[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-water-chemical-027":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-水與化學系統消防安全設備概要-027","fire-108-1-water-chemical-027",108,1,27,"依各類場所消防安全設備設置標準之規定，室外消防栓於其 I 公尺範圍內附設水帶箱，在 J 公尺以內，保持空曠，不得堆放物品或種植花木。下列 I，J 何者正確？",{"A":16,"B":17,"C":18,"D":19},"I＝3，J＝5","I＝4，J＝4","I＝5，J＝3","I＝5，J＝5","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 40 條室外消防栓的水帶箱附設範圍與周邊空曠距離。\n【正解理由】第 40 條第四款明定室外消防栓應「於其五公尺範圍內附設水帶箱」，第五款則規定「室外消防栓三公尺以內，保持空曠，不得堆放物品或種植花木，並在其附近明顯易見處，標明消防栓字樣」。題目的 I 對應水帶箱附設範圍＝5 公尺，J 對應保持空曠範圍＝3 公尺，故選 C。\n【逐項排除】\n(A) I＝3、J＝5 恰好把兩個數值對調：3 公尺是保持空曠的範圍，5 公尺是水帶箱的附設範圍，方向剛好相反。\n(B) I＝4、J＝4 兩個數值在第 40 條均無所本；該條與四公尺有關的只有第一款「與建築物一樓外牆各部分之水平距離在四十公尺以下」。\n(C) 水帶箱五公尺、空曠三公尺，與第 40 條第四款、第五款逐字相符，為本題應選者。\n(D) I＝5 正確，但 J＝5 錯誤——保持空曠、不得堆放物品或種植花木的範圍是三公尺以內，不是五公尺。\n【記憶點】室外消防栓「水帶箱五公尺內、空地三公尺內」，五在外、三在內。","第 40 條把室外消防栓從管口到周邊環境一次規定完畢，值得整條背下來：口徑在六十三毫米以上，與建築物一樓外牆各部分之水平距離在四十公尺以下；瞄子出水壓力在每平方公分二點五公斤以上或 0.25 MPa 以上，出水量在每分鐘三百五十公升以上；開關位置不得高於地面一點五公尺，並不得低於地面零點六公尺，設於地面下者其水帶接頭位置不得低於地面零點三公尺；於其五公尺範圍內附設水帶箱；三公尺以內保持空曠。五公尺與三公尺之所以一大一小，是因為水帶箱只要人取得到即可，而空曠範圍要確保開關操作與水帶展開不被雜物阻擋，兩者管制的目的不同。\n水帶箱本身也有細部規定：箱體須有足夠裝置水帶及瞄子之深度，箱底二側設排水孔，箱面表面積在零點八平方公尺以上；箱面有明顯而不易脫落之水帶箱字樣，每字在二十平方公分以上；箱內配置口徑六十三毫米及長二十公尺水帶二條、口徑十九毫米以上直線噴霧兩用型瞄子一具及消防栓閥型開關一把。這一款是典型的「數字密集題庫」，六十三、二十、十九、二、一這幾個數字常被抽換其中一個當錯誤選項。\n易混淆對照：室外消防栓的瞄子出水壓力 2.5 kgf\u002Fcm²、出水量 350 L\u002Fmin，與室內消防栓完全不同層級——依第 37 條，消防幫浦出水量第一種室內消防栓每支每分鐘一百五十公升以上、第二種每支每分鐘九十公升以上，全部消防栓數量超過二支時以二支計算；同條並要求室內消防栓瞄子放水壓力超過每平方公分七公斤時應採取有效之減壓措施。記法是室外口徑大、壓力高、水量多，因為它要在戶外遠距離射水；室內則以易操作、不傷人為前提而設有壓力上限。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-water-chemical-026","依各類場所消防安全設備設置標準之規定，建築物高度超過 60 公尺者，連結送水管應採用濕式，其中繼幫浦設置規定之敘述何者錯誤？",26,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-water-chemical-028","依法令規定在應設水霧、泡沫、乾粉、二氧化碳滅火設備之場所，但外牆開口面積（常時開放部分）達該層樓地板面積百分之多少以上者，上列滅火設備得採移動式設置？",28,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-water-chemical-025","下列何者不屬於各類場所消防安全設備設置標準第 8 條所規定的滅火設備？",25,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-water-chemical-029","有一室內停車空間，其防護區為 25 m × 16 m × 4 m，未設自動關閉裝置之開口部面積為 10 m2，擬設置全區放射式乾粉滅火設備，試問所需法定滅火藥劑量最少為多少公斤？",29,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-water-chemical-024","某一 15 樓層之建築物，其消防安全設備同時設有第一種室內消防栓及自動撒水設備，其屋頂水箱容量至少應為下列何者？",24,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-water-chemical-030","依滅火器設置規定，下列何者錯誤？",30,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-027",111,"自動撒水採用密閉乾式或預動式自動撒水設備，撒水頭動作後，流水檢知裝置應在幾分鐘內，使撒水頭放水？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-water-chemical-027",110,"二氧化碳滅火設備之全區放射或局部放射方式防護區域，對放射之滅火藥劑之排放規定，下列何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-water-chemical-027",109,"中央消防主管機關認定儲存大量可燃物之場所天花板高度超過 6 公尺，或其他場所天花板高度超過 10 公尺者，應採用何種撒水頭？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-027",107,"有關二氧化碳滅火設備放射時間之敘述，下列何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-027",106,"依各類場所消防安全設備設置標準，連結送水管之出水口設置，下列敘述何者錯誤？",1785123167593]