[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-019":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-019","fire-109-1-alarm-evacuation-019",109,1,19,"具閃滅或音聲引導功能之出口標示燈設置規定，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"設於走廊、轉彎處","由出入口往避難方向所設探測器動作時，該出入口之出口標示燈應立即開始閃滅及音聲引導","不需與火警自動警報設備連動","醫院、療養院主要出入口之出口標示燈應採具閃滅功能或兼具音聲引導功能","D",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 146-5 條，具閃滅或音聲引導功能之出口標示燈的應設場所與連動方式。\n【正解理由】第 146-5 條第一項第三款明定，供第 12 條第一款第六目使用者（即醫院、療養院、長期照顧服務機構等避難弱者場所），其出口標示燈並應採具閃滅功能，或兼具音聲引導功能者，選項敘述與該款一致，故選 D。\n【逐項排除】\n(A) 錯誤，同條第二項第一款明定此類出口標示燈應設於主要出入口；走廊、轉彎處是第 146-3 條第二項所定避難方向指示燈優先設置之位置。\n(B) 錯誤，同條第二項第三款規定，由主要出入口往避難方向所設探測器動作時，該出入口之出口標示燈應「停止」閃滅及音聲引導，而非開始。\n(C) 錯誤，同條第二項第二款明定應與火警自動警報設備連動。\n(D) 正確，即第一項第三款對第 12 條第一款第六目場所所課予之要求，為本題應選者。\n【記憶點】閃滅／音聲出口標示燈三要件：設主要出入口、與火警自動警報設備連動、人已走到門口就停止閃滅與音聲。","第 146-5 條處理的是「看不清楚也要找得到門」的問題。第一項先就三類場所要求出口標示燈及非設於樓梯或坡道之避難方向指示燈應使用 A 級或 B 級，出口標示燈標示面光度應在二十燭光以上或具閃滅功能，避難方向指示燈標示面光度應在二十五燭光以上；但設於走廊而其有效範圍內各部分容易識別該燈者，不在此限。三類場所為：供第 12 條第二款第一目、第三款第三目或第五款第三目使用者；供第 12 條第一款第一目至第五目、第七目或第五款第一目使用而該層樓地板面積在一千平方公尺以上者；以及供第 12 條第一款第六目使用者，後者並須採具閃滅功能或兼具音聲引導功能。第二項的三款要件常被拆開單獨命題：設於主要出入口、與火警自動警報設備連動、由主要出入口往避難方向所設探測器動作時停止閃滅及音聲引導。第三款的「停止」是理解重點——閃滅與語音的功能是把還在室內、看不清方向的人引導到門口；當門口的探測器偵知有人已抵達，繼續閃滅反而干擾通過，故設計為停止。第 146-7 條則規定出口標示燈及避難方向指示燈應保持不熄滅，但與火警自動警報設備之探測器連動亮燈且採適當亮燈方式者，在無人期間、可利用自然採光辨識出入口或避難方向期間、因使用型態特別需要較暗之處所於較暗期間、以及主要供管理權人或其雇用之人等固定使用之處所，得予減光或消燈。閃滅、音聲引導、減光、消燈這四種功能的動作移報裝置，在《各類場所消防安全設備檢修及申報作業基準》標示設備之性能檢查中，係以手動或火警自動警報設備之探測器動作等方法確認其功能，判定要求為燈光閃滅正常、音聲鳴動正常、點燈正常。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-018","依住宅用火災警報器認可基準之規定，住宅用火災警報器以警報音發出火災警報，於無響室中距離警報器中心前方 1 公尺處，音壓應有多少分貝以上？",18,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-020","B 級出口標示燈且有顯示避難方向符號者，其有效距離係指步行至該燈多少公尺之距離？",20,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-017","一一九火災通報裝置之設置規定，下列敘述何者錯誤？",17,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-021","有關應設置火警自動警報設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",21,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-016","防煙壁為自天花板下垂 X 公分以上之垂壁，但地下建築物之地下通道，防煙壁應自天花板下垂 Y 公分以上，其中 X、Y 分別為：",16,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-022","有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X 平方公尺以上，且其中甲類場所樓地板面積合計 Y 平方公尺以上者，應設置瓦斯漏氣火警自動警報設備，下列何者與該設置標準之規定相同？",22,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-019",110,"對於設置在地下建築物、地下層及地上層三者之居室的緊急照明燈進行性能檢查，依照消防安全設備及必要檢修項目檢修基準之規定，使用低照度測定用光電管照度計測試，在地面之水平面照度應分別達多少勒克斯（lux）以上？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-019",108,"應設排煙設備場所之樑為裸露式者，交錯之樑形成之各防煙區劃皆應設置排煙口。但其樓地板面積每 500 平方公尺防煙區劃內，防煙壁及排煙口之設置，符合各類場所消防安全設備設置標準第 188 條第 1 項第 3 款規定，並符合下列何者，不在此限？〔A：大樑深度（cm）；B：中樑深度（cm）；X：大樑下加設之垂壁高度（cm），其值得為 0；A＋X：防煙壁下垂高度（cm）。〕",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-019",107,"在設置避難器具時，皆必須考慮其開口部保有必要開口面積、無操作障礙之面積、下降空間及下降空地等因素，試問於設置避難器具為緩降機時，下列敘述何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-019",106,"一居室設置於地上層，該樓層亦非為無開口樓層，自內部任一點易於識別主要出入口，主要出入口之步行距離在多少以下者，得免設避難方向指示燈？",1785123171509]