[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-020":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-020","fire-109-1-alarm-evacuation-020",109,1,20,"B 級出口標示燈且有顯示避難方向符號者，其有效距離係指步行至該燈多少公尺之距離？",{"A":16,"B":17,"C":18,"D":19},"60","40","30","20","D",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 146-2 條，出口標示燈依級別與有無顯示避難方向符號所對應之有效範圍（步行距離）。\n【正解理由】第 146-2 條明定，出口標示燈及避難方向指示燈之有效範圍，指至該燈之步行距離在該條所列規定步行距離以下之範圍；依第一款附表，出口標示燈 B 級「顯示避難方向符號者」之步行距離為二十公尺，故選 D。\n【逐項排除】\n(A) 60 公尺是同表 A 級「未顯示避難方向符號者」之步行距離，與 B 級無關。\n(B) 40 公尺是同表 A 級「顯示避難方向符號者」之步行距離，級別誤植。\n(C) 30 公尺是同表 B 級「未顯示避難方向符號者」之步行距離，本題已指明顯示避難方向符號，須再降一級距。\n(D) 20 公尺與同表 B 級顯示避難方向符號者之規定相符，為本題應選者。\n【記憶點】出口標示燈 A 級 60／40、B 級 30／20、C 級 15；有顯示避難方向符號就往下退一格。","第 146-2 條除了附表，還給了一條計算式作為第二款的替代認定方式：D＝kh，式中 D 為步行距離（公尺），h 為出口標示燈或避難方向指示燈標示面之縱向尺度（公尺），k 值依區分取用——出口標示燈未顯示避難方向符號者為一百五十、顯示避難方向符號者為一百，避難方向指示燈為五十。以本題的 B 級顯示避難方向符號者為例，若標示面縱向尺度 h 為零點二公尺，代入 D＝kh＝100×0.2＝20 公尺，恰與附表的二十公尺相符，可見表與式其實是同一件事的兩種寫法：標示面愈大、看得愈遠，有方向符號者因為圖示較複雜、辨識所需視角較大，k 值反而下降。另有一個常被忽略的但書：有不易看清或識別該燈之情形者，該有效範圍一律為十公尺。避難方向指示燈的級別對應為 A 級二十公尺、B 級十五公尺、C 級十公尺，數值比出口標示燈小一截，因為它只需把人接力送到下一盞燈。有效範圍的實益在第 146 條與第 23 條：第 23 條規定各類場所均應設置避難指標，但設有避難方向指示燈或出口標示燈時，在其有效範圍內得免設避難指標；第 146 條進一步就自居室任一點易於觀察識別主要出入口者定出免設門檻——步行距離在避難層二十公尺以下、避難層以外樓層十公尺以下得免設出口標示燈，四十公尺與三十公尺以下得免設避難方向指示燈，三十公尺以下得免設避難指標。另依第 154 條，出口標示燈及避難方向指示燈應符合其認可基準，避難指標之構造則應符合 CNS 一○二○八；第 155 條要求緊急電源使用蓄電池設備、容量能有效動作二十分鐘以上，總樓地板面積五萬平方公尺以上等主要避難路徑則須六十分鐘以上。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-019","具閃滅或音聲引導功能之出口標示燈設置規定，下列敘述何者正確？",19,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-021","有關應設置火警自動警報設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",21,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-018","依住宅用火災警報器認可基準之規定，住宅用火災警報器以警報音發出火災警報，於無響室中距離警報器中心前方 1 公尺處，音壓應有多少分貝以上？",18,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-022","有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X 平方公尺以上，且其中甲類場所樓地板面積合計 Y 平方公尺以上者，應設置瓦斯漏氣火警自動警報設備，下列何者與該設置標準之規定相同？",22,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-017","一一九火災通報裝置之設置規定，下列敘述何者錯誤？",17,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-023","有關地下建築物總樓地板面積在幾平方公尺以上應設置無線電通信輔助設備，下列何者與各類場所消防安全設備設置標準之規定相同？",23,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-020",110,"有關辦公大樓排煙設備之啟動裝置在消防安全設備及必要檢修項目檢修基準之性能及綜合檢查的檢查及判定方法，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-020",108,"依消防法令規定，觀光旅館、飯店、旅館、招待所（限有寢室客房者）等場所，採膠囊式經營時，須設置火警自動警報設備者，下列何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-020",107,"依各類場所消防安全設備設置標準規定，瓦斯漏氣警報裝置之檢知器所能檢知瓦斯漏氣之區域內，該檢知器動作時，該區域內之檢知區域警報裝置能發出警報音響，其音壓在距 1 公尺處應有多少分貝以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-020",106,"差動式探測器之動作原理為感應火場中何種參數？",1785123171526]