[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-water-chemical-014":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-水與化學系統消防安全設備概要-014","fire-108-1-water-chemical-014",108,1,14,"依各類場所消防安全設備設置標準之規定，加壓式乾粉滅火設備應設壓力調整裝置，可調整壓力至若干 MPa 以下？",{"A":16,"B":17,"C":18,"D":19},"1.5","2","2.5","3","C",null,[],false,"本題考點：加壓式乾粉滅火設備壓力調整裝置的法定調整上限，以及 kgf\u002Fcm² 與 MPa 的併列寫法。\n【正解理由】依《各類場所消防安全設備設置標準》第 107 條：「加壓式乾粉滅火設備應設壓力調整裝置，可調整壓力至每平方公分二十五公斤以下或 2.5MPa 以下。」條文以每平方公分二十五公斤與 2.5MPa 兩種單位併列同一門檻，題目既以 MPa 提問，對應值即為 2.5，故選 C。\n【逐項排除】\n(A) 1.5 相當於每平方公分十五公斤，第 107 條並無此數值；「一點五」在乾粉設備出現於第 105 條銅管耐壓的倍數規定，是倍數而非壓力值，兩者不可混用。\n(B) 2 相當於每平方公分二十公斤，低於條文所定之調整上限，第 107 條未以此為門檻。\n(C) 2.5 與條文「每平方公分二十五公斤以下或 2.5MPa 以下」相符，即加壓用氣體經調整後送入儲存容器的壓力上限，為本題正解。\n(D) 3 相當於每平方公分三十公斤，已超出條文所定上限；調整壓力若逾越法定值，乾粉在配管內的流動狀態即偏離設計條件。\n【記憶點】加壓式乾粉「調到二十五公斤等於 2.5MPa」，壓力到位後由定壓動作裝置接手開啟放出閥。","乾粉滅火設備依加壓方式分為加壓式與蓄壓式，兩者的附屬裝置規定不同，是同一組條文的核心比較。加壓式以另設的加壓用氣體容器在動作時將乾粉推出，氣體壓力遠高於儲存容器與配管的使用壓力，因此《各類場所消防安全設備設置標準》第 107 條要求設壓力調整裝置，把壓力調整至每平方公分二十五公斤以下或 2.5MPa 以下再送入儲存容器。第 108 條接著規定定壓動作裝置：啟動裝置動作後，儲存容器壓力達設定壓力時，應使放出閥開啟，且定壓動作裝置設於各儲存容器——先加壓到位、再開閥放出，乾粉才能與氣體充分混合而順利流動，避免壓力不足使粉體在配管內淤積。蓄壓式則平時即以氣體與乾粉共同蓄壓於容器內，故第 109 條要求設置以綠色表示使用壓力範圍之指示壓力表，由指針是否落在綠色範圍判斷是否仍具放射能力。\n單位換算方面，法規採 1MPa 對應每平方公分十公斤的整數折算，故二十五公斤即 2.5MPa、四十二公斤即 4.2MPa、一百六十五公斤即 16.5MPa。考場上看到 kgf\u002Fcm² 與 MPa 併列，直接移動小數點一位即可，不必用物理上 9.807 的精確換算值。\n數值對照可整理成三組：加壓式壓力調整上限 2.5MPa；蓄壓式壓力若落在每平方公分二十五公斤（2.5MPa）以上、四十二公斤（4.2MPa）以下，配管須升級為 CNS 四六二六無縫鋼管管號 Sch 40 以上厚度（第 105 條第一款第二目）；銅管耐壓為調整壓力或最高使用壓力的一點五倍以上。三個數值分屬不同對象，不可互換。\n檢修面向也有對應項目：《消防安全設備及必要檢修項目檢修基準》第一章滅火器的性能檢查列有壓力調整器一項，其判定方法為壓力指針之動作應正常、調整壓力值應在綠色範圍內，指針無法正常動作或調整壓力值在綠色範圍外者，應予修復或更換，體例與設置端「應設壓力調整裝置」的要求相互呼應。相關考點還會延伸到第 105 條第二款第三目，放出閥及加壓用氣體容器閥之手動操作部分設於火災時易於接近且安全之處。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-water-chemical-013","依各類場所消防安全設備設置標準之規定，乾粉滅火設備配管及閥類，下列設置規定何者錯誤？",13,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-water-chemical-015","依各類場所消防安全設備檢修及申報作業基準，對蓄壓式二氧化碳滅火器及海龍滅火器進行重量檢查時，如失重超過多少%以上或壓力表示值在綠色範圍外時，應予以更新？",15,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-water-chemical-012","主成分為碳酸氫鉀及尿素化合物之乾粉滅火藥劑，採全區放射方式時，每立方公尺防護區域所需滅火藥劑量為多少公斤？",12,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-water-chemical-016","依各類場所消防安全設備檢修及申報作業基準，公共危險物品等場所達顯著滅火困難者設置之第一種滅火設備之室內消防栓，其放水壓力應在 X kgf\u002Fcm2 以上 Y kgf\u002Fcm2 以下。則 X+Y 為若干？",16,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-water-chemical-011","二氧化碳滅火設備使用氣體啟動者，啟動用氣體容器之內容積應有 1 公升以上，其所儲存之二氧化碳重量在 0.6 公斤以上，且其充填比應在多少以上？",11,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-water-chemical-017","依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備之第一種消防栓水帶及瞄子檢查方法，製造年份超過 10 年或無法辨識製造年份之水帶，應將消防水帶兩端之快速接頭連接於耐水壓試驗機，施以 X kgf\u002Fcm2 以上水壓試驗 Y 分鐘合格，始得繼續使用。則 X+Y 為若干？",17,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-014",111,"開放式自動撒水設備之自動啟動裝置，感知撒水頭應設在裝置面距樓地板面高度多少公尺以下，且能有效探測火災處？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-water-chemical-014",110,"高壓電器設備其電壓在 7000 伏特以下時，水霧噴頭及配管與高壓電器設備應保持多少公分之標準離開距離？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-water-chemical-014",109,"測量室內消防栓瞄子直線放水之壓力時，應將壓力表之進水口，放置於瞄子前端多少距離處，讀取壓力表的指示值？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-014",107,"二氧化碳滅火系統採全區放射方式高壓式系統，共設有 24 瓶儲存容器，進行綜合檢查時，放射試驗所需之藥劑量，應為下列何者？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-014",106,"達顯著滅火困難之公共危險物品室外儲存場所，設置室外消防栓設備，其緊急電源應使用發電機設備或蓄電池設備，供電容量應供其有效動作至少多久以上？",1785123167466]