[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-022":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-022","fire-109-1-alarm-evacuation-022",109,1,22,"有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X 平方公尺以上，且其中甲類場所樓地板面積合計 Y 平方公尺以上者，應設置瓦斯漏氣火警自動警報設備，下列何者與該設置標準之規定相同？",{"A":16,"B":17,"C":18,"D":19},"X=1,000，Y=500","X=1,000，Y=300","X=500，Y=300","X=300，Y=100","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 21 條應設瓦斯漏氣火警自動警報設備之場所，其中複合用途建築物地下層之雙重面積門檻。\n【正解理由】第 21 條第二款明定「供第十二條第五款第一目使用之地下層，樓地板面積合計一千平方公尺以上，且其中甲類場所樓地板面積合計五百平方公尺以上者」，兩項門檻須同時成立，故 X 為 1,000、Y 為 500，故選 A。\n【逐項排除】\n(A) X=1,000、Y=500 與第 21 條第二款所定兩項門檻逐字相符，為本題應選者。\n(B) X 正確但 Y=300 誤植；三百平方公尺是第 19 條第五款火警自動警報設備所定之甲類場所合計門檻，兩者不可互套。\n(C) X=500 不符，第 21 條第二款之地下層樓地板面積合計門檻為一千平方公尺，五百平方公尺是同款的甲類場所門檻。\n(D) X=300、Y=100 兩項數值均非第 21 條所定，屬其他設備之門檻誤植。\n【記憶點】瓦斯漏氣「一千打底、甲類五百」；火警自動警報設備才是「五百打底、甲類三百」。","第 21 條共三款，全部集中在地下：第一款地下層供第 12 條第一款所列場所使用，樓地板面積合計一千平方公尺以上；第二款供第 12 條第五款第一目使用之地下層，樓地板面積合計一千平方公尺以上，且其中甲類場所樓地板面積合計五百平方公尺以上；第三款總樓地板面積在一千平方公尺以上之地下建築物。之所以只管地下，是因為瓦斯外洩後的擴散行為受通風條件支配：地下層無外牆開口、換氣仰賴機械通風，比空氣重的液化石油氣會在低處累積，比空氣輕的天然氣則滯留於天花板下，兩者都難以自然逸散，達到爆炸下限的風險遠高於地上樓層。第 12 條第五款第一目所指的是複合用途建築物中供甲類場所使用者，其定義回到第 4 條第一款：一棟建築物中有供第 12 條第一款至第四款各目所列用途二種以上，且該不同用途在管理及使用形態上未構成從屬於其中一主用途者。設備面的規定則見第 142 條瓦斯漏氣受信總機：裝置於值日室等平時有人之處所，設有防災中心時設於該中心；具有標示瓦斯漏氣發生之警報分區；設於瓦斯導管貫穿牆壁處之檢知器，其警報分區應個別標示；操作開關距樓地板面之高度在零點八公尺以上（座式操作者為零點六公尺）一點五公尺以下；主音響裝置之音色及音壓應有別於其他警報音響；一棟建築物內有二臺以上受信總機時，該受信總機處應設有能相互同時通話連絡之設備。其中「音色及音壓有別於其他警報音響」是為了讓值勤人員一聽就分辨是瓦斯漏氣而非火警，處置方式完全不同。第 238 條並要求防災中心之綜合操作裝置須能監控瓦斯漏氣火警自動警報設備之受信總機。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-021","有關應設置火警自動警報設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",21,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-023","有關地下建築物總樓地板面積在幾平方公尺以上應設置無線電通信輔助設備，下列何者與各類場所消防安全設備設置標準之規定相同？",23,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-020","B 級出口標示燈且有顯示避難方向符號者，其有效距離係指步行至該燈多少公尺之距離？",20,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-024","有關標示設備設在避難出口避難指標之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",24,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-019","具閃滅或音聲引導功能之出口標示燈設置規定，下列敘述何者正確？",19,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-025","有關火焰式探測器之設置，下列何者與各類場所消防安全設備設置標準之規定不同？",25,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-022",110,"有一地下 3 層、地上 7 層之建築物，各層樓地板面積為 600 平方公尺，若地下 1 樓發生火警，則火警自動警報設備之鳴動樓層，下列何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-022",108,"依照各類場所消防安全設備檢修及申報作業基準之規定，會結露之場所適用的探測器為下列何者？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-022",107,"依各類場所消防安全設備設置標準規定，火警自動警報設備之緊急電源，應使用蓄電池設備，其容量能使其有效動作多少分鐘以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-022",106,"依出口標示燈及避難方向指示燈認可基準規定，燈具附有起動器者，應在多少時間內點燈？",1785123171541]