[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-108-1-alarm-evacuation-034":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-警報與避難系統消防安全設備概要-034","fire-108-1-alarm-evacuation-034",108,1,34,"依各類場所消防安全設備設置標準之規定，下列何種避難器具的開口面積應為高 60 公分以上，寬 60 公分以上？",{"A":16,"B":17,"C":18,"D":19},"緩降機","避難梯","救助袋","滑臺","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 162 條所附之避難器具開口部必要開口面積對照表，考的是四種避難器具各自對應的開口尺寸。\n【正解理由】依《各類場所消防安全設備設置標準》第 162 條之表，「救助袋」之開口面積為「高六十公分以上，寬六十公分以上」，是全表唯一高、寬同為六十公分的器具；救助袋須讓避難者以坐姿進入袋體再轉為滑降姿勢，開口取高寬對稱的方形才有迴旋餘裕，故選 C。\n【逐項排除】\n(A) 緩降機與避難梯、避難繩索及滑杆同列一格，開口面積為「高八十公分以上，寬五十公分以上或高一百公分以上，寬四十五公分以上」，高度門檻為八十或一百公分、寬度僅需四十五至五十公分，與六十乘六十不符。\n(B) 避難梯與緩降機同格，適用同一組數值，人員係側身跨出開口後沿梯身下降，條文以高度為主要控制值，並非高寬各六十公分。\n(C) 救助袋於表中單獨一列，明定高六十公分以上、寬六十公分以上，與題幹敘述完全相符，為本題應選者。\n(D) 滑臺之開口面積為「高八十公分以上，寬為滑臺最大寬度以上」，寬度不是固定數字，而是隨滑臺本體寬度浮動，不會是六十公分。\n【記憶點】救助袋六六成雙（60×60），緩降機一組是八十配五十或一百配四十五，滑臺與避難橋的寬度一律跟著器具本體走。","《各類場所消防安全設備設置標準》第 162 條以一張對照表統一規範避難器具的開口部，共分四列：第一列把緩降機、避難梯、避難繩索及滑杆合併，開口面積為「高八十公分以上，寬五十公分以上或高一百公分以上，寬四十五公分以上」，給了兩組可擇一的組合；第二列救助袋為「高六十公分以上，寬六十公分以上」；第三列滑臺為「高八十公分以上，寬為滑臺最大寬度以上」；第四列避難橋為「高一百八十公分以上，寬為避難橋最大寬度以上」。四列並排即可看出立法邏輯：器具本體自帶固定寬度者（滑臺、避難橋），開口寬度直接跟著器具走；器具屬袋體、梯身、繩索這類柔性或線性構件者，才用絕對數字管制。\n避難橋的高度要求為何高達一百八十公分？因為避難橋是在建築物之間架橋讓人走過去，通過姿勢是站立，開口必須容納成年人的身高；救助袋是把人包進袋內滑降，入袋時多為坐姿再轉為仰躺，高與寬都需要餘裕，所以取六十乘六十的方形；緩降機與避難梯則是身體縱向側身跨越開口，高度需求大而寬度可以壓縮，條文才會出現「高一百公分、寬四十五公分」這種瘦長組合。理解使用姿勢，四組數值就不必硬背。\n分類上也要一併釐清。同標準第 10 條將避難逃生設備分為三類：標示設備（出口標示燈、避難方向指示燈、觀眾席引導燈、避難指標）、避難器具（滑臺、避難梯、避難橋、救助袋、緩降機、避難繩索、滑杆及其他避難器具）與緊急照明設備。本題四個選項全部落在避難器具這一類，考的不是分類而是尺寸，作答時不要被選項的類別一致性帶偏。\n此類命題常見兩種變化型：一是倒過來問「開口面積為高八十公分以上、寬五十公分以上者為下列何種器具」，二是把避難橋的一百八十公分改成一百五十公分當誘答。應試時先判斷該器具是「走過去、滑下去，還是垂降下去」，再回到表格取值，可穩定得分。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-alarm-evacuation-033","有關 B 級出口標示燈（顯示避難方向符號者）及 B 級避難方向指示燈有效範圍的規定，下列何者正確？",33,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-alarm-evacuation-035","依各類場所消防安全設備設置標準規定，在應設排煙設備之場所，有關其排煙設備設置之描述，下列何者錯誤？",35,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-alarm-evacuation-032","下列出口標示燈及避難方向指示燈之緊急電源描述何者正確？",32,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-alarm-evacuation-036","依各類場所消防安全設備設置標準第 28 條應設置排煙設備之規定，下列何者錯誤？",36,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-alarm-evacuation-031","依各類場所消防安全設備設置標準對於出口標示燈設置之相關規定，下列何者正確？",31,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-alarm-evacuation-037","某機場候機室樓地板面積 300 m2，自然排煙設備其窗戶都在天花板或其下方 80 公分範圍內，共有 10 扇窗，採正向由上往外推可達 90°，請問每一扇窗面積多大才合格？",37,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-034",110,"依消防安全設備及必要檢修項目檢修基準，救助袋進行開口部外觀檢查時，開口部面積之限制，下列何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-alarm-evacuation-034",109,"有關排煙設備綜合檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-034",107,"依各類場所消防安全設備檢修及申報作業基準規定，緊急照明設備在建築物總樓地板面積為 5000 平方公尺時，檢查緊急電源容量能否持續 30 分鐘之檢查數量應在多少個以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-034",106,"在裝設定溫式感知線型探測器場所，進行回路合成阻抗試驗時，會使用下列何種檢查儀器？",1785123172078]