[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-108-1-water-chemical-030":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-108-1-水與化學系統消防安全設備概要-030","fire-108-1-water-chemical-030",108,1,30,"依滅火器設置規定，下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"電影片映演場所放映室及電氣設備使用之處所，每 200 平方公尺（含未滿）另設一滅火器","設有滅火器之樓層，自樓面居室任一點至滅火器之步行距離在 20 公尺以下","固定放置於取用方便之明顯處所，並設有長邊 24 公分以上，短邊 8 公分以上，以紅底白字標明滅火器字樣之標識","懸掛於牆上或放置滅火器箱中之滅火器，其上端與樓地板面之距離，18 公斤以上者在 1 公尺以下，未滿 18 公斤者在 1.5 公尺以下","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 31 條滅火器設置規定的各項數值。\n【正解理由】第 31 條第二款明定「電影片映演場所放映室及電氣設備使用之處所，每一百平方公尺（含未滿）另設一滅火器」。選項寫成每 200 平方公尺另設一具，把條文的一百誤植為二百，是四者中唯一與條文牴觸者；題目要找錯誤敘述，故選 A。\n【逐項排除】\n(A) 放映室及電氣設備使用之處所是每一百平方公尺（含未滿）另設一滅火器，不是每二百平方公尺，為本題應選之錯誤敘述。\n(B) 與第三款「設有滅火器之樓層，自樓面居室任一點至滅火器之步行距離在二十公尺以下」相符，敘述正確。\n(C) 與第四款「設有長邊二十四公分以上，短邊八公分以上，以紅底白字標明滅火器字樣之標識」相符，敘述正確。\n(D) 與第五款「其上端與樓地板面之距離，十八公斤以上者在一公尺以下，未滿十八公斤者在一點五公尺以下」相符，敘述正確。\n【記憶點】放映室與電氣處所「每一百平方公尺另設一具」，二百是乙丙丁類核算效能值用的。","第 31 條第一款是核算最低滅火效能值的規定，也是本題誘答的來源：供第 12 條第一款及第五款使用之場所，各層樓地板面積每一百平方公尺（含未滿）有一滅火效能值；供第二款至第四款使用之場所，各層樓地板面積每二百平方公尺（含未滿）有一滅火效能值；鍋爐房、廚房等大量使用火源之處所，以樓地板面積每二十五平方公尺（含未滿）有一滅火效能值。這裡的「二百平方公尺」是乙、丙、丁類場所核算效能值用的分母，與第二款放映室、電氣設備處所「每一百平方公尺另設一具滅火器」是兩件不同的事：前者算的是效能值，後者算的是具數。命題者把二百搬到第二款，正是利用這個相鄰條款的干擾。\n第 31 條可整理成一條記憶線：一算（效能值 100／200／25）、二加（放映室與電氣處所每 100 m² 另設一具）、三步行（20 公尺以下）、四標識（長邊 24 公分、短邊 8 公分、紅底白字）、五高度（18 公斤以上者 1 公尺以下、未滿 18 公斤者 1.5 公尺以下）。款次順序與內容順序一致，背起來不易錯位。\n易混淆對照：第 204 條與第 228 條同樣在講電氣處所與滅火器具數，但那是第四編公共危險物品等場所的規定，只適用公共危險物品或可燃性高壓氣體場所——第 204 條規定電氣設備使用之處所每一百平方公尺（含未滿）應設置第五種滅火設備一具以上；第 228 條則針對可燃性高壓氣體場所、加氣站與儲槽，規定製造、儲存或處理場所設置二具，樓地板面積二百平方公尺以上者每五十平方公尺（含未滿）增設一具，且儲存場所任一點至滅火器之步行距離在十五公尺以下。一般場所走第 31 條的二十公尺，公共危險物品場所另有十五公尺的規定，兩編數值不同，不得互套。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-108-1-water-chemical-029","有一室內停車空間，其防護區為 25 m × 16 m × 4 m，未設自動關閉裝置之開口部面積為 10 m2，擬設置全區放射式乾粉滅火設備，試問所需法定滅火藥劑量最少為多少公斤？",29,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-108-1-water-chemical-031","第四種乾粉滅火藥劑儲存容器，有關充填比之規定，下列何者正確？",31,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-108-1-water-chemical-028","依法令規定在應設水霧、泡沫、乾粉、二氧化碳滅火設備之場所，但外牆開口面積（常時開放部分）達該層樓地板面積百分之多少以上者，上列滅火設備得採移動式設置？",28,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-108-1-water-chemical-032","依法令規定下列場所何者應設置滅火器？",32,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-108-1-water-chemical-027","依各類場所消防安全設備設置標準之規定，室外消防栓於其 I 公尺範圍內附設水帶箱，在 J 公尺以內，保持空曠，不得堆放物品或種植花木。下列 I，J 何者正確？",27,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-108-1-water-chemical-033","某百貨商場（10 樓以下）內設有一般反應型撒水頭 15 個，試問其消防幫浦最低出水量應為何？",33,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-030",111,"有關消防安全設備檢修完成標示附加位置，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-water-chemical-030",110,"公共危險物品等場所消防設計及消防安全設備，其他滅火困難場所，應設置第幾種滅火設備？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-water-chemical-030",109,"泡沫滅火設備計算之水溶液量，應加算充滿配管所需之泡沫水溶液量，且應加算總泡沫水溶液量之百分之多少？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-030",107,"實施二氧化碳滅火設備檢修，於進行性能檢查時，皮管連接部應無鬆動，皮管損傷、老化等情形，且皮管長度應在幾公尺以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-030",106,"第一種感度之撒水頭其反應時間指數（RTI）應小於多少 (ms) ？",1785123167626]