[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-032":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-032","fire-109-1-alarm-evacuation-032",109,1,32,"有關無線電通信輔助設備保護箱標示之外觀檢查的判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"A":16,"B":17,"C":18,"D":19},"保護箱箱面標示有「消防隊專用無線電通信輔助設備」字樣","保護箱箱內明顯易見之位置，應標示有最大容許輸入、可使用之頻率域帶及注意事項","標示應無污損、模糊不清之部分","面板應無剝落之現象","A",null,[],false,"本題考點：無線電通信輔助設備保護箱之標示，關鍵在箱面標示的字樣是「消防隊專用無線電接頭」。\n【正解理由】依《各類場所消防安全設備檢修及申報作業基準》無線電通信輔助設備外觀檢查之保護箱標示判定方法，保護箱箱面應標示有「消防隊專用無線電接頭」字樣，箱內明顯易見之位置應標示有最大容許輸入、可使用之頻率域帶及注意事項，標示應無污損、模糊不清之部分，面板應無剝落之現象。設置端亦相同：《各類場所消防安全設備設置標準》第 192 條第六款明定，接頭裝設於保護箱內，箱內設長度二公尺以上之射頻電纜，保護箱應構造堅固，有防水及防塵措施，其箱面應漆紅色，並標明消防隊專用無線電接頭字樣。選項 A 把箱面字樣寫成「消防隊專用無線電通信輔助設備」，與規定之標示文字不同，故選 A。\n【逐項排除】\n(A) 箱面應標示「消防隊專用無線電接頭」，本項改寫為設備名稱，為本題應選者。\n(B) 與標示判定「箱內明顯易見之位置應標示有最大容許輸入、可使用之頻率域帶及注意事項」相符。\n(C) 與標示判定「標示應無污損、模糊不清之部分」相符。\n(D) 與標示判定「面板應無剝落之現象」相符。\n【記憶點】箱面漆紅色，標的是「接頭」不是「設備」。","本題的分辨點在於標示的對象是「接頭」而非整套設備。無線電通信輔助設備為消防搶救上之必要設備之一，第 11 條列有連結送水管、消防專用蓄水池、排煙設備、緊急電源插座、無線電通信輔助設備五種；其功能是讓消防人員在地下層或大規模地下建築物內仍能以無線電對外通聯，消防人員到場實際要找的是可插接無線電機的接頭，因此箱面標示必須直指接頭所在，而不是寫上設備的全名。\n第 192 條把整套設備的技術規格寫得相當完整，是本設備的核心考點：洩波同軸電纜應適合傳送或輻射一百五十百萬赫或中央主管機關指定之周波數；洩波同軸電纜之標稱阻抗為五十歐姆；電纜應經耐燃處理；分配器、混合器、分波器及其他類似器具，應使用介入衰耗少且接頭部分有適當防水措施者；設增輻器時，其緊急電源應使用蓄電池設備，能量能使其有效動作三十分鐘以上。接頭部分則規定設於地面消防人員便於取用處及值日室等平時有人之處所，設於地面之接頭在任一出入口與其他出入口之步行距離大於三百公尺時應設置二個以上，設於距樓地板面或基地地面高度零點八公尺至一點五公尺間，並裝設於保護箱內、箱內設長度二公尺以上之射頻電纜。\n應設場所依第 30 條為樓高在一百公尺以上建築物之地下層，或總樓地板面積在一千平方公尺以上之地下建築物。檢修上，保護箱之外觀檢查除標示外，另判定周圍應無造成檢查上及使用上之障礙、箱門可確實開關、箱內應無灰塵水份侵入、設置於地面之保護箱需為不可任意開關之構造。把「一百五十百萬赫、五十歐姆、三十分鐘、三百公尺、二公尺射頻電纜、零點八至一點五公尺」串成一組數字，本設備的題目大致都能應付。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-031","有關緊急照明設備性能檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",31,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-033","有關緊急電源插座外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",33,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-030","有關緊急廣播設備標示燈外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準規定相同？",30,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-034","有關排煙設備綜合檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",34,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-029","有關瓦斯漏氣火警自動警報設備檢知器外觀檢查選取之檢查數量，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",29,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-035","有關避難器具開口部周圍狀況外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",35,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-032",110,"下列有關得免設緊急照明設備之處所，何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-032",108,"下列出口標示燈及避難方向指示燈之緊急電源描述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-032",107,"依各類場所消防安全設備設置標準規定，下列何者非屬消防搶救上之必要設備種類？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-032",106,"針對瓦斯漏氣火警自動警報設備進行性能檢查，使用噪音計進行瓦斯漏氣檢知區域警報裝置之音量檢測時，距離警報裝置 1 公尺處，其音壓量應在多少分貝以上方為合格？",1785123171641]