[{"data":1,"prerenderedAt":68},["ShallowReactive",2],{"q-fire-107-1-alarm-evacuation-003":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-警報與避難系統消防安全設備概要-003","fire-107-1-alarm-evacuation-003",107,1,3,"下列何者非屬定溫式探測器可裝設場所？",{"A":16,"B":17,"C":18,"D":19},"平時煙會滯留之場所","顯著高溫之場所","排放廢氣會大量滯留之場所","會結露之場所","C",null,[],false,"本題考點：探測器對裝置場所的適應性，判斷定溫式在哪一類惡劣環境不得作為選設機種。\n【正解理由】依《各類場所消防安全設備設置標準》關於探測器裝置場所適應性之規定，偵煙式局限型不得設置之各處所，須依其狀況改選適當之探測器；其中排放廢氣會大量滯留之場所，如停車空間、車道或貨物裝卸場，選設機種為差動式局限型、差動式分布型、補償式局限型或火焰式，並不包含定溫式。該類場所平時即因排氣而有溫度起伏與污損，定溫式須待周圍達到標稱動作溫度才動作，無法及時反應，故選 C。\n【逐項排除】\n(A) 平時煙會滯留之場所如廚房，偵煙式不得設置，正是改以防水型之定溫式或火焰式因應，定溫式屬可裝設場所。\n(B) 顯著高溫之場所為定溫式的典型適用場所，依第 120 條第三款，其應裝設在平時之最高周圍溫度比標稱動作溫度低攝氏二十度以上之處。\n(C) 排放廢氣會大量滯留之場所不在定溫式選設之列，係本題所問之非屬可裝設場所，為正解。\n(D) 會結露之場所可選用防水型之定溫式或補償式局限型，定溫式仍屬可裝設場所。\n【記憶點】定溫式怕的是「溫度上不去」，高溫、油煙、結露都能用，唯獨排放廢氣滯留處要交給差動式或火焰式。","定溫式探測器以雙金屬片、易熔絕緣物或熱敏元件為感熱媒介，須待周圍溫度達到標稱動作溫度才動作，屬絕對溫度型；差動式則量測單位時間內的溫升率，屬相對變化型。兩者的場所適應性差異全由此而來：廚房油煙、結露、顯著高溫這類平時溫度偏高或環境濕污的場所，差動式容易因蒸氣或短時溫升而非火災性動作，定溫式反而穩定；反之在排放廢氣大量滯留之處，溫度長期偏高又持續波動，定溫式的標稱動作溫度若設得高則反應遲鈍、設得低又頻繁誤動，故改由差動式或火焰式擔綱。\n有效探測範圍也要一併記。第 120 條附表載明，裝置面高度未滿四公尺、防火構造建築物時，定溫式特種為七十平方公尺、一種為六十平方公尺、局限型二種僅二十平方公尺；同條件下差動式局限型一種為九十平方公尺、二種為七十平方公尺。定溫式的數字明顯較小，代表同樣面積要裝設更多個，這也是高溫場所探測器密度偏高的由來。同條第三款另定，具二種以上標稱動作溫度者，應設在平時之最高周圍溫度比最低標稱動作溫度低攝氏二十度以上處。\n火焰式的設置條件見第 124 條：裝設於天花板、樓板或牆壁；距樓地板面一點二公尺範圍內之空間，應在探測器標稱監視距離範圍內；不得設在有障礙物妨礙探測火災發生處；並設在無日光照射之處，但設有遮光功能可避免探測障礙者不在此限。挑機種時，火焰式常是高溫、廢氣與挑高空間的替代解。\n定溫式的另一個常考出場點在滅火設備側：第 52 條規定開放式自動撒水設備之自動啟動裝置，感知撒水頭或探測器動作後能啟動一齊開放閥及加壓送水裝置，其探測器使用定溫式一種或二種，並依第 120 條規定設置，每一放水區域至少一個。可見定溫式不只用於火警自動警報設備，也被指定為開放式撒水設備的啟動元件，理由同樣是它在舞臺等溫度變化大的空間不易非火災性動作。\n記憶口訣：高溫、油煙、結露找定溫；廢氣滯留找差動或火焰。",true,[28,32,36,39,43,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-alarm-evacuation-002","差動式分布型探測器為熱半導體式時，裝接於一個檢出器之感熱器數量，下列何者正確？",2,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-alarm-evacuation-004","下列那一種探測器，不可以裝設於室內天花板或屋頂板高度 15 公尺以上未滿 20 公尺之空間？",4,{"webId":37,"stem":38,"number":12,"year":11,"session":12},"fire-107-1-alarm-evacuation-001","依各類場所消防安全設備設置標準規定，除供甲類場所、地下建築物、高層建築物或應設置偵煙式探測器之場所外，若要以自動撒水設備免設火警自動警報設備，有關密閉型撒水頭之規定，下列那一項正確？",{"webId":40,"stem":41,"number":42,"year":11,"session":12},"fire-107-1-alarm-evacuation-005","有一地下三層地上十層之建築物，總樓地板面積 5000 平方公尺，若起火樓層位於三樓時，下列那一樓層火警自動警報設備須鳴動？",5,{"webId":44,"stem":45,"number":46,"year":47,"session":12},"fire-106-1-alarm-evacuation-040","有關出口標示燈具閃滅或音聲引導功能者，依規定下列何者錯誤？",40,106,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-alarm-evacuation-006","下列何種使用瓦斯之場所，應設置瓦斯漏氣火警自動警報設備？",6,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-003",110,"建築物有某一樓層樓地板面積 900 平方公尺且設置之避難方向指示燈均為 C 級，該樓層最有可能為下列何種用途？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-003",109,"瓦斯對於空氣之比重大於 1 時，其瓦斯漏氣檢知器應設於距瓦斯燃燒器具水平距離多少公尺以內？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-alarm-evacuation-003",108,"用途為補習班，居室樓地板面積 300 平方公尺，採用有效通風方式檢討，其排煙口設於天花板下方 80 公分內，試問有效通風面積最少須要多少平方公尺以上方可符合規定？",{"webId":66,"year":47,"stem":67,"number":13},"fire-106-1-alarm-evacuation-003","裝設緊急廣播設備之建築物之規定，下列何者錯誤？",1785123172179]