[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-water-chemical-012":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-水與化學系統消防安全設備概要-012","fire-108-1-water-chemical-012",108,1,12,"主成分為碳酸氫鉀及尿素化合物之乾粉滅火藥劑，採全區放射方式時，每立方公尺防護區域所需滅火藥劑量為多少公斤？",{"A":16,"B":17,"C":18,"D":19},"0.24","0.36","0.6","1.8","A",null,[],false,"本題考點：乾粉滅火設備全區放射方式，第四種乾粉（主成分碳酸氫鉀及尿素化合物）每立方公尺防護區域所需之滅火藥劑量。\n【正解理由】依《各類場所消防安全設備設置標準》第 99 條第一款所附表格，全區放射方式每立方公尺防護區域所需滅火藥劑量，第一種乾粉為零點六公斤、第二種乾粉為零點三六公斤、第三種乾粉為零點三六公斤、第四種乾粉為零點二四公斤。題目主成分為碳酸氫鉀及尿素化合物者即第四種乾粉，故選 A。\n【逐項排除】\n(A) 零點二四公斤為表列第四種乾粉之值，其滅火效能最高，單位體積所需藥劑量因而最少，敘述正確。\n(B) 零點三六公斤是第二種乾粉（碳酸氫鉀）與第三種乾粉（磷酸二氫銨）的表列值，與第四種混淆。\n(C) 零點六公斤為第一種乾粉（碳酸氫鈉）之表列值，是四種乾粉中單位體積用量最大者。\n(D) 一點八公斤並非全區放射的單位體積用量，而是第四種乾粉每平方公尺開口部所需追加之滅火藥劑量。\n【記憶點】全區體積用量「零點六、零點三六、零點三六、零點二四」，開口部追加量恰為其七點五倍。","四種乾粉的成分與效能：第一種乾粉主成分為碳酸氫鈉，第二種為碳酸氫鉀，第三種為磷酸二氫銨，第四種為碳酸氫鉀及尿素化合物。乾粉滅火機制以負觸媒（化學抑制）作用為主，粉粒受熱分解釋出鹼金屬成分，捕捉燃燒連鎖反應中的自由基。鉀的捕捉效率高於鈉，第四種乾粉因碳酸氫鉀與尿素之化合物在火焰中會爆裂增生表面積，效能再往上提，因此第 99 條表列單位體積藥劑量由零點六依序降到零點二四，約僅為第一種的四成。\n開口部追加量的比例規律：第 99 條同一表格中，每平方公尺開口部所需追加滅火藥劑量分別為四點五、二點七、二點七、一點八公斤，恰為各該單位體積藥劑量的七點五倍。理由是未設自動關閉裝置的開口會持續洩漏藥劑，必須以開口面積為基礎另行加算。記住「七點五倍」這個比例，只要背得出零點六、零點三六、零點二四，就能推出四點五、二點七、一點八。\n放射時間與噴頭：第 100 條規定全區放射方式所設之噴頭能使放射藥劑迅速均勻地擴散至整個防護區域；乾粉噴頭之放射壓力在每平方公分一公斤以上或 0.1MPa 以上；依第 99 條第一款或第二款所核算之滅火藥劑量須於三十秒內全部放射完畢；局部放射方式所設噴頭之有效射程內應涵蓋防護對象所有表面，且所設位置不得因藥劑之放射使可燃物有飛散之虞。\n全區與局部的對照：第 99 條第二款局部放射方式改以防護對象每平方公尺表面積核算，第一種乾粉八點八公斤、第二種或第三種乾粉五點二公斤、第四種乾粉三點六公斤，追加倍數均為一點一。全區看體積、局部看表面積，是乾粉題最基本的分流判斷，看到題目給「防護區域體積」或「防護對象表面積」就能立刻定位該用哪一組數字。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-water-chemical-011","二氧化碳滅火設備使用氣體啟動者，啟動用氣體容器之內容積應有 1 公升以上，其所儲存之二氧化碳重量在 0.6 公斤以上，且其充填比應在多少以上？",11,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-water-chemical-013","依各類場所消防安全設備設置標準之規定，乾粉滅火設備配管及閥類，下列設置規定何者錯誤？",13,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-water-chemical-010","有一電信機械室，設置二氧化碳滅火設備，採全區放射方式，其所核算之滅火藥劑量應於多少秒內全部放射完畢？",10,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-water-chemical-014","依各類場所消防安全設備設置標準之規定，加壓式乾粉滅火設備應設壓力調整裝置，可調整壓力至若干 MPa 以下？",14,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-water-chemical-009","有一總機室，設置二氧化碳滅火設備，採全區放射方式，其每立方公尺防護區域所需滅火藥劑量為多少公斤？",9,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-water-chemical-015","依各類場所消防安全設備檢修及申報作業基準，對蓄壓式二氧化碳滅火器及海龍滅火器進行重量檢查時，如失重超過多少%以上或壓力表示值在綠色範圍外時，應予以更新？",15,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-012",111,"有關水霧滅火設備，依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-water-chemical-012",110,"進行乾粉滅火設備性能檢查時，對於滅火藥劑檢查注意事項，溫度及濕度超過多少以上時，應暫停檢查？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-water-chemical-012",109,"消防水系統設置呼水裝置時，其溢水用排水管口徑應在多少尺寸以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-012",107,"設置乾粉滅火設備時，全區及局部放射之緊急電源應為自用發電設備或蓄電池設備，其容量應能使設備有效動作多久以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-012",106,"簡易自動滅火設備進行性能檢查時，其蓄壓式滅火藥劑量應與標示重量差異在何範圍以內？",1785123167439]