[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-107-1-alarm-evacuation-035":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-警報與避難系統消防安全設備概要-035","fire-107-1-alarm-evacuation-035",107,1,35,"依各類場所消防安全設備檢修及申報作業基準規定，緊急電源插座為單相交流 110 V 者，應用額定 150 V， X 安培之接地型插座。三相交流 220 V 者則適用額定 250 V，Y 安培接地型插座，並確認應無變形、損傷、顯著腐蝕或異物阻塞等，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"X = 10；Y = 20","X = 10；Y = 30","X = 15；Y = 30","X = 15；Y = 40","C",null,[],false,"本題考點：緊急電源插座外觀檢查中，單相交流與三相交流插座之額定電壓與額定電流規格。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第二十三章緊急電源插座之外觀檢查，插座之判定方法明定「緊急電源插座為單相交流 110V 用者，應依圖 23-1 所示（額定 150V，15A）之接地型插座。三相交流 220V 用則適用圖 23-2 所示（額定 250V，30A）接地型插座」，可知 X＝15、Y＝30，故選 C。此與《各類場所消防安全設備設置標準》第 191 條所定「緊急電源插座之電流供應容量為交流單相一百一十伏特（或一百二十伏特）十五安培」相互一致。\n【逐項排除】\n(A) X＝10 與設置標準第 191 條所定十五安培之供應容量不符，Y＝20 亦非基準所列三相 250V 插座的 30A 額定。\n(B) Y＝30 與三相之規定相符，但 X＝10 低於單相插座應有的 15A 額定，兩者須同時成立，整組仍不正確。\n(C) X＝15、Y＝30 與基準所列（額定 150V，15A）及（額定 250V，30A）完全相符，為本題應選者。\n(D) X＝15 部分正確，惟 Y＝40 非基準所列數值，三相交流 220V 用者為額定 250V、30A 之接地型插座。\n【記憶點】單相 110V 配額定 150V／15A，三相 220V 配額定 250V／30A——電壓、電流都比使用值往上抓一級。","緊急電源插座是消防人員到場後在樓梯間、緊急昇降機間取用電源的設備，供投光器照明、破壞器材、排煙機等使用，規格必須高於實際負載一級才安全。《各類場所消防安全設備設置標準》第 191 條定其電流供應容量為交流單相一百一十伏特（或一百二十伏特）十五安培，容量約一點五瓩以上；插座為接地型，裝設高度距離樓地板一公尺以上一點五公尺以下，且裝設二個於崁裝式保護箱內；保護箱長邊二十五公分、短邊二十公分以上，以厚度一點六毫米以上鋼板或同等性能之不燃材料製成，箱內設有防止插頭脫落之 L 型或 C 型護鉤，箱蓋為易於開閉之構造並須接地，箱蓋標示緊急電源插座字樣每字二平方公分以上，上方並設紅色表示燈。\n供電側同條規定：應從主配電盤設專用回路，各層至少二回路以上之供電線路，每一回路連接插座數在十個以下，專用回路不得設漏電斷路器（避免搶救中跳電），各插座另設容量一百一十伏特、十五安培以上之無熔絲斷路器，並連接至緊急供電系統。\n額定電壓高於使用電壓是電氣器材通則：110V 用取額定 150V、220V 用取額定 250V，留出突波與電壓變動的餘裕；額定電流則對應回路斷路器容量，單相 15A、三相 30A。同章性能檢查另含插頭是否可輕易拔出插入、開關器開關性能是否正常、以三用電表確認單相與三相端子電壓是否在規定範圍，以及三相 220V 連接電動機時應以相位計確認為正回轉（右向回轉）。※ 該基準線上可得之最早版本為 109.08.21，晚於本題考試日，個別數值仍以考試當時版本為準。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-alarm-evacuation-034","依各類場所消防安全設備檢修及申報作業基準規定，緊急照明設備在建築物總樓地板面積為 5000 平方公尺時，檢查緊急電源容量能否持續 30 分鐘之檢查數量應在多少個以上？",34,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-alarm-evacuation-036","依各類場所消防安全設備設置標準規定，下列處所何者不得免設緊急照明設備？",36,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-alarm-evacuation-033","依各類場所消防安全設備檢修及申報作業基準規定，檢查檢知器時，使用「加瓦斯試驗器」進行加瓦斯測試，對空氣之比重未滿一者應使用何種物質？",33,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-alarm-evacuation-037","設置避難器具時，標示其設置位置、使用方法並設置指標，下列規定何者錯誤？",37,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-alarm-evacuation-032","依各類場所消防安全設備設置標準規定，下列何者非屬消防搶救上之必要設備種類？",32,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-alarm-evacuation-038","依各類場所消防安全設備設置標準規定，差動式分布型及偵煙式探測器之探測區域，指探測器裝置面之四周以淨高多少公分以上之樑或類似構造體區劃包圍者？",38,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-035",110,"依各類場所消防安全設備設置標準規定，避難指標設於走廊或通道時，自走廊或通道任一點至指標之步行距離在多少公尺以下？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-035",109,"有關避難器具開口部周圍狀況外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-alarm-evacuation-035",108,"依各類場所消防安全設備設置標準規定，在應設排煙設備之場所，有關其排煙設備設置之描述，下列何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-035",106,"執行檢修時，在室溫 15℃狀態下，使用加熱試驗器進行差動式局限型第二種探測器之性能檢查時，其動作時間應在多少秒內方為正常？",1785123172524]