[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-fire-law-035":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-消防法規概要-035","fire-107-1-fire-law-035",107,1,35,"依各類場所消防安全設備檢修及申報作業基準之規定，有關瓦斯漏氣火警自動警報設備性能檢查，下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"預備電源及緊急電源之檢查，預備電源之容量超過緊急電源時，得取代緊急電源","預備電源及緊急電源之檢查，充電回路使用阻抗器者，得以發熱來判斷是否異常","受信機及中斷器之通話裝置檢查，受信總機處相互間，設有對講機時，得以對講機取代電話機","受信機及中斷器之通話裝置檢查，同一居室設二台以上受信總機時，得免設通話裝置","B",null,[],false,"本題考點：《消防安全設備檢修及申報作業基準》中瓦斯漏氣火警自動警報設備性能檢查之判定要領,題目問「錯誤」者。\n【正解理由】依《消防安全設備檢修及申報作業基準》關於預備電源及緊急電源之性能檢查,充電回路使用「整流器」者,得以整流器之發熱狀況判斷是否異常;B 將整流器誤植為阻抗器,檢查對象的元件被替換,與基準文字不符,故選 B。\n【逐項排除】\n(A) 正確。基準明定預備電源之容量超過緊急電源時,得取代緊急電源,兩者功能相同且容量足夠即可互代,避免重複設置。\n(B) 錯誤。得以發熱判斷異常的是充電回路使用整流器的情形,而非阻抗器;整流器負責交流轉直流供電池浮充,異常時會出現不正常發熱,故以此為判定線索,為本題答案。\n(C) 正確。受信總機與中斷器之通話裝置檢查,若受信總機處相互間設有對講機,得以對講機取代電話機,通話功能已達成即認可。\n(D) 正確。同一居室設二台以上受信總機時,值勤人員可直接口頭聯絡,基準允許免設通話裝置。\n【記憶點】充電回路看「整流器」發熱,不是阻抗器;預備電源容量夠就能取代緊急電源。","瓦斯漏氣火警自動警報設備由檢知器、中斷器(中繼器)與受信總機組成,與火警自動警報設備最大的差異在偵測對象是可燃性氣體而非燃燒生成物,因此檢知器的裝設高度取決於氣體比重:比空氣輕的天然氣(主成分甲烷)檢知器裝於天花板附近,比空氣重的液化石油氣(丙烷、丁烷)檢知器裝於接近地面處,這是本設備最常被單獨命題的原理性考點。\n\n檢修基準把檢查分為外觀檢查、性能檢查與綜合檢查三層。外觀檢查看設置狀況、標示與外部損傷;性能檢查以萬用電表、加瓦斯試驗器等實測動作與電氣特性;綜合檢查則以實際加入試驗氣體確認整體連動。本題屬性能檢查層次,問的是判定要領的細節,這類題目的解法是抓住「檢查對象元件」與「判定線索」的配對關係,例如整流器對應發熱、蓄電池對應端子電壓與液面、繼電器對應接點導通,配對錯置即為錯誤選項。\n\n預備電源與緊急電源的互代規則,背後是避免重複投資的比例原則:兩者都是在常用電源停電時維持設備運作,若預備電源容量已涵蓋緊急電源所需的動作時間與負載,再另設一組並無實益。反過來說,緊急電源容量不得用來取代容量更大的預備電源,方向不可顛倒,這也是常見的反向命題。\n\n通話裝置的規定同樣依「功能是否已達成」判斷:設有對講機即可取代電話機,同一居室內有二台以上受信總機則根本不需要裝置輔助,因為人員可直接對話。掌握這種「目的導向」的解讀方式,即使條文細節記憶模糊,也能在選項間做出正確取捨。\n\n最後補一個複習方法:把瓦斯漏氣火警自動警報設備的檢修項目做成三欄表,左欄寫檢查對象(檢知器、中斷器、受信總機、預備電源、警報裝置),中欄寫檢查方法,右欄寫判定要領,錯誤選項幾乎都是把某一列的中欄或右欄橫向搬到別列,對照表一畫就無所遁形。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-fire-law-034","依各類場所消防安全設備設置標準之規定，下列何者非屬甲類場所？",34,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-fire-law-036","依防火牆及防火水幕設置基準之規定，防火水幕設備之水源應連結加壓送水裝置，下列敘述何者錯誤？",36,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-fire-law-033","依各類場所消防安全設備設置標準之規定，防災中心樓地板面積應在多少平方公尺以上？",33,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-fire-law-037","依防火牆及防火水幕設置基準之規定，有一儲槽其水平剖面最大半徑為 5 公尺，內裝有公共危險物品，該公共危險物品之閃火點為攝氏八十度，則假想火面高度為多少公尺？",37,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-fire-law-032","依各類場所消防安全設備設置標準之規定，有關無線電通信輔助設備，下列敘述何者錯誤？",32,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-fire-law-038","依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，呼水裝置應有多少公升以上之有效儲存量？",38,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-035",111,"某合法 KTV 視聽歌唱場所經當地消防機關會勘通過依法取得室內裝修許可，依照消防安全設備檢修及申報辦法規定，自該室內裝修許可核發之日期起算，距申報期限在多少個月以內，免辦理當次檢修及申報備查？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-fire-law-035",110,"某幼兒園經當地消防機關會勘通過依法取得使用執照，依消防安全設備檢修及申報辦法規定，自該使用執照證明文件核發之日期起算，距申報期限在幾個月內，免辦理當次檢修及申報備查？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-fire-law-035",109,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，裝設消防撒水幫浦，設計水量為 600 公升\u002F分，其設計揚程為 50 公尺；當揚水量在 900 公升\u002F分時，其揚程需調校在下列何標準值以上，方能判定合格？",{"webId":66,"year":67,"stem":68,"number":13},"fire-108-1-fire-law-035",108,"依建築技術規則建築設計施工編規定，女兒牆之高度應在多少公尺以內？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-035",106,"下列有關建築物消防安全設備竣工查驗程序規定之敘述，何者錯誤？",1785123159659]