[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-water-chemical-012":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-水與化學系統消防安全設備概要-012","fire-107-1-water-chemical-012",107,1,12,"設置乾粉滅火設備時，全區及局部放射之緊急電源應為自用發電設備或蓄電池設備，其容量應能使設備有效動作多久以上？",{"A":16,"B":17,"C":18,"D":19},"20 分鐘","30 分鐘","45 分鐘","60 分鐘","D",null,[],false,"本題考點：乾粉滅火設備緊急電源的容量標準，以及各類消防安全設備電源動作時間的橫向比較。\n【正解理由】依《各類場所消防安全設備設置標準》第 98 條，乾粉滅火設備之緊急電源準用第九十五條規定；第 95 條明定全區及局部放射方式之緊急電源，應採用自用發電設備或蓄電池設備，其容量應能使該設備有效動作一小時以上。一小時即 60 分鐘，故選 D。氣體與乾粉系統採全區、局部放射時，牽涉開口部自動關閉、音響警報、遲延與放射表示等連動機能，停電後仍須維持整套動作，電源時間因而訂得比水系統長。\n【逐項排除】\n(A) 20 分鐘是出口標示燈及避難方向指示燈緊急電源的一般容量（第 155 條），不是乾粉設備的標準。\n(B) 30 分鐘為室內消防栓設備緊急電源（第 38 條）與緊急照明設備（第 177 條）之容量。\n(C) 45 分鐘出現在公共危險物品等場所的室內消防栓設備（第 209 條第二項），屬加嚴規定，仍非本題所問。\n(D) 60 分鐘正確，即第 95 條所定「有效動作一小時以上」。\n【記憶點】乾粉與二氧化碳全區、局部放射一律「一小時」，水系統三十分鐘，出口標示燈二十分鐘。","緊急電源時間是本科典型的表格題，按設備群組排一次就不易錯。氣體與乾粉系統最長：全區及局部放射方式依第 95 條為一小時，乾粉依第 98 條準用之，電源種類可選自用發電設備或蓄電池設備。水系統次之：室內消防栓設備依第 38 條，應使用發電機設備或蓄電池設備，供電容量應供其有效動作三十分鐘以上；緊急照明設備依第 177 條亦為三十分鐘，但採蓄電池設備與緊急發電機併設方式時，容量應能使其持續動作分別為十分鐘及三十分鐘以上。\n警報系統最短且限定電源種類：火警自動警報設備依第 128 條，緊急電源應使用蓄電池設備，容量能使其有效動作十分鐘以上；瓦斯漏氣火警自動警報設備依第 145 條，蓄電池設備容量應能使二回路有效動作十分鐘以上、其他回路能監視十分鐘以上。限定蓄電池而不許單靠發電機，是因為警報須在停電瞬間無間斷維持，而發電機起動需時。\n避難逃生方面，出口標示燈及避難方向指示燈依第 155 條為二十分鐘，但總樓地板面積在五萬平方公尺以上、高層建築物總樓地板面積在三萬平方公尺以上、地下建築物總樓地板面積在一千平方公尺以上者，其主要避難路徑之容量應在六十分鐘以上，並得採蓄電池設備及緊急發電機併設方式；所謂主要避難路徑指通往戶外之出入口、通往直通樓梯之出入口、通往該出入口之走廊或通道及直通樓梯。\n公共危險物品等場所整體加嚴，依第 209 條，室內消防栓設備之緊急電源除準用第 38 條外，供電容量應供其有效動作四十五分鐘以上。命題常把時間與電源種類交叉替換，逐項核對即可拆解。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-water-chemical-011","加壓式乾粉滅火設備，於啟動裝置動作後，為使儲存容器壓力達設定壓力始開啟放出閥，應設置何種裝置？",11,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-water-chemical-013","有關二氧化碳滅火設備配管之設置規定，下列何者正確？",13,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-water-chemical-010","第一種室內消防栓採用消防幫浦做為加壓送水裝置時，假設水帶摩擦損失水頭為 3 m，配管磨擦損失水頭為 7 m，落差為 30 m，則依規定，幫浦的全揚程應為多少公尺？",10,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-water-chemical-014","二氧化碳滅火系統採全區放射方式高壓式系統，共設有 24 瓶儲存容器，進行綜合檢查時，放射試驗所需之藥劑量，應為下列何者？",14,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-water-chemical-009","某一學校教學大樓每一樓層皆設有第一種室內消防栓 3 具，則其水源容量應為多少立方公尺？",9,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-water-chemical-015","二氧化碳滅火系統進行性能檢查時，音響警報之判定方法為距警報裝置 X 公尺處之音量應在 Y 分貝以上，其中 X、Y 應為下列何者？",15,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-012",111,"有關水霧滅火設備，依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-water-chemical-012",110,"進行乾粉滅火設備性能檢查時，對於滅火藥劑檢查注意事項，溫度及濕度超過多少以上時，應暫停檢查？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-water-chemical-012",109,"消防水系統設置呼水裝置時，其溢水用排水管口徑應在多少尺寸以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-108-1-water-chemical-012",108,"主成分為碳酸氫鉀及尿素化合物之乾粉滅火藥劑，採全區放射方式時，每立方公尺防護區域所需滅火藥劑量為多少公斤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-012",106,"簡易自動滅火設備進行性能檢查時，其蓄壓式滅火藥劑量應與標示重量差異在何範圍以內？",1785123167870]