[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-107-1-alarm-evacuation-001":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":26,"sameNumber":52,"hasEssay":25},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":12,"stem":13,"options":14,"answer":19,"answerNote":20,"images":21,"imagesPending":22,"lawTimestamp":11,"explanation":23,"explanationDeep":24,"freq":12,"indexable":25},"fire-107-1-警報與避難系統消防安全設備概要-001","fire-107-1-alarm-evacuation-001",107,1,"依各類場所消防安全設備設置標準規定，除供甲類場所、地下建築物、高層建築物或應設置偵煙式探測器之場所外，若要以自動撒水設備免設火警自動警報設備，有關密閉型撒水頭之規定，下列那一項正確？",{"A":15,"B":16,"C":17,"D":18},"限使用標示攝氏溫度 75 度以下，動作時間 60 秒以上之密閉型撒水頭","限使用標示攝氏溫度 75 度以下，動作時間 60 秒以內之密閉型撒水頭","限使用標示攝氏溫度 75 度以下，動作時間 90 秒以內之密閉型撒水頭","限使用標示攝氏溫度 95 度以下，動作時間 60 秒以內之密閉型撒水頭","B",null,[],false,"本題考點：應設火警自動警報設備之場所，因已設自動撒水等滅火設備而得免設時，密閉型撒水頭的要件。\n【正解理由】依《各類場所消防安全設備設置標準》關於火警自動警報設備應設場所之免設但書規定，除供甲類場所、地下建築物、高層建築物或應設置偵煙式探測器之場所外，如已依本標準設置自動撒水、水霧或泡沫滅火設備者，在該有效範圍內得免設火警自動警報設備，而所用者限使用標示攝氏溫度七十五度以下、動作時間六十秒以內之密閉型撒水頭。溫度是上限、時間也是上限，兩要件須同時成立，故選 B。\n【逐項排除】\n(A) 溫度要件正確，但把動作時間寫成六十秒以上，方向完全相反；動作愈慢愈無法替代探測器的早期報知。\n(B) 標示攝氏溫度七十五度以下且動作時間六十秒以內，兩項要件皆與免設規定相符，為正確敘述。\n(C) 溫度要件正確，動作時間卻放寬為九十秒以內，已超過六十秒的上限，報知時效不足，不得據以免設。\n(D) 動作時間正確，但標示溫度放寬到九十五度以下，感熱門檻過高，撒水頭將延遲動作，同樣不符要件。\n【記憶點】免設要件記「七十五度以下、六十秒以內」——溫度要低、動作要快，撒水頭才頂得住警報設備的角色。","撒水頭之所以能替代火警自動警報設備，關鍵在《各類場所消防安全設備設置標準》第 51 條：自動撒水設備應裝置適當之流水檢知裝置，且撒水頭或一齊開放閥開啟放水時，即發出警報。放水即報警，功能上補起了偵知與報知這一段鏈路。但密閉型撒水頭是靠感熱元件熔解或玻璃球破裂而動作，反應必然慢於專責的探測器，法規因此用標示溫度七十五度以下壓低動作門檻、用動作時間六十秒以內限制感熱延遲，兩個數值合起來，就是把撒水頭的感知性能拉到堪與探測器比擬的最低要求。\n排除清單同樣有脈絡可循：甲類場所供公眾使用、在場人員不特定；地下建築物排煙與避難路徑受限；高層建築物有垂直延燒與長距離避難問題；應設偵煙式探測器之場所本就要求偵知煙而非熱。這四類場所的致命風險都落在早期偵知，靠溫度動作的撒水頭無法取代，故不得適用免設。\n第 7 條把各類場所消防安全設備分為滅火設備、警報設備、避難逃生設備、消防搶救上之必要設備，以及其他經中央主管機關認定之消防安全設備五類；本題規定屬於以滅火設備的附帶報知機能替代警報設備的少數例外，命題最愛考的就是那四類不得適用的場所，以及把七十五度與六十秒的方向或數值悄悄改動的陷阱。\n第 51 條的其他內容也常一併命題：各樓層之樓地板面積在三千平方公尺以下者，流水檢知裝置裝設一套，超過三千平方公尺者裝設二套；上下二層各層撒水頭數量在十個以下，且設有火警自動警報設備者，得二層共用；無隔間之樓層內，三千平方公尺得增為一萬平方公尺；並附設制水閥，其高度距離樓地板面在一點五公尺以下零點八公尺以上。免設是以「有效範圍」為界，撒水設備涵蓋不到的部分仍須設置警報設備。\n易混淆對照：密閉型撒水頭靠自身感熱動作，開放式撒水設備則須由感知撒水頭或探測器連動一齊開放閥啟動，後者本就仰賴探測系統，自不生以撒水頭替代警報設備的問題。",true,[27,32,36,40,44,48],{"webId":28,"stem":29,"number":30,"year":31,"session":12},"fire-106-1-alarm-evacuation-040","有關出口標示燈具閃滅或音聲引導功能者，依規定下列何者錯誤？",40,106,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-alarm-evacuation-002","差動式分布型探測器為熱半導體式時，裝接於一個檢出器之感熱器數量，下列何者正確？",2,{"webId":37,"stem":38,"number":39,"year":31,"session":12},"fire-106-1-alarm-evacuation-039","具有效採光，且直接面向室外之通道或走廊居室得免設緊急照明；所謂有效採光面積應達該居室樓地板面積多少比率方得免設？",39,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-alarm-evacuation-003","下列何者非屬定溫式探測器可裝設場所？",3,{"webId":45,"stem":46,"number":47,"year":31,"session":12},"fire-106-1-alarm-evacuation-038","依各類場所消防安全設備設置標準規定，避難指標設於出入口裝設應距樓地板面的高度要求為多少？",38,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-alarm-evacuation-004","下列那一種探測器，不可以裝設於室內天花板或屋頂板高度 15 公尺以上未滿 20 公尺之空間？",4,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":12},"fire-111-1-alarm-evacuation-001",111,"依各類場所消防安全設備設置標準規定，公共危險物品室內儲存場所總樓地板面積在多少平方公尺以上者，應設置火警自動警報設備？",{"webId":58,"year":59,"stem":60,"number":12},"fire-110-1-alarm-evacuation-001",110,"下列有關建築物火警分區之劃定，何者符合各類場所消防安全設備設置標準的規定？",{"webId":62,"year":63,"stem":64,"number":12},"fire-109-1-alarm-evacuation-001",109,"常開式之火警探測器信號回路，加設終端電阻之目的為何？",{"webId":66,"year":67,"stem":68,"number":12},"fire-108-1-alarm-evacuation-001",108,"某一新建建築物地面六層、地下二層，用途為辦公室，每層樓地板面積為 400 平方公尺，設置火警自動警報系統，假設 1 樓發生火警時，依各類場所消防安全設備設置標準規定，其鳴動方式為何？",{"webId":70,"year":31,"stem":71,"number":12},"fire-106-1-alarm-evacuation-001","某一 KTV 視聽歌唱場所設於大樓地下層，依規定樓地板面積如合計超過多少，應設置瓦斯漏氣火警自動警報設備？",1785123172153]