[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-107-1-alarm-evacuation-013":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-警報與避難系統消防安全設備概要-013","fire-107-1-alarm-evacuation-013",107,1,13,"依各類場所消防安全設備設置標準規定，火警自動警報設備之配線，除依屋內線路裝置規則外，其電源回路導線間及導線與大地間之絕緣電阻值，以直流 250 伏特額定之絕緣電阻計測定，對地電壓在 150 伏特以下者，應該在多少 MΩ 以上？",{"A":16,"B":17,"C":18,"D":19},"0.1 MΩ","0.2 MΩ","0.3 MΩ","0.4 MΩ","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》火警自動警報設備配線之絕緣電阻規定。\n【正解理由】依《各類場所消防安全設備設置標準》關於火警自動警報設備配線之規定，電源回路導線間及導線與大地間之絕緣電阻值，以直流二百五十伏特額定之絕緣電阻計測定，對地電壓在一百五十伏特以下者，在零點一ＭΩ以上；對地電壓超過一百五十伏特者，在零點二ＭΩ以上。題目設定為對地電壓 150 伏特以下，故選 A。\n【逐項排除】\n(A) 0.1 MΩ 即對地電壓 150 伏特以下者之法定下限值，與條文相符。\n(B) 0.2 MΩ 是對地電壓「超過」150 伏特者的規定值，本題條件不符，屬對地電壓分界的典型陷阱。\n(C) 0.3 MΩ 法規未定此值，屬自創數值。\n(D) 0.4 MΩ 同樣非法定值，數值愈拉高愈偏離條文。\n【記憶點】火警配線絕緣電阻看對地電壓：150 伏特以下 0.1ＭΩ、超過者 0.2ＭΩ，量測一律用直流 250 伏特。","絕緣電阻的物理意義：導線間或導線對大地間的絕緣一旦劣化，就會出現漏電流，輕則使回路電壓下降造成探測器不動作，重則短路而讓整個火警分區失效。以直流二百五十伏特額定之絕緣電阻計測定，用意是在遠高於回路工作電壓的條件下驗證絕緣品質，讓潛在劣化提早顯現。\n數值分層的邏輯：對地電壓一百五十伏特以下者要求零點一ＭΩ以上，超過一百五十伏特者要求零點二ＭΩ以上——電壓愈高，同樣的絕緣劣化造成的漏電流愈大，故要求加倍。一百五十伏特這個分界，正好把常見的一一○伏特系統與二二○伏特以上系統分開。此外，探測器回路導線間及導線與大地間之絕緣電阻值，同樣以直流二百五十伏特額定之絕緣電阻計測定，每一火警分區在零點一ＭΩ以上。\n易混淆數值對照：同屬警報設備，《各類場所消防安全設備設置標準》第 131 條規定火警警鈴之電鈴絕緣電阻以直流二百五十伏特額定之絕緣電阻計測定，在二十ＭΩ以上——那是單一機器內部繞組的絕緣，量級與整條配線回路完全不同，考題最愛把 0.1 與 20 互換。瓦斯漏氣火警自動警報設備之配線則改以直流五百伏特額定之絕緣電阻計測定，電阻值同樣是零點一／零點二ＭΩ的分層，差別在測定電壓。\n相關考點連結：第 131 條同時規定火警警鈴電壓到達規定電壓之百分之八十時能即刻發出音響、在規定電壓下離開火警警鈴一百公分處所測得音壓在九十分貝以上，這組「250 伏特、20ＭΩ、100 公分、90 分貝、80%」數值常一併出題。第 131 條並要求警鈴音響應有別於建築物其他音響，除報警外不得兼作他用，且依本章第三節設有緊急廣播設備時得免設火警警鈴。整理時可把「絕緣電阻」與「回路電阻」分開理解：絕緣電阻量的是電有沒有漏掉，值愈大愈好、故訂下限；回路電阻量的是訊號送不送得到，值愈小愈好、故訂上限。兩者方向相反，是這類數值題最常被混用的地方。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-alarm-evacuation-012","有關光電式分離型探測器光軸，下列設置規定何者正確？",12,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-alarm-evacuation-014","依各類場所消防安全設備設置標準規定，火警受信總機若為壁掛型，總機操作開關距離樓地板面之高度，應該為多少公尺範圍？",14,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-alarm-evacuation-011","依各類場所消防安全設備設置標準規定，火警受信總機、中繼器及偵煙式探測器，有設定蓄積時間時，其蓄積時間之合計，每一火警分區在多少秒以下？",11,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-alarm-evacuation-015","有關緊急供電系統之電源，下列何者錯誤？",15,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-alarm-evacuation-010","依各類場所消防安全設備設置標準第 23 條規定，各類場所均應設置避難指標。但設有以下那一個設備時，在其有效範圍內，得免設置避難指標？",10,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-alarm-evacuation-016","避難器具之設置數量與場所之收容人數有很大的關係，依各類場所消防安全設備設置標準規定，有關醫療機構（醫院、診所）候診室之收容人數之計算，應以各候診室之樓地板面積和除多少平方公尺所得之數，做為候診室之收容人數？",16,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-013",110,"容易受風影響之場所（如大廳、禮拜堂、大樓頂上之機械室等），依消防安全設備及必要檢修項目檢修基準之規定，可在下列何種探測器中進行選設？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-013",109,"無線電通信輔助設備設置之規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-alarm-evacuation-013",108,"有關避難器具之外觀試驗，下列何者不屬於外觀試驗？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-013",106,"集合住宅計算收容人數以設置避難器具時，每戶收容人數以多少人計算？",1785123172277]