[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-018":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-018","fire-109-1-alarm-evacuation-018",109,1,18,"依住宅用火災警報器認可基準之規定，住宅用火災警報器以警報音發出火災警報，於無響室中距離警報器中心前方 1 公尺處，音壓應有多少分貝以上？",{"A":16,"B":17,"C":18,"D":19},"60","70","80","90","B",null,[],false,"本題考點：住宅用火災警報器認可基準對警報音「音壓」之要求——於無響室中距警報器中心前方一公尺處量測之音壓下限值。\n【正解理由】依住宅用火災警報器認可基準關於音壓之規定，以警報音發出火災警報者，在無響室中距離警報器中心前方一公尺處測得之音壓應在七十分貝以上。本批候選原文僅涵蓋《住宅用火災警報器設置辦法》，未涵蓋該認可基準，故僅引至該基準之音壓要求層級、不另指條號，故選 B。\n【逐項排除】\n(A) 60 分貝低於該基準所定下限，屬一般電子提示音量級，不足以在門扇關閉、就寢狀態下喚醒居住者。\n(B) 70 分貝與認可基準所定之音壓下限相符，為本題應選者。\n(C) 80 分貝高於下限值，產品實測達此值固然合格，但題目問的是基準要求的最低值，非此數。\n(D) 90 分貝同屬高於下限之數值，並非該基準所定之判定門檻。\n【演算步驟】音壓級 L = 20 log₁₀(p \u002F p₀)，基準音壓 p₀ = 2×10⁻⁵ Pa；設一公尺處測得 p = 6.32×10⁻² Pa → L = 20 × log₁₀(6.32×10⁻² Pa ÷ 2×10⁻⁵ Pa) = 20 × log₁₀(3.16×10³) ≈ 20 × 3.5 = 70 dB。\n【記憶點】住警器警報音記「一公尺、七十分貝」。","住宅用火災警報器是《消防法》第 6 條第四項、第五項所定場所的最低限度警報配備，管理權人依《住宅用火災警報器設置辦法》設置並維護。該辦法第 3 條規定安裝位置：寢室、旅館客房或其他供就寢用之居室、廚房、樓梯（有寢室之樓層，但該樓層為避難層者除外；僅避難層有寢室者，為通往上層樓梯之最頂層），以及非屬前三款規定而任一樓層有超過七平方公尺之居室達五間以上者，設於走廊、無走廊者設於樓梯；若已依各類場所消防安全設備設置標準設有自動撒水設備或同等性能以上之滅火設備（限標示溫度在七十五度以下、動作時間在六十秒以內之密閉型撒水頭），在該有效範圍內得免設。第 4 條規定安裝方式：裝於天花板或樓板者，警報器下端距天花板或樓板六十公分以內、並距離牆面或樑六十公分以上；裝於牆面者，距天花板或樓板下方十五公分以上五十公分以下；距離出風口一點五公尺以上；並以裝置於居室中心為原則。第 6 條要求以電池為電源者於達電壓下限發出提示或聲響時更換電池；第 7 條規定使用外部電源者，電源與分電盤間之配線不得設置插座或開關；第 8 條則以有無自動試驗功能區分更換時機。該辦法第 2 條並定明由《消防法》第 6 條第四項、第五項所定場所之管理權人依規定設置並維護，消防機關得依場所之危險程度分類列管檢查及複查，並於依《消防法》第 10 條審查消防安全設備圖說時將住宅用火災警報器納入審查項目。音壓要求之所以訂在無響室距中心前方一公尺七十分貝以上，是因為住警器多裝在寢室天花板，警報須穿透門扇與睡眠狀態；量測選在無響室，是為了排除牆面反射造成的疊加，讓不同廠牌的數據可以直接比較。分貝為對數尺度，音壓級每增加二十分貝代表聲壓放大十倍，故七十與六十分貝之間並非小差距。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-017","一一九火災通報裝置之設置規定，下列敘述何者錯誤？",17,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-019","具閃滅或音聲引導功能之出口標示燈設置規定，下列敘述何者正確？",19,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-016","防煙壁為自天花板下垂 X 公分以上之垂壁，但地下建築物之地下通道，防煙壁應自天花板下垂 Y 公分以上，其中 X、Y 分別為：",16,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-020","B 級出口標示燈且有顯示避難方向符號者，其有效距離係指步行至該燈多少公尺之距離？",20,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-015","有關排煙設備之設置規定，下列敘述何者錯誤？",15,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-021","有關應設置火警自動警報設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",21,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-018",110,"下列避難器具架設完成後，進行綜合檢查時，何者應判定不合格？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-018",108,"利用加瓦斯試驗器對瓦斯漏氣檢知器進行檢測，其性能判定方法下列何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-018",107,"依各類場所消防安全設備設置標準規定，每一火警分區，依規定設置火警發信機，其標示燈應平時保持明亮，其透明罩為圓弧形，裝置後突出牆面，標示燈與裝置面應成幾度角？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-018",106,"依各類場所消防安全設備檢修及申報作業基準規定，火焰探測器以動作試驗器確認探測器之動作應在多少時間內方為合格？",1785123171504]