[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-108-1-alarm-evacuation-005":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-警報與避難系統消防安全設備概要-005","fire-108-1-alarm-evacuation-005",108,1,5,"瓦斯漏氣火警自動警報設備進行性能檢查，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"同一回路檢知器數量有 11 個，選取檢查數量 2 個","同一回路檢知器數量有 33 個，選取檢查數量 20%以上","檢知器之「加瓦斯試驗器」其瓦斯濃度測試值一般是取該瓦斯燃燒下限之 1\u002F8 值","使用「加瓦斯試驗器」進行瓦斯測試，對空氣比重未滿一者，使用異丁烷進行試驗","B",null,[],false,"本題考點：《消防安全設備及必要檢修項目檢修基準》瓦斯漏氣火警自動警報設備一章之性能檢查，檢知器選取檢查數量表，以及瓦斯比重與試驗氣體之對應關係。\n【正解理由】該章性能檢查對檢知器訂有選取檢查數量表，一回路檢知器一至五個選一個、六至十個選二個、十一至十五個選三個、十六至二十個選四個、二十一至二十五個選五個、二十六至三十個選六個，三十個以上者則改以百分之二十以上選取。同一回路三十三個已逾三十個，應按百分之二十以上抽驗，故選 B。\n【逐項排除】\n(A) 十一個落在十一至十五個之級距，表列應選三個，僅選二個抽驗量不足，不符表列規定。\n(B) 三十三個屬三十個以上，改採比例抽驗百分之二十以上，與表列一致，為本題應選者。\n(C) 該項檢查方法對加瓦斯試驗器所規範者為試驗氣體之選用，其測試值並非取瓦斯燃燒下限之八分之一，敘述與基準所定不符，屬自行加設之比例。\n(D) 基準明定對空氣之比重未滿一者使用甲烷、比重大於一者使用異丁烷，本項恰將兩者對調；輕於空氣者配甲烷、重於空氣者配異丁烷，方向不可顛倒。\n【記憶點】級距表抽到三十個為止，逾三十個改抽兩成；輕瓦斯配甲烷、重瓦斯配異丁烷。","瓦斯漏氣火警自動警報設備的檢查邏輯，是沿著「檢知器—中繼器—受信總機—警報裝置」這條訊號鏈逐段驗證。檢修基準所定之檢查方法，是以加瓦斯試驗器對檢知器加氣，測定其動作及傳至受信總機瓦斯漏氣燈亮燈之時間，並同時確認中斷器、瓦斯漏氣表示燈及檢知區域警報裝置的動作狀況。判定上，所測得之時間扣除介入中繼器之五秒、以及採第三種測定方式時之二十秒後，應在六十秒內；檢知區域警報裝置之音壓應在七十分貝以上，且音色須有別於其他機械噪音，並於檢知區域內任一點均能有效聽到。\n選取檢查數量採級距表而非固定比例，理由在於回路內檢知器數量少時，抽樣比例必須拉高才有代表性；數量多時若仍逐一放大絕對值，檢修負擔將失衡，因此在三十個以上改以百分之二十的比例控制。基準另定兩項注意事項：每次測試應輪流選取，並於圖面或檢查表上註記每次選取之位置，避免每回都抽同幾個；抽驗中若發現不良品，該回路之全部檢知器均應實施檢查，等於把抽樣結果放大為全數普查。\n試驗氣體的分流對應設置端的分流。《各類場所消防安全設備設置標準》第 141 條依瓦斯對空氣之比重分兩套裝設方式：比重未滿一時，檢知器設於距瓦斯燃燒器具或瓦斯導管貫穿牆壁處水平距離八公尺以內，下端裝設在天花板下方三十公分範圍內；比重大於一時，水平距離縮為四公尺以內，且上端裝設在距樓地板面三十公分範圍內。輕於空氣者往上積、重於空氣者往下沉，試驗氣體自然也依此區分。第 140 條界定本設備所稱瓦斯為天然氣、液化石油氣及其他經中央主管機關指定者；第 145 條規定其緊急電源應使用蓄電池設備，容量能使二回路有效動作十分鐘以上、其他回路能監視十分鐘以上；第 22 條則規定設有火警自動警報或瓦斯漏氣火警自動警報設備之建築物，應設置緊急廣播設備，三條可串成一組記憶。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-alarm-evacuation-004","某一防火構造建築物，地上 5 層且為無開口樓層，1 至 2 層供辦公室用途使用，3 至 5 層供餐廳用途使用，各樓層樓地板面積皆為 200 平方公尺，依照各類場所消防安全設備設置標準之規定，請問本場所火警自動警報設備之設置情形，下列何者正確？",4,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-alarm-evacuation-006","探測器應依裝置場所高度選擇探測器種類裝設，下列何者錯誤？",6,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-alarm-evacuation-003","用途為補習班，居室樓地板面積 300 平方公尺，採用有效通風方式檢討，其排煙口設於天花板下方 80 公分內，試問有效通風面積最少須要多少平方公尺以上方可符合規定？",3,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-alarm-evacuation-007","有關無線電通信輔助設備設置規定，下列何者正確？",7,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-alarm-evacuation-002","特別安全梯的安全梯與緊急昇降機兼用時，其排煙機、進風機之排煙量、進風量須在每秒多少立方公尺以上？",2,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-alarm-evacuation-008","感熱式局限型探測器使用加熱試驗器對探測器加熱，依動作時間方法判斷，下列何者符合動作時間之規定？（標稱動作溫度與周圍溫度之差低於 50 度）",8,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-005",110,"避難方向指示燈之認可作業中，其引導燈具不包括下列何種附加功能？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-005",109,"差動式局限型探測器係利用下列何構件，來防止設置場所因正常溫度變化而造成火災誤報？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-005",107,"有一地下三層地上十層之建築物，總樓地板面積 5000 平方公尺，若起火樓層位於三樓時，下列那一樓層火警自動警報設備須鳴動？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-005",106,"依各類場所消防安全設備設置標準規定，下列何種場所如設置高感度密閉式撒水頭自動撒水設備，得免設火警自動警報設備？",1785123171779]