[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-106-1-water-chemical-003":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":51,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-水與化學系統消防安全設備概要-003","fire-106-1-water-chemical-003",106,1,3,"有關滅火器設置間距之規定，下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"設有滅火器之樓層或場所，自樓面居室任一點或防護對象任一點至滅火器之步行距離不得超過 20 公尺","電影片映演場所放映室及電氣設備使用之處所，滅火器至防護對象任一點之步行距離應在 15 公尺以下","公共危險物品等場所中一般滅火困難之場所，設置大型滅火器時距防護對象任一點之步行距離，應在 30 公尺以下","可燃性高壓氣體儲存場所，任一點至滅火器之步行距離應在 15 公尺以下","B",null,[],false,"本題考點：滅火器設置的步行距離規定,考的是一般樓層 20 公尺、公共危險物品場所與可燃性高壓氣體場所的特別規定,以及放映室與電氣設備處所究竟適用何種標準,題目問的是「錯誤」者。\n【正解理由】依《各類場所消防安全設備設置標準》第 31 條,設有滅火器之樓層,自樓面居室任一點至滅火器之步行距離在 20 公尺以下;至於電影片映演場所放映室及電氣設備使用之處所,條文所定的是「每 100 平方公尺(含未滿)另設一滅火器」的數量加設規定,並非另訂 15 公尺的步行距離門檻,該敘述與條文不符,故選 B。\n【逐項排除】\n(A) 一般設有滅火器之樓層或場所,自樓面居室任一點或防護對象任一點至滅火器之步行距離不得超過 20 公尺,與條文相符,敘述正確。\n(B) 放映室及電氣設備使用之處所的規定為依面積加設滅火器數量,而非步行距離 15 公尺以下,屬張冠李戴,是本題的錯誤敘述,為正確答案。\n(C) 公共危險物品等場所中滅火困難場所設置大型滅火器時,至防護對象任一點之步行距離應在 30 公尺以下,與《公共危險物品設置標準》相符,敘述正確。\n(D) 可燃性高壓氣體儲存場所,任一點至滅火器之步行距離應在 15 公尺以下,與規定相符,敘述正確。\n【記憶點】一般 20 公尺、大型滅火器 30 公尺、可燃性高壓氣體 15 公尺;放映室是加設數量,不是縮短距離。","步行距離的規範邏輯是「人能在初期火災的黃金時間內取得器材並折返」。以一般人步行速度約 1 公尺\u002F秒估算,20 公尺往返約需 40 秒,加上取用與趨近火點,仍落在火災成長初期,這是 20 公尺這個數字的由來;而大型滅火器藥劑量大、多設於室外或推車式,放寬到 30 公尺;可燃性高壓氣體場所因火勢發展極快、爆炸風險高,反而縮短為 15 公尺。三個數字建議連同適用對象一起記,考題最愛互換。\n\n須特別分清楚的是「步行距離」與「水平距離」:步行距離指沿實際可通行路徑行走的長度,須繞過隔間與障礙;水平距離則是平面上的直線距離,常用於撒水頭、探測器與室內消防栓的配置判準(如室內消防栓瞄子放水的防護半徑)。同一份考卷若一題問步行、一題問水平,判準完全不同,誤讀即失分。\n\n放映室與電氣設備處所之所以採「加設數量」而非「縮短距離」,是因為這類空間本身面積不大但火載量與電氣風險集中,規範選擇以密度(每 100 平方公尺加設一具)確保器材就在手邊,與鍋爐房、廚房等使用火源處所的加設邏輯一致。\n\n延伸考點:滅火器除步行距離外,尚有設置高度、標示、以及依火災類別(A 類普通火災、B 類油類火災、C 類電氣火災、D 類金屬火災)選用適當藥劑的要求;電氣設備處所須選用不導電藥劑,金屬火災不得使用水系滅火器。檢修方面,滅火器應定期實施外觀檢查與性能檢查,並依《消防安全設備檢修及申報作業基準》申報,常與本條併題出現;公共危險物品場所另依滅火困難程度分為極困難、一般困難與其他場所三級,對應不同的滅火設備配置要求,是本科的另一組高頻對照表。",true,[28,32,36,39,43,47],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-water-chemical-002","依各類場所消防安全設備設置標準，下列何種場所不需設置滅火器？",2,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-water-chemical-004","依滅火器認可基準，大型滅火器充填乾粉時，滅火藥劑量需在多少公斤以上？",4,{"webId":37,"stem":38,"number":12,"year":11,"session":12},"fire-106-1-water-chemical-001","依 NFPA 2001 之規定，潔淨式氣體滅火系統於一般場所之藥劑放射時間（達設計濃度 95%之時間），下列何者錯誤？",{"webId":40,"stem":41,"number":42,"year":11,"session":12},"fire-106-1-water-chemical-005","某一鍋爐房之長寬高分別為 8 m、5 m 及 4 m，若設置全區放射 CO2 滅火設備，其所有開口皆可在放射前自動關閉，試問所需 CO2 藥劑量至少應為多少公斤？",5,{"webId":44,"stem":45,"number":35,"year":46,"session":12},"fire-114-1-water-chemical-004","依各類場所消防安全設備設置標準規定，鹵化烴滅火設備，蓄壓式儲存容器儲存 HFC-227ea、 FK-5-1-12 之儲存壓力，應以氮氣加壓至 X MPa 以上。加壓式儲存容器，應設置可調整壓力至 Y MPa 之壓力調整裝置。則 X+Y 為多少？",114,{"webId":48,"stem":49,"number":50,"year":11,"session":12},"fire-106-1-water-chemical-006","全區放射二氧化碳滅火設備進行綜合檢查時，如為低壓式儲存系統，在放射試驗時需放射多少藥劑量？",6,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-111-1-water-chemical-003",111,"某公共危險物品場所設置室外消防栓設備，在裝置全部消防栓數量 5 支時，其所需之水源容量至少應為多少立方公尺以上？",{"webId":57,"year":58,"stem":59,"number":13},"fire-110-1-water-chemical-003",110,"公共危險物品等場所消防設計及消防安全設備，顯著滅火困難場所之室外儲槽場所，儲存硫磺，應設置何種滅火設備？",{"webId":61,"year":62,"stem":63,"number":13},"fire-109-1-water-chemical-003",109,"某建築物之室內、外消防栓、自動撒水及水霧滅火等設備配管採連通設計並共用消防幫浦，其共用消防幫浦之出水量和全揚程之要求標準為何？",{"webId":65,"year":66,"stem":67,"number":13},"fire-108-1-water-chemical-003",108,"中央主管機關認定儲存大量可燃物之場所天花板高度超過 X 公尺，或其他場所天花板高度超過 Y 公尺者，應採用放水型撒水頭。X、Y 分別為何？",{"webId":69,"year":70,"stem":71,"number":13},"fire-107-1-water-chemical-003",107,"水霧滅火設備之水源容量規定，下列何者正確？",1785123168196]