[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-109-1-alarm-evacuation-034":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-警報與避難系統消防安全設備概要-034","fire-109-1-alarm-evacuation-034",109,1,34,"有關排煙設備綜合檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"A":16,"B":17,"C":18,"D":19},"吸煙口及排煙閘門打開後，能連動自動排煙機啟動","醫院等場所，一定要使用緊急電源進行檢查","排煙機在運轉中應無異常聲音及振動，風道應無異常振動","排煙機回轉葉片的回轉方向應正常","B",null,[],false,"本題考點：《各類場所消防安全設備檢修及申報作業基準》排煙設備綜合檢查之判定方法與注意事項，關鍵在醫院等場所的電源例外。\n【正解理由】依該基準排煙設備之綜合檢查，檢查方法係切換成緊急電源之狀態，使偵煙式探測器動作及操作手動啟動裝置，以確認各部分之性能；判定方法為吸煙口及排煙閘門打開後能連動自動排煙機啟動、運轉電流在所規定的範圍內、排煙機在運轉中應無異常聲音及振動且風道應無異常振動、排煙機回轉葉片的回轉方向應正常。注意事項則明定，醫院等切換成緊急電源進行檢查有困難之場所，應使用常用電源進行檢查。選項 B 稱醫院等場所「一定要使用緊急電源進行檢查」，與注意事項所定之例外完全相反，故選 B。\n【逐項排除】\n(A) 為判定方法第一項，吸煙口及排煙閘門打開後能連動自動排煙機啟動，敘述相符。\n(B) 醫院等切換緊急電源有困難之場所應使用常用電源檢查，本項反向敘述，為本題應選者。\n(C) 為判定方法第三項，排煙機在運轉中應無異常聲音及振動，風道應無異常振動。\n(D) 為判定方法第四項，排煙機回轉葉片的回轉方向應正常。\n【記憶點】綜合檢查原則切到緊急電源，醫院等有困難者改用常用電源。","綜合檢查之所以要求切換成緊急電源，是因為火災常伴隨停電，設備必須在緊急電源下仍能完整動作；但醫院設有維生醫療設備，切換電源可能影響病人安全，故基準設有例外，改以常用電源進行檢查。這個例外並非排煙設備獨有：連結送水管之綜合檢查注意事項亦載明，檢查醫院等場所因切換成緊急電源可能會造成困擾時，得使用常用電源進行檢查。「原則緊急電源、醫院等例外」這組體例可整批記憶。\n排煙設備的檢查層次也值得整理。外觀檢查看電動機之控制裝置，包括控制盤之周圍狀況與外形、電壓表、各開關、標示與預備品；性能檢查看各開關端子有無鬆動、保險絲之種類容量、繼電器有無脫落與接點燒損、表示燈、結線接續與接地，並就自動啟動裝置（偵煙式探測器動作後能否連動排煙機啟動）與手動啟動方式（把手應能容易轉動、操作桿應無破損、鋼索應無斷落或生鏽）分別確認，再檢查排煙機電動機之回轉軸、軸承部、動力傳達裝置與本體；到綜合檢查才是整套連動實測。\n設置端的數值可對照《各類場所消防安全設備設置標準》第 188 條：每層樓地板面積每五百平方公尺內以防煙壁區劃，地下建築物之地下通道每三百平方公尺應以防煙壁區劃；防煙區劃範圍內任一位置至排煙口之水平距離在三十公尺以下，排煙口設於天花板或其下方八十公分範圍內；排煙口之開口面積在防煙區劃面積之百分之二以上；排煙機之排煙量在每分鐘一百二十立方公尺以上，一防煙區劃時在該區劃面積每平方公尺每分鐘一立方公尺以上，二區以上時以最大防煙區劃面積每平方公尺每分鐘二立方公尺以上，地下建築物之地下通道總排煙量應在每分鐘六百立方公尺以上；並應連接緊急電源，其供電容量應供其有效動作三十分鐘以上。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-alarm-evacuation-033","有關緊急電源插座外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",33,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-alarm-evacuation-035","有關避難器具開口部周圍狀況外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",35,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-alarm-evacuation-032","有關無線電通信輔助設備保護箱標示之外觀檢查的判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",32,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-alarm-evacuation-036","有關定溫式感知線型探測器之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",36,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-alarm-evacuation-031","有關緊急照明設備性能檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",31,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-alarm-evacuation-037","有關警報系統消防安全設備設置，下列何者與各類場所消防安全設備設置標準之規定不同？",37,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-alarm-evacuation-034",110,"依消防安全設備及必要檢修項目檢修基準，救助袋進行開口部外觀檢查時，開口部面積之限制，下列何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-034",108,"依各類場所消防安全設備設置標準之規定，下列何種避難器具的開口面積應為高 60 公分以上，寬 60 公分以上？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-034",107,"依各類場所消防安全設備檢修及申報作業基準規定，緊急照明設備在建築物總樓地板面積為 5000 平方公尺時，檢查緊急電源容量能否持續 30 分鐘之檢查數量應在多少個以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-034",106,"在裝設定溫式感知線型探測器場所，進行回路合成阻抗試驗時，會使用下列何種檢查儀器？",1785123171656]