[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-009":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-009","fire-109-1-alarm-evacuation-009",109,1,9,"有關避難方向指示燈裝設之敘述，下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"可設於地板面，但應具不因荷重而破壞之強度","應裝設於設置場所之走廊、樓梯及通道","轉彎處可以免設","設於可能遭受雨淋之處所者，應具防水構造","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 146-3 條、第 146-4 條關於避難方向指示燈裝設位置與構造的規定。\n【正解理由】第 146-3 條第二項規定，避難方向指示燈應裝設於設置場所之走廊、樓梯及通道，並在各款中把「優先設於轉彎處」列為第一款。轉彎處正是避難者最容易失去方向、發生滯留的位置，條文非但沒有讓它免設，反而列為優先設置點，選項所述與條文相反，故選 C。\n【逐項排除】\n(A) 第 146-4 條第三款規定設於地板面之指示燈應具不因荷重而破壞之強度，敘述正確。\n(B) 第 146-3 條第二項本文即規定應裝設於設置場所之走廊、樓梯及通道，敘述正確。\n(C) 轉彎處為第 146-3 條第二項第一款所定之優先設置位置，並非得以免設，敘述錯誤，為本題應選者。\n(D) 第 146-4 條第四款規定設於可能遭受雨淋或溼氣滯留之處所者，應具防水構造，敘述正確。\n【記憶點】轉彎處是優先設，不是可免設；真正的免設要件寫在第 146 條逐款列舉。","本題四個選項橫跨兩條：第 146-3 條講「設在哪裡」，第 146-4 條講「怎麼設」。第 146-3 條第一項先定出口標示燈的四類位置：通往戶外之出入口、通往直通樓梯之出入口（設有排煙室者為該室出入口）、通往前二款出入口而由室內往走廊或通道之出入口，以及走廊或通道上所設跨防火區劃之防火門；第二項再把避難方向指示燈的三款順序寫明：優先設於轉彎處、設於出口標示燈之有效範圍內、其餘則設在把走廊或通道各部分包含在有效範圍內的必要地點。第 146-4 條則是共通裝設要求：位置不妨礙通行、周圍不得設有影響視線之裝潢及廣告招牌、設於地板面者應具不因荷重而破壞之強度、可能遭受雨淋或溼氣滯留之處所應具防水構造。真正的免設規定在第 146 條，且以步行距離與樓地板面積分級：自居室任一點易於觀察識別其主要出入口者，步行距離在避難層二十公尺以下、其他樓層十公尺以下得免設出口標示燈，避難層四十公尺以下、其他樓層三十公尺以下得免設避難方向指示燈，三十公尺以下得免設避難指標，但位於地下建築物、地下層或無開口樓層者不適用；樓梯或坡道設有緊急照明設備及供確認避難方向之樓層標示者，亦得免設避難方向指示燈。第 146 條第一項第二款另走面積路線：自居室任一點易於觀察識別該居室出入口，且依用途別其居室樓地板面積在一百、二百或四百平方公尺以下者，以及供集合住宅使用之居室，得免設。另第 146-7 條允許在無人期間、可利用自然採光辨識出入口或避難方向等情形下減光或消燈，第 154 條則要求符合出口標示燈及避難方向指示燈認可基準、避難指標構造符合 CNS 一○二○八。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-008","緊急照明燈在地面之水平面照度，使用低照度測定用光電管照度計測得之值，在地下建築物之地下通道，其地板面應在 X 勒克司（Lux）以上，其他場所應在 Y 勒克司（Lux）以上。其中 X， Y 值為何？",8,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-010","緩降機之設置應保有必要操作面積（不含避難器具所占面積），其相關規定下列何者正確？",10,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-007","除火焰式探測器外，一般局限型探測器裝設時，依各類場所消防安全設備設置標準之規定，不得傾斜幾度以上？",7,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-011","避難器具設置數量需衡酌場所之收容人數，依各類場所消防安全設備設置標準規定，百貨商場供飲食或休息用場所之收容人數計算，應以該部分樓地板面積除多少？",11,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-006","差動式局限型探測器進行性能檢查時，使用加熱式試驗器加熱確認動作時間，加熱後到探測器動作應在多少時間以內？",6,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-012","有關緊急電源插座之設置規定，下列敘述何者正確？",12,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-009",110,"瓦斯漏氣火警自動警報設備之性能試驗中，下列有關串接配線試驗之測試及判定，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-009",108,"緩降機固定架或支固器具使用錨定螺栓固定時，選用螺紋標稱為 M12×1.75 之螺栓，試問其螺栓埋入混凝土內不含灰漿部分之深度（mm）及轉矩值須為多少（kgf-cm）？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-009",107,"以下有關各類場所消防安全設備設置標準對火警分區的規定，何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-009",106,"差動式分布型探測器為熱電偶式時，熱電偶應裝置在裝置面下方多少公分範圍內？",1785123171394]