[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-107-1-water-chemical-037":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-107-1-水與化學系統消防安全設備概要-037","fire-107-1-water-chemical-037",107,1,37,"有關撒水頭設置之敘述，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"設於夜總會表演場所舞臺之撒水頭，任一點至撒水頭之水平距離在 2.1 公尺以下","公共危險物品等場所設置自動撒水設備，防護對象任一點至撒水頭之水平距離在 2.1 公尺以下","高架儲存倉庫中，設於貨架之撒水頭，任一點至撒水頭之水平距離在 2.5 公尺以下，並以平行方式設置","一防火構造之餐廳設置一般反應型撒水頭（第二種感度），各層任一點至撒水頭之水平距離在 2.3 公尺以下","D",null,[],false,"本題考點：撒水頭水平距離的四組數值——表演場所舞臺、公共危險物品場所、高架儲存倉庫貨架，以及一般場所依感度型式與建築構造的分級。\n【正解理由】依《各類場所消防安全設備設置標準》關於撒水頭配置之規定，一般場所使用一般反應型撒水頭（第二種感度）時，各層任一點至撒水頭之水平距離在二點一公尺以下；但建築物為防火構造者，因牆柱樓板具一定時效、延燒受抑制，該水平距離得增加為二點三公尺以下。餐廳屬前述一般場所，題目又已載明為防火構造，故其二點三公尺之敘述正確，故選 D。\n【逐項排除】\n(A) 錯誤：戲院、舞廳、夜總會、歌廳、集會堂等表演場所之舞臺及道具室，火載量高、延燒迅速，水平距離加嚴為一點七公尺以下，並非二點一公尺。\n(B) 錯誤：依第二百十一條第二款，公共危險物品等場所設置自動撒水設備時，防護對象任一點至撒水頭之水平距離在一點七公尺以下，亦非二點一公尺。\n(C) 錯誤：高架儲存倉庫設於貨架之撒水頭，水平距離固然在二點五公尺以下，但條文要求以交錯方式設置，題目寫成平行方式，錯在設置方式。\n(D) 正確：防火構造建築物之一般反應型撒水頭，得由二點一公尺放寬為二點三公尺。\n【記憶點】公共危險物品場所一律一點七；防火構造加零點二；貨架要交錯、不要平行。","撒水頭水平距離的規定，本質是把「一顆撒水頭能有效撒水的半徑」換算成配置間距。距離愈短，單位面積的撒水頭愈密、放水密度愈高，法規因此用它來對應場所的危險度：火載量高、延燒快的表演場所舞臺及道具室、電影院放映室、易燃物品倉庫加嚴；汽車修理廠、室內停車空間等次之；一般場所則再依撒水頭感度與建築構造分級。快速反應型（第一種感度）因感熱元件反應更快，能在火勢更小的階段放水，故容許的水平距離大於一般反應型；防火構造建築物因牆、柱、樓板具一定時效，火勢成長與延燒範圍受限，也再放寬一段。\n公共危險物品等場所自成一格。依第二百十一條，該類場所之自動撒水設備，防護對象任一點至撒水頭之水平距離在一點七公尺以下；開放式撒水設備每一放水區域樓地板面積在一百五十平方公尺以上；水源容量使用密閉式撒水頭時，應在設置三十個撒水頭繼續放水三十分鐘之水量以上，使用密閉乾式或預動式流水檢知裝置時另追加十個；緊急電源之供電容量應供有效動作四十五分鐘以上；存放易燃性物質處所，撒水頭迴水板下方九十公分及水平方向三十公分以內應保持淨空間。相較於一般場所，危險物品場所在撒水頭密度與放水時間上都明顯加嚴。\n高架儲存倉庫的貨架撒水頭要求交錯設置，是因為貨架呈縱列堆疊，若上下層撒水頭垂直對齊，同一縱列貨物的側面會落在所有撒水頭的撒水陰影裡；交錯排列才能讓上下層的撒水範圍互補，消除死角。命題者最愛的三種改寫，就是把交錯寫成平行、把公共危險物品場所的一點七寫成二點一，以及把防火構造的放寬硬套到非防火構造的場所上，歷屆題中反覆出現，逐一比對危險度分級與構造前提即可拆解。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-107-1-water-chemical-036","有關自動撒水設備末端查驗閥之敘述，下列何者正確？",36,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-107-1-water-chemical-038","依各類場所消防安全設備設置標準之規定，下列何種場所不需設置室外消防栓設備？",38,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-107-1-water-chemical-035","採用移動式放射方式之乾粉滅火設備，藥劑種類為第一種乾粉時，每一具噴射瞄子所需藥劑放射量為：",35,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-107-1-water-chemical-039","為執行檢修申報，針對水霧滅火系統綜合檢查，對於判定方法之敘述，下列何者正確？",39,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-107-1-water-chemical-034","依 NFPA 2001 之規定，潔淨式氣體滅火系統於一般場所之藥劑放射時間（達設計濃度 95%之時間），下列敘述何者正確？",34,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-107-1-water-chemical-040","進行幫浦性能試驗時，幫浦之出水量在額定出水量之 1.5 倍時，其全揚程應為額定出水量在性能曲線上全揚程百分之多少以上？",40,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-037",111,"依規定 112 年度滅火器檢查合格時，應採用那種顏色檢修環？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-water-chemical-037",110,"依消防安全設備及必要檢修項目檢修基準，水道連結型自動撒水設備之末端查驗閥或連結之水龍頭等日常生活用水設施配置的壓力表，其放水壓力應在 X kgf\u002Fcm2 以上 Y kgf\u002Fcm2 以下。X、Y 分別為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-water-chemical-037",109,"連結送水管之配管設置規定，應能承受送水設計壓力 1.5 倍以上之水壓，且能持續多少時間才合格？",{"webId":66,"year":67,"stem":68,"number":13},"fire-108-1-water-chemical-037",108,"進行滅火器之檢查時，有關一般注意事項，下列何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-037",106,"消防幫浦之全閉揚程應為性能曲線上全揚程之百分之多少以下，方符合檢修基準要求？",1785123168134]