式","預動式","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》中自動撒水設備型式之選擇規定,特別是舞臺應採開放式之特別規定。\n【正解理由】依《各類場所消防安全設備設置標準》關於自動撒水設備型式選擇之規定,電影攝影場、電視播送室、舞臺及道具室等場所,應採用開放式自動撒水設備。理由在於舞臺具有大量布幕、道具、木作與可燃裝飾,且上方挑高、氣流複雜,火勢延燒極快;開放式撒水頭無感熱元件,由感知裝置動作後一齊放水,能在最短時間內以整區放水壓制,不必等每一顆撒水頭逐一受熱動作,故選 C。\n【逐項排除】\n(A) 錯誤。密閉濕式為一般場所的原則型式,撒水頭須逐顆受熱破裂才放水,對舞臺的快速延燒反應過慢。\n(B) 錯誤。密閉乾式主要用於配管有凍結之虞的寒冷或無暖氣場所,放水前尚須排氣,延遲更久,並非舞臺的指定型式。\n(C) 正確。舞臺與電影攝影場、電視播送室同列,規定應採開放式,以一齊放水涵蓋整個防護區域。\n(D) 錯誤。預動式用於避免誤動作造成水損的電子機房等場所,須探測與撒水頭雙重動作才放水,反應更保守,與舞臺需求相反。\n【記憶點】「舞臺、攝影棚、播送室——一律開放式,一齊放水搶時間」。","自動撒水設備的型式選擇規定,本質上是把「反應速度」與「誤放水風險」兩件事做權衡後的分類表,四種型式的差異可用兩個變數理解:配管內是水還是空氣、撒水頭是密閉還是開放。密閉濕式配管常時充水、撒水頭密閉,受熱後感熱元件動作即放水,反應最快也最單純,是絕大多數場所的原則型式。密閉乾式配管內充壓縮空氣,撒水頭動作後空氣先排出、水才推進,代價是延遲,好處是配管不會凍結,因此用在有凍結之虞的場所。預動式在密閉撒水頭之外再串一套探測器,必須探測器與撒水頭都動作才放水,設計目的是防止配管漏水或撒水頭遭外力破壞時造成貴重設備水損。開放式撒水頭沒有感熱元件,噴口常時開放,由探測系統或手動啟動一齊開放閥後,整個防護區域同時放水。\n舞臺被指定為開放式,背後有很具體的火災學理由。舞臺區通常挑高數層,上方設有懸吊布幕、燈具與道具,可燃物垂直分布且比表面積大,一旦起火會沿布幕垂直延燒,火羽流迅速把熱煙送到頂棚。密閉式撒水頭裝在頂棚,等它受熱動作時火勢已經沿垂直面擴大;而且撒水頭逐顆動作會分散水量,對已經竄升的火勢壓制不足。開放式一齊放水則能同時形成整片水幕,兼具冷卻與阻隔延燒之效。同樣的邏輯也用在電影攝影場與電視播送室——大量布景、電纜與燈具高熱源,火載量高且人員密集。\n數值上可一併記:自動撒水設備各型式的放水壓力原則在每平方公分 1 公斤以上、每分鐘放水量 80 公升以上;開放式與一齊開放閥、探測系統的連動,則與泡沫滅火設備的一齊開放閥概念相通,兩者常被交叉命題。易混淆點在於「開放式」與「水霧」都會整區放水,但開放式屬自動撒水設備、以冷卻為主;水霧則以微細水滴的冷卻、窒息與乳化作用兼具,適用油類與電氣火災,兩者的適用場所與放水量規定並不相同,不可互換作答。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-fire-law-005","依各類場所消防安全設備設置標準規定，下列何種場所應設置連結送水管？",5,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-fire-law-007","依據各類場所消防安全設備設置標準規定，公共危險物品製造場所符合下列何者要件，則屬顯著滅火困難場所？",7,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-fire-law-004","依各類場所消防安全設備設置標準規定，幼兒園按用途分類係屬於何種場所？",4,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-fire-law-008","依據各類場所消防安全設備設置標準規定，對瓦斯漏氣檢知器設置，下列敘述何者正確？",8,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-fire-law-003","下列有關公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之相關用語定義，何者正確？",3,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-fire-law-009","依據各類場所消防安全設備設置標準規定，公共危險物品等場所之滅火設備分類，下列敘述何者正確？",9,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-006",111,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，六類公共危險物品之儲存及處理，應遵守之規定，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-fire-law-006",110,"消防設備師及消防設備士，自取得證書日起應定期接受講習訓練，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-fire-law-006",109,"依消防設備師及消防設備士管理辦法之規定，如通過消防設備士考試，取得證書日起每 3 年應接受講習 1 次或取得累計積分達 160 分以上之訓練證明文件，其中參加中央主管機關舉辦或認可之講習會 2 小時可得到多少積分？",{"webId":66,"year":67,"stem":68,"number":13},"fire-108-1-fire-law-006",108,"有關消防設備師及消防設備士業務及責任，下列何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-107-1-fire-law-006",107,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，容器串接使用場所，係指使用液化石油氣作為燃氣來源，其串接使用量達多少公斤以上之場所？",1785123159782]