[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-012":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-012","fire-107-1-fire-law-012",107,1,12,"依建築技術規則建築設計施工編之規定，經中央主管建築機關認定符合耐燃二級之材料，屬於下列何種建築材料？",{"A":16,"B":17,"C":18,"D":19},"不燃材料","耐火板","耐燃材料","防火構造","B",null,[],false,"本題考點：建築材料之耐燃等級與名稱對應，見《建築技術規則》建築設計施工編第 1 條用語定義中耐燃材料之分級規定。\n【正解理由】依《建築技術規則》建築設計施工編第 1 條用語定義，耐燃材料係指供建築物內部裝修之材料，於火災初期受高溫時，僅發生極少量之炭化、熔融、龜裂、破損等現象，且不易發煙及發生有害氣體者，並依中央主管建築機關認定之耐燃程度分為三級：耐燃一級為不燃材料、耐燃二級為耐火板、耐燃三級為耐燃材料。題目問耐燃二級所對應之建築材料名稱，即耐火板，故選 B。\n【逐項排除】\n(A) 不燃材料對應的是耐燃一級，屬最高等級，如混凝土、磚、玻璃、鋼鐵、石材等在火災高溫下幾乎不生燃燒現象者。\n(B) 耐火板正是耐燃二級所對應之名稱，指木絲水泥板、耐燃石膏板等經認定符合該級數者。\n(C) 耐燃材料在分級體系中對應耐燃三級，是三級中要求最寬鬆者，如耐燃合板、耐燃塑膠板等。\n(D) 防火構造指的是建築物構造體（牆壁、樑、柱、樓地板等）具一定防火時效之構造方式，屬構造層次而非內部裝修材料之耐燃等級。\n【記憶點】一級不燃、二級耐火板、三級耐燃材料，級數愈小愈耐燒。","耐燃分級管的是「內部裝修材料」，與防火時效管的「構造體」是兩套平行制度，混為一談是本題最大的失分原因。內部裝修材料之所以要分級，源自旅館、餐飲及娛樂場所火災的慘痛經驗：真正在火場中快速奪命的往往不是結構倒塌，而是天花板與牆面裝修材在火災初期迅速引燃、產生大量濃煙與有毒氣體，使能見度在數十秒內歸零。因此法規對裝修材料要求的重點不只是「難燒」，還包括「不易發煙」與「不發生有害氣體」，這也是耐燃材料定義文字中特別點出發煙與有害氣體的原因。\n三級體系可整理成：耐燃一級＝不燃材料（混凝土、磚、瓦、石材、鋼鐵、鋁、玻璃、水泥板等）；耐燃二級＝耐火板（木絲水泥板、耐燃石膏板等）；耐燃三級＝耐燃材料（耐燃合板、耐燃纖維板、耐燃塑膠板等）。記憶訣竅是「數字愈小、等級愈高、愈接近完全不燒」，而名稱上最容易錯的是耐燃三級竟然就叫「耐燃材料」，與上位概念同名，命題者幾乎每次都利用這個同名陷阱設誘答。\n與之對照的防火構造制度，是以構造體能維持多久不失去承重與區劃功能來分級，單位是時間（30 分鐘、1 小時、2 小時、3 小時），適用對象是牆、柱、樑、樓地板、屋頂與防火門窗。兩者的連動考點在於：建築物用途與樓層決定應採何種耐燃等級之內部裝修，例如供公眾使用場所之走廊、樓梯間等避難路徑，往往被要求採用等級較高之材料，因為那正是人員必須通過的空間。相關延伸考點還包括無窗戶居室之裝修限制與防焰物品（窗簾、地毯、布幕）之規定，後者屬《消防法》第 11 條體系，勿與耐燃分級混淆。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-011","依建築技術規則建築設計施工編之規定，所謂的集合住宅，係指具有共同基地及共同空間或設備，並有幾個住宅單位以上之建築物？",11,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-013","依各類場所消防安全設備檢修及申報作業基準之規定，各類場所之管理權人應於檢修完成後幾日內，分別填具消防安全設備檢修申報表及檢附消防安全設備檢修報告書，向當地消防機關申報？",13,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-010","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，易燃液體，係指在一大氣壓時，閃火點在攝氏多少度以下之液體？",10,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-014","依各類場所消防安全設備檢修及申報作業基準之規定，滅火器本體上端與樓地板面之距離，若滅火器未滿 18 公斤者應在多少公尺以下？",14,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-009","依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，販賣場所內設六類物品調配室者，調配室出入口應設置多少小時以上防火時效之防火門？",9,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-015","依各類場所消防安全設備檢修及申報作業基準之規定，進行密閉式撒水設備綜合檢查時，當以幫浦方式作為加壓送水裝置時，末端查驗管之放水壓力應在 a kgf／cm2 以上、b kgf／cm2 以下。a、b 各為何值？",15,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-012",111,"消防幫浦加壓送水裝置中，有關呼水裝置規定之敘述，下列何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-fire-law-012",110,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，有關公共危險物品及其製造、儲存場所之規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-fire-law-012",109,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關於供作六類物品製造場所或一般處理場所使用之建築物，一部分供作室內儲存場所儲存六類物品之數量在管制量 20 倍以下者，其牆壁、樑、柱、地板及上層之地板應為防火構造，且應具有多少小時以上防火時效？",{"webId":66,"year":67,"stem":68,"number":13},"fire-108-1-fire-law-012",108,"依據各類場所消防安全設備設置標準規定，設於儲槽之固定式泡沫滅火設備，下列何者係指供固定頂儲槽槽底注入泡沫法之放出口？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-012",106,"依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，下列何種公共危險物品，不得儲放室外儲存場所？",1785123159402]