[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-fire-law-027":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-消防法規概要-027","fire-108-1-fire-law-027",108,1,27,"下列有關二氧化碳滅火設備各種標示規格規定之敘述，何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"手動啟動裝置標示規格，尺寸 A：300 mm 以上，紅底白字","手動啟動裝置標示規格，尺寸 B：80 mm 以上，紅底白字","放射表示燈規格，尺寸 A：280 mm 以上，點燈時白底紅字","放射表示燈規格，尺寸 B：80 mm 以上，燈具本體為紅色","B",null,[],false,"本題考點：二氧化碳滅火設備「手動啟動裝置標示」與「放射表示燈」兩組標示規格的尺寸與底色字色。\n【正解理由】《各類場所消防安全設備設置標準》對二氧化碳滅火設備之各種標示規格，採「由中央主管機關另定」之授權體例，實際尺寸與配色以內政部公告之二氧化碳滅火設備各種標示規格圖說為準。該圖說將手動啟動裝置標示與放射表示燈分列兩組，手動啟動裝置標示之尺寸下限高於放射表示燈（尺寸Ａ為 300 mm 對 280 mm）；(B) 把屬於放射表示燈的尺寸Ｂ 80 mm 移植到手動啟動裝置標示，與規格所定不符，故選 B。\n【逐項排除】\n(A) 手動啟動裝置標示尺寸Ａ 300 mm 以上、紅底白字，與規格圖說一致，敘述正確。\n(B) 紅底白字部分無誤，錯在尺寸Ｂ：80 mm 是放射表示燈的數值，手動啟動裝置標示之尺寸Ｂ下限大於此值，為本題應選者。\n(C) 放射表示燈尺寸Ａ 280 mm 以上，且點燈時為白底紅字，敘述正確。\n(D) 放射表示燈尺寸Ｂ 80 mm 以上，燈具本體為紅色，敘述正確。\n【記憶點】手動啟動裝置紅底白字、放射表示燈白底紅字；尺寸「手大於射」（Ａ：300 對 280），80 mm 只屬放射表示燈。","一、授權體例：設置標準對滅火藥劑量、放射時間等多直接於條文中訂出數值，唯獨「各種標示規格」採授權中央主管機關另定的方式，由內政部以規格圖說公告尺寸Ａ、尺寸Ｂ與配色。命題者考的正是這種「條文不寫數值、數值在公告圖說」的兩層結構。\n二、跨設備準用：《各類場所消防安全設備設置標準》第 98 條明定，乾粉滅火設備之放射方式、選擇閥、啟動裝置、音響警報裝置、安全裝置、緊急電源及各種標示規格，準用二氧化碳滅火設備之規定；同一套標示尺寸與配色在乾粉滅火設備一併適用，是同一考點的常見變化題。\n三、配色的記憶邏輯：手動啟動裝置是「要人主動去操作」的位置標示，採紅底白字，以紅色底吸引注意；放射表示燈則是「藥劑已放射、區域內不得進入」的狀態顯示，點燈時呈白底紅字，燈具本體為紅色。一個是操作點、一個是狀態燈，底色與字色恰好對調，最易互換而失分。\n四、延伸到檢修面：《消防安全設備及必要檢修項目檢修基準》就移動式二氧化碳滅火設備之「標示燈及標示」，其判定方法為標示燈應無變形、損傷等情形且正常亮燈，標示應無損傷、脫落、污損等情形，並標明「移動式二氧化碳滅火設備」字樣。設置階段管尺寸與配色、檢修階段管有無變形污損與能否亮燈，兩階段常合併命題。\n五、作答結構：圖說對每一種標示分別列出尺寸Ａ與尺寸Ｂ兩個下限值，故此類「何者錯誤」題的四個選項必然兩兩成對——(A)(B) 同屬手動啟動裝置標示、(C)(D) 同屬放射表示燈。先分組再逐組比對尺寸與配色，錯置的那一格會立刻浮現，比硬背四組數字可靠。\n六、數值取用：標示規格圖說歷經公告版本更迭，各組尺寸應以該場考試當時內政部公告之版本為準；上開檢修基準線上可得之最早版本為 109 年 8 月 21 日，晚於本場 108 年 6 月 2 日之考試，僅供理解該項檢查之體例與判定方式。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-fire-law-026","依防火牆及防火水幕設置基準規定，若防火水幕之防護高度為 12 公尺，請問其每公尺水幕長度放水量應在每分鐘多少公升以上？",26,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-fire-law-028","依可燃性高壓氣體儲存場所防爆牆設置基準規定，防爆牆分為鋼筋混凝土製、混凝土空心磚製及鋼板製等三種，並應設置於堅固基礎上，其強度應能承受可能預料之氣體爆炸衝擊。下列有關其構造規定何者錯誤？",28,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-fire-law-025","依防火牆及防火水幕設置基準規定，假想火面高度為將儲槽水平剖面最大直徑乘以規定之數值。當公共危險物品之閃火點未達攝氏 70 度時，應乘以之數值為何？",25,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-fire-law-029","依各類場所消防安全設備設置標準，下列有關室內消防栓箱的規定何者錯誤？",29,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-fire-law-024","依消防法第 6 條及其相關規定，有關住宅用火災警報器下列何者正確？",24,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-fire-law-030","依各類場所消防安全設備設置標準規定，下列何種處所得免設排煙設備？",30,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-027",111,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，儲存第五類公共危險物品分級屬 A 型，其儲存量達管制量 5 倍以上未達 10 倍者且周圍設有圍牆之室內儲存場所，其應保留空地寬度應為多少公尺以上？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-fire-law-027",110,"依各類場所消防安全設備設置標準規定，自動撒水設備得依實際情況需要選擇適當型式設置。但下列何種場所應設開放式？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-fire-law-027",109,"有一 500 平方公尺地下停車場，採水霧滅火設備，依各類場所消防安全設備設置標準，其水源容量應保持多少立方公尺以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-fire-law-027",107,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，製造、儲存或處理六類物品達管制量多少倍以上之場所，應由管理權人選任管理或監督層次以上之幹部為保安監督人，擬訂消防防災計畫，報請當地消防機關核定，並依該計畫執行六類物品保安監督相關業務？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-027",106,"下列有關防火牆及防火水幕設置基準規定之敘述，何者錯誤？",1785123159140]