[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-106-1-fire-law-038":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-消防法規概要-038","fire-106-1-fire-law-038",106,1,38,"下列有關建築技術規則建築設計施工編建築技術用語規定之敘述，何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"閣樓：在屋頂內之樓層，樓地板面積在該建築物建築面積四分之一以上時，視為另一樓層","總樓地板面積：建築物各層包括地下層、屋頂突出物及夾層等樓地板面積之總和","建蔽率：建築面積占基地面積之比率","集合住宅：具有共同基地及共同空間或設備。並有 3 個住宅單位以上之建築物","A",null,[],false,"本題考點：《建築技術規則》建築設計施工編建築技術用語之定義,重點在閣樓視為另一樓層的面積比例。\n【正解理由】依《建築技術規則》建築設計施工編第 1 條用語定義,閣樓係指在屋頂內之樓層,其樓地板面積在該建築物建築面積三分之一以上時,視為另一樓層;題目選項寫成四分之一以上,比例與條文不符。此一比例攸關樓層數認定,進而影響消防安全設備應設置與否之判斷,故選 A。\n【逐項排除】\n(A) 敘述錯誤,為本題應選項。閣樓視為另一樓層之門檻為建築面積三分之一以上,並非四分之一以上。\n(B) 敘述正確。總樓地板面積係建築物各層,包括地下層、屋頂突出物及夾層等樓地板面積之總和,此定義是消防設備設置門檻計算的基礎。\n(C) 敘述正確。建蔽率為建築面積占基地面積之比率,與容積率(總樓地板面積占基地面積之比率)相對應。\n(D) 敘述正確。集合住宅指具有共同基地及共同空間或設備,並有三個住宅單位以上之建築物,三個單位為其數量門檻。\n【記憶點】閣樓「三分之一」才算一層;建蔽看水平投影、容積看樓地板總和。","建築技術用語之所以在消防設備士考科中反覆出現,是因為《各類場所消防安全設備設置標準》的設置門檻,幾乎全部建立在建築用語之上:樓層數決定是否應設某項設備、總樓地板面積決定水源容量與分區鳴動適用、樓地板面積決定探測器數量與防護範圍。若把建築用語定義記錯,後續整條計算鏈都會歪掉,因此命題者偏好從定義端下手。\n\n閣樓的三分之一門檻,設計理由在於區分「屋頂內的零星使用空間」與「實質可供使用的完整樓層」。當屋頂內樓層的樓地板面積達到建築面積三分之一,其可容納人員與存放物品的規模已與一般樓層相當,自應計入樓層數,連帶影響避難層數認定與消防設備設置。相對地,屋頂突出物則另有其認定規則,面積與高度合於一定條件者不計入樓層數,兩者常被混為一談。\n\n數值對照可整理成一組:閣樓三分之一;集合住宅三個住宅單位以上;建蔽率為建築面積除以基地面積;容積率為總樓地板面積除以基地面積。其中建築面積指建築物外牆中心線水平投影面積,是「地面上的影子」;總樓地板面積是「各層加總」,包含地下層、屋頂突出物與夾層。把「投影」與「加總」兩個意象分開,便不易在建蔽率與容積率之間混淆。\n\n易混淆概念另有二:其一,夾層與閣樓不同,夾層是在樓地板與天花板之間附加之樓層,其面積達一定比例時亦有特別規定;其二,樓層數與層數的用語,在不同法規中的計算方式可能因是否計入地下層而異,答題時應回到題目所引法規本身的定義。\n\n相關考點延伸:建築用語常與防火構造、防火時效、防護區劃、直通樓梯及安全梯之設置一併命題,也常反向以「何者定義錯誤」形式出現。準備時建議把《建築技術規則》建築設計施工編第 1 條的用語逐條抄成卡片,特別標注所有出現分數與整數的門檻值,因為那正是選項被竄改的位置。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-fire-law-037","下列有關消防幫浦之性能規定之敘述，何者正確？",37,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-fire-law-039","依據建築技術規則建築設計施工編規定，下列用語定義何者正確？",39,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-fire-law-036","下列有關各類場所消防安全設備檢修及申報作業基準行政函釋之敘述，何者錯誤？",36,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-fire-law-040","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，下列有關「六類物品製造場所，其外牆或相當於該外牆之設施外側，與廠區外鄰近場所之安全距離」之敘述，何者錯誤？",40,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-fire-law-035","下列有關建築物消防安全設備竣工查驗程序規定之敘述，何者錯誤？",35,{"webId":49,"stem":50,"number":12,"year":51,"session":12},"fire-107-1-fire-law-001","依消防法之規定，液化石油氣零售業者應備置資料，定期向轄區消防機關申報，並保存多久，以備查核？",107,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-038",111,"有關加壓送水裝置之電動機，其種類、構造及機能等之敘述，何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-fire-law-038",110,"依建築技術規則建築設計施工編規定，有關防火門構造等相關規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-fire-law-038",109,"依建築技術規則建築設計施工編之定義，經主管機關認可後，下列何者屬「防火設備」？",{"webId":66,"year":67,"stem":68,"number":13},"fire-108-1-fire-law-038",108,"依據消防設備師及消防設備士管理辦法規定，有關技術研討活動或訓練，其辦理機關（構）、團體應於舉辦 X 個月前，檢附文件向中央主管機關申請認可，中央主管機關並於舉辦 Y 個月前准駁之，另於技術研討活動或訓練結束後 Z 個月內應檢附參加之消防設備師及消防設備士簽到表及參加時數清冊，向中央主管機關申請訓練積分審查及登記。請問下列何者正確？",{"webId":70,"year":51,"stem":71,"number":13},"fire-107-1-fire-law-038","依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，呼水裝置應有多少公升以上之有效儲存量？",1785123160121]