[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-107-1-alarm-evacuation-026":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-警報與避難系統消防安全設備概要-026","fire-107-1-alarm-evacuation-026",107,1,26,"依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，有關電源回路之配線耐燃保護，若電線裝於金屬導線管槽內，並埋設於防火構造物之混凝土內，混凝土保護厚度應為多少毫米以上？",{"A":16,"B":17,"C":18,"D":19},"10 毫米","20 毫米","30 毫米","40 毫米","B",null,[],false,"本題考點：緊急供電系統中「電源回路」配線之耐燃保護作法，以及埋設於混凝土時所需的保護厚度。\n【正解理由】依《各類場所消防安全設備設置標準》關於緊急供電系統配線之規定，電源回路之配線應施予耐燃保護，其作法之一為電線裝於金屬導線管槽內，並埋設於防火構造物之混凝土內，混凝土保護厚度為二十毫米以上；本題所問即為此一厚度，故選 B。\n【逐項排除】\n(A) 10 毫米未達規定厚度，混凝土的隔熱厚度不足以在火害持續時保護管槽內的導線。\n(B) 20 毫米與規定之混凝土保護厚度相符，是本題所求的最小值；規定寫的是「二十毫米以上」，故 20 毫米恰為合格下限，再薄即不成立。\n(C) 30 毫米雖較規定更厚，但題目問的是法規所定之最低保護厚度，並非任意加厚後的數值。\n(D) 40 毫米同屬超出規定的數值，法規並未以此為界。\n【記憶點】「耐燃埋混凝土，保護厚 20 毫米」；另兩種耐燃作法是 MI 電纜或耐燃電纜直接敷設，以及中央主管機關指定之耐燃保護裝置。","緊急供電系統的配線分成耐燃保護與耐熱保護兩級，分野在回路的重要性：電源回路一旦燒斷，該設備整組失效，故要求較高的耐燃；標示燈回路及控制回路受損主要影響顯示與操作，故要求耐熱即可。耐燃保護有三種作法——電線裝於金屬導線管槽內並埋設於防火構造物之混凝土內，混凝土保護厚度二十毫米以上，但在使用不燃材料建造且符合建築技術規則防火區劃規定之管道間得免埋設；使用 MI 電纜或耐燃電纜時，得按電纜裝設法直接敷設；其他經中央主管機關指定之耐燃保護裝置。耐熱保護則為電線於金屬導線管槽內裝置、使用 MI 電纜耐燃電纜或耐熱電線電纜時得直接敷設、其他經中央主管機關指定之耐熱保護裝置。\n可與第 176 條對照：緊急照明設備除內置蓄電池式外，緊急照明燈之電源回路原則上施予耐燃保護，但天花板及其底材使用不燃材料時，得施予耐熱保護——這是少見的條件式降級，命題率高。\n電源本身的規定見第 237 條：緊急電源使用符合 CNS 一○二○四規定之發電機設備、一○二○五規定之蓄電池設備或具有相同效果之設備；裝置切換開關，於常用電源切斷時自動切換供應電源至緊急用電器具，常用電源恢復時自動恢復；發電機並裝設適當開關或連鎖機件，以防止向正常供電線路逆向電力；裝設發電機及蓄電池之處所為防火構造，設於屋外並有防水措施者不在此限；蓄電池設備充電電源之配線應設專用回路，開關上有明顯標示。\n※ 法規時點提醒：本題所涉之緊急供電系統配線條文，於本場考試（107 年 6 月 3 日）後曾經修正，現行條文所依循者已改稱「用戶用電設備裝置規則」，故本詳解採章節級引用、不標註條號。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-alarm-evacuation-025","有一飯店，其三樓之樓地板面積為 1200 平方公尺，依各類場所消防安全設備設置標準規定，於設置出口標示燈時，除應使用 A 級或 B 級外，出口標示燈標示面光度應在多少燭光（cd）以上？",25,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-alarm-evacuation-027","依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，緊急用電源回路及操作回路，應使用多少伏特耐熱絕緣電線，或同等耐熱效果以上之電線？",27,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-alarm-evacuation-024","P 型受信總機採用數個分區共用一公用線方式配線時，該公用線供應之分區數，依各類場所消防安全設備設置標準規定，不得超過多少個？",24,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-alarm-evacuation-028","依各類場所消防安全設備檢修及申報作業基準規定，對火警自動警報設備進行二信號性能檢查時，有關判定方法，下列敘述何者錯誤？",28,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-alarm-evacuation-023","自居室任一點易於觀察識別其主要出入口，且與主要出入口之步行距離符合規定者，得免設出口標示燈、避難方向指示燈或避難指標，試問下列何者不得免設？",23,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-alarm-evacuation-029","依各類場所消防安全設備設置標準規定，有關標示設備之敘述，何者正確？",29,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-026",110,"對於單相交流 110 V 之緊急電源插座進行外觀及性能檢查時，下列何者與消防安全設備及必要檢修項目檢修基準之規定不同？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-026",109,"有關緊急廣播設備配線之設置，除依屋內線路裝置規則外，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-alarm-evacuation-026",108,"依各類場所消防安全設備設置標準規定，裝置面高度 10 公尺者，不可選擇下列何種探測器設置？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-026",106,"樓梯或斜坡通道以外之場所，廣播區域之殘響時間在 3 秒以上時，揚聲器之裝設需符合 r = 3 \u002F 4 QSα\u002Fπ (1 −α) 之計算公式，S 的定義為何？",1785123172400]