[{"data":1,"prerenderedAt":68},["ShallowReactive",2],{"q-fire-107-1-alarm-evacuation-039":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-警報與避難系統消防安全設備概要-039","fire-107-1-alarm-evacuation-039",107,1,39,"依各類場所消防安全設備設置標準規定，緊急廣播設備之啟動裝置應符合 CNS 10522 之規定，且設在距樓地板高度 X 公尺以上 Y 公尺以下範圍內，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"X + Y = 1.9","X + Y = 2.1","X + Y = 2.3","X + Y = 2.5","C",null,[],false,"本題考點：緊急廣播設備啟動裝置的設置高度範圍，以及與其他操作類裝置高度的區辨。\n【正解理由】依《各類場所消防安全設備設置標準》第 136 條，緊急廣播設備之啟動裝置應符合 CNS 一○五二二之規定，並「設在距樓地板高度零點八公尺以上一點五公尺以下範圍內」。因此 X＝0.8、Y＝1.5，X＋Y＝0.8＋1.5＝2.3，故選 C。\n【逐項排除】\n(A) X＋Y＝1.9 須為 0.8 公尺以上 1.1 公尺以下，其上限 1.1 公尺與第 136 條所定一點五公尺不符。\n(B) X＋Y＝2.1 對應 0.6 至 1.5 公尺；零點六公尺是第 138 條擴音機及操作裝置中座式操作者之操作開關高度，並非啟動裝置的下限。\n(C) X＋Y＝0.8＋1.5＝2.3，與第 136 條所定之設置高度範圍完全相符，為本題應選者。\n(D) X＋Y＝2.5 對應 1.0 至 1.5 公尺；一公尺以上一點五公尺以下是第 191 條緊急電源插座之裝設高度，不是啟動裝置的規定。\n【記憶點】手動操作類 0.8～1.5 公尺、座式操作 0.6 公尺起、緊急電源插座 1.0～1.5 公尺，三組高度分開記就不會互相污染。","緊急廣播設備的啟動裝置就是供發現火災者立即啟動廣播的裝置。第 136 條除高度外還有兩個常考點：各樓層任一點至啟動裝置之步行距離在五十公尺以下；各類場所第十一層以上之各樓層、地下第三層以下之各樓層或地下建築物，應使用緊急電話方式啟動——高樓層與深層地下的避難、搶救需要雙向確認火點資訊，單向按鈕並不足夠。\n零點八公尺以上一點五公尺以下這個範圍，是人站立時手部自然操作的高度帶，同一組數值在設置標準中反覆出現，最值得一起記的是第 138 條：擴音機及操作裝置應符合 CNS 一○五二二之規定，其操作開關距樓地板面之高度在零點八公尺以上（座式操作者為零點六公尺）一點五公尺以下，且操作裝置設於值日室等經常有人之處所，設有防災中心時設於該中心。相對地，第 191 條緊急電源插座的裝設高度為距離樓地板一公尺以上一點五公尺以下，下限拉高到一公尺；第 180 條連結送水管之出水口則為距樓地板面之高度在零點五公尺以上一點五公尺以下。\n第 138 條同時規定操作裝置與啟動裝置或火警自動警報設備動作連動，並標示所動作之樓層或區域、具有選擇必要樓層或區域廣播之性能、各廣播分區配線短路時應有短路信號之標示，這些性能要求常與本題的高度數值合併命題。至於條文開頭「應符合 CNS 一○五二二之規定」，指的是該 CNS 標準對緊急廣播設備之啟動裝置、擴音機及操作裝置所定之構造與性能要求，法規以引用標準的方式把它整套納入，屬於典型的「法規加 CNS」雙層規範體例，考題也常單獨把這個 CNS 編號拿出來問。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-alarm-evacuation-038","依各類場所消防安全設備設置標準規定，差動式分布型及偵煙式探測器之探測區域，指探測器裝置面之四周以淨高多少公分以上之樑或類似構造體區劃包圍者？",38,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-alarm-evacuation-040","依各類場所消防安全設備檢修及申報作業基準規定，緩降機應以測量下降距離及下降時間，計算出下降速度，最大下降速度應在每秒多少公分以內？",40,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-alarm-evacuation-037","設置避難器具時，標示其設置位置、使用方法並設置指標，下列規定何者錯誤？",37,{"webId":41,"stem":42,"number":12,"year":43,"session":12},"fire-108-1-alarm-evacuation-001","某一新建建築物地面六層、地下二層，用途為辦公室，每層樓地板面積為 400 平方公尺，設置火警自動警報系統，假設 1 樓發生火警時，依各類場所消防安全設備設置標準規定，其鳴動方式為何？",108,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-alarm-evacuation-036","依各類場所消防安全設備設置標準規定，下列處所何者不得免設緊急照明設備？",36,{"webId":49,"stem":50,"number":51,"year":43,"session":12},"fire-108-1-alarm-evacuation-002","特別安全梯的安全梯與緊急昇降機兼用時，其排煙機、進風機之排煙量、進風量須在每秒多少立方公尺以上？",2,[53,57,61,64],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-039",110,"依消防安全設備及必要檢修項目檢修基準，火焰式探測器進行性能檢查時，使用火焰探測器用動作試驗器，探測器應在多少時間內動作？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-039",109,"有關緊急照明設備之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":62,"year":43,"stem":63,"number":13},"fire-108-1-alarm-evacuation-039","依各類場所消防安全設備設置標準規定，下列何種場所不須設置緊急電源插座？",{"webId":65,"year":66,"stem":67,"number":13},"fire-106-1-alarm-evacuation-039",106,"具有效採光，且直接面向室外之通道或走廊居室得免設緊急照明；所謂有效採光面積應達該居室樓地板面積多少比率方得免設？",1785123172575]