[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-fire-law-014":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-消防法規概要-014","fire-109-1-fire-law-014",109,1,14,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，關於可燃性高壓氣體儲存場所構造、設備及安全管理之規定，通路面積至少應占儲存場所面積之百分之多少以上？",{"A":16,"B":17,"C":18,"D":19},"5","10","20","30","C",null,[],false,"本題考點：可燃性高壓氣體儲存場所之安全管理事項中，通路面積應占儲存場所面積的最低比率。\n【正解理由】依《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》第 70 條第七款，可燃性高壓氣體儲存場所之構造、設備及安全管理，明定「通路面積至少應占儲存場所面積之百分之二十以上」。條文用語是「至少」與「以上」，代表這是法定下限而非上限，題目問的正是這個下限值，故選 C。\n【逐項排除】\n(A) 5：第 70 條第七款並無此比率。通路只占二十分之一時，容器搬運動線與人員避難空間都被壓縮，反而會逼出同條第六款所禁止的容器重疊堆放，與條文意旨相違。\n(B) 10：常與同辦法第 72 條「液化石油氣儲存場所僅供一家販賣場所使用之面積，不得少於十平方公尺」互相混淆。一個是絕對面積、一個是面積比率，單位不同，不可代換。\n(C) 20：與第 70 條第七款文字完全相符，為本題正解。條文把它列在灌氣容器與殘氣容器分開直立放置（第六款）之後、周圍二公尺嚴禁煙火（第八款）之前，屬儲存場所內部空間管理的一環。\n(D) 30：留設三成通路雖然仍滿足「百分之二十以上」，但題目問的是法規所定的最低比率，三十並非條文寫出的門檻數值，作為答案即屬錯誤。\n【記憶點】可燃性高壓氣體儲存場所的通路面積「二成打底」——百分之二十以上。","第 70 條是可燃性高壓氣體儲存場所的總則性條文，一次規範構造、設備與安全管理共十三款，考點密度極高，值得整條記熟。構造與設備面：第一款設有警戒標示及防爆型緊急照明設備；第二款設置氣體漏氣自動警報設備；第三款設置防止氣體滯留之有效通風裝置；第四款採不燃材料構造之地面一層建築物，屋頂應以輕質金屬板或其他輕質不燃材料覆蓋，屋簷並應距離地面二點五公尺以上。管理面：第五款保持攝氏四十度以下之溫度，容器並應防止日光直射；第六款灌氣容器與殘氣容器分開儲存、直立放置且不可重疊堆放，並防止翻倒掉落；第七款即本題的通路面積百分之二十以上；第八款周圍二公尺範圍內嚴禁煙火且不得存放任何可燃性物質，但儲存場所牆壁以厚度九公分以上鋼筋混凝土造或具同等以上強度構築防護牆者不在此限；第十二款供二家以上販賣場所使用者，應製作標明面積、數量、編號及商號名稱之平面配置圖並懸掛於明顯處所。\n數值可整理成一串互不重複的口訣：屋簷二點五公尺、溫度四十度、通路二成、周圍二公尺、防護牆九公分。\n就規範邏輯而言，通路比率不是美觀規定，而是搬運與應變需求：液化石油氣鋼瓶多以人力或推車搬運，通路不足會迫使容器堆疊或橫放，正好牴觸第六款；洩漏或起火時，通路也是人員撤離與消防人員接近的唯一路徑。同辦法第 67 條就儲存面積與第一類、第二類保護物訂有安全距離計算式，並於第三項授權中央主管機關另定防爆牆基準，可見本章是用「外部安全距離—牆體防護—內部通路」三層次控制風險，本題問的即是最內層。相關考點還有第 6 條第二項對「可燃性高壓氣體儲存場所即容器儲存室」的定義，以及第 70 條第九款避雷設備應符合 CNS 一二八七二規定。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-fire-law-013","依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，儲存倉庫應為一層建築物，其高度不得超過 6 公尺。但儲存下列何種公共危險物品，且符合相關規定者，其高度得為 20 公尺以下？",13,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-fire-law-015","依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關販賣場所之規定，下列敘述何者正確？",15,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-fire-law-012","依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關於供作六類物品製造場所或一般處理場所使用之建築物，一部分供作室內儲存場所儲存六類物品之數量在管制量 20 倍以下者，其牆壁、樑、柱、地板及上層之地板應為防火構造，且應具有多少小時以上防火時效？",12,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-fire-law-016","依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，一般瓦斯行存放多少公斤以上液化石油氣，應設置漏氣警報器？",16,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-fire-law-011","依各類場所消防安全設備設置標準之規定，下列那一種火警探測器不適合裝設在麵粉廠灰塵會大量滯留的場所？",11,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-fire-law-017","依防火牆及防火水幕設置基準之規定，防火水幕之防護高度在 10 公尺以下時，其每公尺水幕長度放水量應在每分鐘多少公升以上？",17,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-014",111,"下列那一場所不是應設置無線電通信輔助設備之場所？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-fire-law-014",110,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，有關場所之定義，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-fire-law-014",108,"建築物間設有過廊，若符合規定者，則可視為另一場所，下列規定何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-fire-law-014",107,"依各類場所消防安全設備檢修及申報作業基準之規定，滅火器本體上端與樓地板面之距離，若滅火器未滿 18 公斤者應在多少公尺以下？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-014",106,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，有關公共危險物品之儲存及處理，下列何者應避免與水接觸？",1785123158313]