[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-fire-law-020":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-消防法規概要-020","fire-106-1-fire-law-020",106,1,20,"依據各類場所消防安全設備設置標準規定，設置於可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽之滅火器，其滅火效能值規定，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"對普通火災具有 8 個以上之滅火效能值，對油類火災具有 16 個以上之滅火效能值","對普通火災具有 6 個以上之滅火效能值，對油類火災具有 12 個以上之滅火效能值","對普通火災具有 4 個以上之滅火效能值，對油類火災具有 10 個以上之滅火效能值","對普通火災具有 3 個以上之滅火效能值，對油類火災具有 5 個以上之滅火效能值","C",null,[],false,"本題考點：可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽所設滅火器的滅火效能值標準。\n【正解理由】依《各類場所消防安全設備設置標準》關於滅火器設置之規定，設置於可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽之滅火器，應對普通火災具有 4 個以上之滅火效能值，對油類火災具有 10 個以上之滅火效能值，並對電氣火災具有適應性。此一組合反映該類場所以氣體與油類火災為主要風險，故對油類火災的效能值要求明顯高於普通火災，故選 C。\n【逐項排除】\n(A) 普通 8、油類 16：數值明顯高於法定要求，屬把兩個數字同倍放大的誘答。\n(B) 普通 6、油類 12：維持了「油類為普通兩倍」的錯誤比例印象，但與條文所定數值不符。\n(C) 普通 4、油類 10：與條文一致，且正確呈現油類要求高於普通火災的不對稱關係，正確。\n(D) 普通 3、油類 5：數值偏低，且油類與普通僅差 2，低估了氣體與油類場所的滅火需求。\n四個選項的差異在於兩個效能值的絕對數與相對比例，只有 C 同時符合條文所定的數值，其餘三者不是整體偏高、偏低，就是把兩者比例記成單純的二倍關係。\n【記憶點】高壓氣體與加氣站的滅火器記「普四油十」，油類要求遠高於普通火災。","滅火效能值是我國滅火器規範的核心量化指標，來自標準模型火試驗：以 A 類(普通火災)木垛模型與 B 類(油類火災)油盤模型進行實際滅火，能撲滅幾個單位模型火，就標示為幾個效能值，標示方式即滅火器銘板上的「A－B－C」。因此效能值不是藥劑重量，而是實測滅火能力，這點是概念題的常見考點：兩支同重量的滅火器，藥劑種類不同，效能值可能相差甚多。\n\n為何本類場所要求「油類 10、普通 4」的不對稱組合？可燃性高壓氣體場所與加氣站的火災情境，主流是液化石油氣洩漏後的噴射火焰、油氣混合物的流動火，以及泵浦、管線的油品火災，火勢發展快、輻射熱強，屬 B 類為主；A 類可燃物(包裝材、辦公雜物)相對次要。法規因此把資源壓在 B 類能力上，同時要求對電氣火災具適應性，因為場區內有加氣機、控制盤與電動閥等帶電設備。這種「依場所火災型態決定效能值配比」的思路，也是判讀其他場所滅火器條文的通則。\n\n數值對照記憶：一般建築物滅火器以「每一滅火器之防護距離在 20 公尺以下」與樓地板面積分擔為配置原則；而本類高風險場所改以效能值門檻直接管制。兩套邏輯併存，命題時常混合詢問「應設幾支」與「效能值多少」，作答前先辨明問的是配置密度還是能力門檻。\n\n易混淆概念對照：滅火器適用火災分類為 A 類普通火災、B 類油類火災、C 類電氣火災、D 類金屬火災。C 類不標效能值而只論「適應性」，因為電氣火災的關鍵是藥劑不導電，無法用模型火量化；D 類則需專用乾粉。另需區分滅火器與簡易自動滅火設備、以及公共危險物品場所另以「第一種至第五種滅火設備」分類的體系，後者屬公共危險物品辦法而非設置標準的一般規定。\n\n延伸考點連結：滅火器的設置高度(上端距樓地板面 1.5 公尺以下)、標示、每年檢查與加壓式乾粉滅火器的耐壓試驗規定，常與本題同章併考。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-fire-law-019","依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，壓力儲槽應設置安全裝置；非壓力儲槽應設置通氣管。上述壓力儲槽係指為何？",19,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-fire-law-021","下列有關消防法施行細則第 14 條防火管理人規定之敘述，何者錯誤？",21,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-fire-law-018","依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，可燃性高壓氣體儲存場所設有防爆牆或同等以上防護性能者，倘其儲存面積未達多少平方公尺時，其與第一類保護物及第二類保護物安全距離得縮減為零？",18,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-fire-law-022","下列有關消防法相關規定之敘述，何者錯誤？",22,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-fire-law-017","依據消防法規定，為因應災害搶救時消防之需要，有關下列消防栓設置、費用、保養及維護，何者正確？",17,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-fire-law-023","下列有關消防設備師及消防設備士管理辦法規定之敘述，何者錯誤？",23,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-020",111,"依消防法規定，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-fire-law-020",110,"依法應裝設火警自動警報設備之建築物，其裝設受信總機及探測器等相關規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-fire-law-020",109,"依可燃性高壓氣體儲存場所防護牆設置基準之規定，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-108-1-fire-law-020",108,"依據消防設備師及消防設備士管理辦法規定，消防設備師及消防設備士，自取得證書日起每 3 年應接受講習一次或取得累計積分達多少分以上之訓練證明文件？",{"webId":70,"year":71,"stem":72,"number":13},"fire-107-1-fire-law-020",107,"依各類場所消防安全設備設置標準之規定，特別安全梯或緊急昇降機間排煙室之排煙設備，其排煙機、進風機之排煙量、進風量應在每秒 a 立方公尺（兼用時，每秒 b 立方公尺）以上，且可隨排煙口、進風口開啟而自動啟動。a、b 各為何值？",1785123159941]