[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-water-chemical-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-水與化學系統消防安全設備概要-025","fire-108-1-water-chemical-025",108,1,25,"下列何者不屬於各類場所消防安全設備設置標準第 8 條所規定的滅火設備？",{"A":16,"B":17,"C":18,"D":19},"滅火器","消防砂","簡易自動滅火設備","海龍滅火設備","D",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 8 條「滅火設備種類」的九款法定列舉。\n【正解理由】第 8 條明定滅火設備種類如下：一、滅火器、消防砂；二、室內消防栓設備；三、室外消防栓設備；四、自動撒水設備；五、水霧滅火設備；六、泡沫滅火設備；七、二氧化碳滅火設備；八、乾粉滅火設備；九、簡易自動滅火設備。全條僅此九款，海龍滅火設備並未列入，故選 D。\n【逐項排除】\n(A) 滅火器列於第 8 條第一款前段，是九款之首，屬法定滅火設備，與本題要找的「不屬於」不符。\n(B) 消防砂與滅火器同列第一款，雖然形式最原始，法律上仍明文列為滅火設備種類之一，並非「其他經認定之設備」。\n(C) 簡易自動滅火設備為第 8 條第九款，其設置規定另見第 111-1 條（排油煙管之感知元件與噴頭配置），確為法定種類。\n(D) 九款列舉中沒有海龍滅火設備，該設備使用之鹵化烷藥劑因破壞臭氧層而受國際管制，未被納入本條種類，為本題應選者。\n【記憶點】第 8 條九款背成「器砂、內外撒、霧沫、碳粉、簡易」，沒有海龍。","第 7 條與第 8 條是設置標準最前面的兩張分類地圖，也是最常被混考的一組。第 7 條把各類場所消防安全設備分成五大類：滅火設備、警報設備、避難逃生設備、消防搶救上之必要設備，以及其他經中央主管機關認定之消防安全設備；第 8 條再把第一大類的滅火設備細分為九款。作答時先確認題目問的是「五大類」還是「九種滅火設備」，答錯層級是最冤枉的失分。\n第 8 條九款的排列有邏輯可循：先是最基本的滅火器與消防砂（同列第一款），接著是以水為主的三組——室內消防栓、室外消防栓、自動撒水，再來是水霧、泡沫這類經水改良的藥劑，然後是氣體與粉體的二氧化碳、乾粉，最後才是第九款簡易自動滅火設備。要特別留意消防砂在法律上確實是滅火設備，而且與滅火器同列一款，不是附帶物品。\n第九款的簡易自動滅火設備考頻不低，設置規定在第 111-1 條：視排油煙管之斷面積、警戒長度及風速配置感知元件及噴頭；排油煙管內風速超過每秒五公尺者，應在警戒長度外側設置放出藥劑之啟動裝置及連動閉鎖閘門，但不設置閘門能有效滅火者不在此限；噴頭有效射程應涵蓋煙罩及排油煙管，且所設位置不得因藥劑放射使可燃物有飛散之虞；防護範圍內之噴頭應一齊放射；儲存鋼瓶及加壓氣體鋼瓶設於攝氏四十度以下之位置。同條第二項並定義警戒長度指煙罩與排油煙管接合處往內五公尺，這一句常單獨被抽出來考。\n易混淆對照：連結送水管（第 26 條）、緊急電源插座（第 29 條）、無線電通信輔助設備（第 30 條）都屬第 7 條第四款消防搶救上之必要設備，不是滅火設備；排煙設備（第 28 條）則歸避難逃生設備。分類題的解法是先把設備歸到五大類，再往下對九款。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-water-chemical-024","某一 15 樓層之建築物，其消防安全設備同時設有第一種室內消防栓及自動撒水設備，其屋頂水箱容量至少應為下列何者？",24,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-water-chemical-026","依各類場所消防安全設備設置標準之規定，建築物高度超過 60 公尺者，連結送水管應採用濕式，其中繼幫浦設置規定之敘述何者錯誤？",26,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-water-chemical-023","依各類場所消防安全設備設置標準之規定，有關應設置室外消防栓設備之場所，下列敘述何者正確？",23,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-water-chemical-027","依各類場所消防安全設備設置標準之規定，室外消防栓於其 I 公尺範圍內附設水帶箱，在 J 公尺以內，保持空曠，不得堆放物品或種植花木。下列 I，J 何者正確？",27,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-water-chemical-022","有關潔淨藥劑氣體滅火設備滅火藥劑主要成分之敘述，下列何者正確？",22,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-water-chemical-028","依法令規定在應設水霧、泡沫、乾粉、二氧化碳滅火設備之場所，但外牆開口面積（常時開放部分）達該層樓地板面積百分之多少以上者，上列滅火設備得採移動式設置？",28,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-025",111,"泡沫試料淨重為 200 g，還原數值如下，則 25%還原時間為何？時間（分） 0 0.5 1 1.5 2 2.5 3 還原量（ml） 0 10 20 30 40 50 60",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-water-chemical-025",110,"自動撒水設備之水源容量規定，若使用側壁型或小區劃型撒水頭時，十層以下樓層在 X 個撒水頭、十一層以上樓層在 Y 個撒水頭繼續放水 20 分鐘之水量以上。X、Y 分別為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-water-chemical-025",109,"高架倉庫內所設置之撒水頭，其放水量每分鐘應在多少公升以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-025",107,"泡沫滅火設備進行綜合檢查時，有關泡沫滅火藥劑 25%還原時間標準值敘述，下列何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-025",106,"某一防護對象物長寬高分別為 5 公尺、4 公尺及 1 公尺，若以高發泡局部放射泡沫滅火系統進行防護，依各類場所消防安全設備設置標準之規定，其防護面積應為多少平方公尺？",1785123167576]