[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-108-1-alarm-evacuation-008":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-警報與避難系統消防安全設備概要-008","fire-108-1-alarm-evacuation-008",108,1,8,"感熱式局限型探測器使用加熱試驗器對探測器加熱，依動作時間方法判斷，下列何者符合動作時間之規定？（標稱動作溫度與周圍溫度之差低於 50 度）",{"A":16,"B":17,"C":18,"D":19},"定溫式局限型 2 種，動作時間 100 秒","定溫式局限型特種，動作時間 50 秒","差動式局限型 2 種，動作時間 40 秒","差動式局限型 1 種，動作時間 40 秒","A",null,[],false,"本題考點：《消防安全設備及必要檢修項目檢修基準》火警自動警報設備一章之性能檢查，感熱式局限型探測器以加熱試驗器加熱之動作時間判定，四個選項須逐一與表列上限比對。\n【正解理由】該章性能檢查所列之動作時間表，對差動式局限型與補償式局限型定為一種、二種均三十秒；定溫式局限型則為特種四十秒、一種六十秒、二種一百二十秒。題示標稱動作溫度與周圍溫度之差低於五十度，故直接以表列時間判定，不予放寬。定溫式局限型二種之判定上限為一百二十秒，實測一百秒未逾上限，符合動作時間之規定，故選 A。判定方式即以實測時間與該種別之表列時間相比，未逾表列時間者為合格。\n【逐項排除】\n(A) 定溫式局限型二種上限一百二十秒，實測一百秒仍在容許時間內，為本題應選者。\n(B) 定溫式局限型特種上限四十秒，實測五十秒已逾表列時間，應判定為不良。\n(C) 差動式局限型二種上限三十秒，實測四十秒逾時，不符規定；靈敏度較高的種別反而給的時間最短。\n(D) 差動式局限型一種上限同為三十秒，實測四十秒同樣逾時。\n【記憶點】差動式一律三十秒；定溫式特種四十、一種六十、二種一百二十，愈鈍的給愈久。","感熱式與偵煙式的動作時間判定各有一張表，命題者最愛互換。感熱式如前所述以三十、四十、六十、一百二十四個數字構成；偵煙式則另定離子式局限型與光電式局限型為一種三十秒、二種六十秒、三種九十秒。設有蓄積性能者，判定時要把蓄積式中繼器或受信總機設定之蓄積時間併計：感熱式合計上限二十秒、偵煙式合計上限六十秒；蓄積型偵煙式探測器還須再加其標稱蓄積時間並多給五秒；火焰式則以三十秒加蓄積時間，合計上限二十秒。基準並要求具蓄積性能之中繼器或受信總機，於操作手動報警機時應與設定之蓄積時間無關而自動火災表示，也就是蓄積性能必須立即解除，避免人為報警仍被拖延。\n這些數字的分配來自探測原理。差動式感測的是溫升速率，火災初期溫度陡升時即刻反應，故不分一種二種都給三十秒；定溫式必須等本體被加熱至標稱動作溫度，熱慣性造成延遲，靈敏度愈低者延遲愈長，因而特種四十秒、一種六十秒、二種一百二十秒逐級放寬。也正因定溫式依賴溫差驅動，當標稱動作溫度與周圍溫度差距拉大時，加熱到動作點所需時間會顯著延長，判定時間才需另行放寬；本題明示差值低於五十度，用意就是要考生直接套表，不要自作主張延長。\n選取檢查數量是同一節的另一常考點。定溫式非再用型因試驗即失效，改按選取檢查數量表抽驗：設置一至十個抽一個、十一至五十個抽二個、五十一至一百個抽四個、一百零一個以上抽七個。蓄積性能檢查則依火警分區數選定，五十以下感熱式、偵煙式、火焰式各選一個，五十一以上各選二個。與設置端第 120 條的有效探測範圍表對照更牢：防火構造建築物裝置面未滿四公尺時，差動式局限型一種九十平方公尺、二種七十平方公尺，定溫式局限型特種七十平方公尺、一種六十平方公尺、二種二十平方公尺；同條並要求探測器下端裝設在裝置面下方三十公分範圍內。從動作時間到有效探測範圍，貫穿的都是「愈鈍者，時間放寬、範圍縮小」這一條線。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-alarm-evacuation-007","有關無線電通信輔助設備設置規定，下列何者正確？",7,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-alarm-evacuation-009","緩降機固定架或支固器具使用錨定螺栓固定時，選用螺紋標稱為 M12×1.75 之螺栓，試問其螺栓埋入混凝土內不含灰漿部分之深度（mm）及轉矩值須為多少（kgf-cm）？",9,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-alarm-evacuation-006","探測器應依裝置場所高度選擇探測器種類裝設，下列何者錯誤？",6,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-alarm-evacuation-010","某一廣播區域面積為 150 平方公尺，設有揚聲器，請問距所設揚聲器 1 m 處所測得之音壓須達多少以上才符合規定？",10,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-alarm-evacuation-005","瓦斯漏氣火警自動警報設備進行性能檢查，下列敘述何者正確？",5,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-alarm-evacuation-011","為提升火災發生時之通報效率，並避免延誤報案致生重大火災事故，各類場所消防安全設備設置標準於 107 年 10 月 17 日增列下列那一種設備種類？",11,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-008",110,"下列何組感知線型或分布型探測器在進行外觀試驗時，均須判定其感熱元件之極性有無誤接？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-008",109,"緊急照明燈在地面之水平面照度，使用低照度測定用光電管照度計測得之值，在地下建築物之地下通道，其地板面應在 X 勒克司（Lux）以上，其他場所應在 Y 勒克司（Lux）以上。其中 X， Y 值為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-008",107,"當差動式分布型探測器為空氣管式時，下列那一項的敘述不符合設置標準？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-008",106,"天花板設排氣口或回風口時，偵煙式探測器應裝置於排氣口或回風口周圍多少距離範圍內？",1785123171800]