[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-109-1-fire-law-034":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-109-1-消防法規概要-034","fire-109-1-fire-law-034",109,1,34,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，有關幫浦性能之規定，幫浦所消耗之動力，在額定出水量 150%時，其軸動力不得超過馬達額定輸出馬力之多少以下？",{"A":16,"B":17,"C":18,"D":19},"65%","110%","140%","150%","B",null,[],false,"本題考點：消防幫浦性能規定中「軸動力上限」與「全揚程下限」之辨識。\n【正解理由】《各類場所消防安全設備設置標準》第 234 條明定,依本標準設置之室內消防栓、自動撒水等設備,「其消防幫浦、電動機、附屬裝置及配管摩擦損失計算,由中央消防機關另定之」;據此訂定之《消防幫浦加壓送水裝置等及配管摩擦損失計算基準》,就幫浦性能設有兩道方向相反的門檻:出水量放大至額定出水量之 150% 時,全揚程不得低於額定全揚程之 65%(下限),而幫浦此時所消耗之動力,其軸動力不得超過馬達額定輸出馬力之 110%(上限)。題目問的是軸動力,故選 B。\n【逐項排除】\n(A) 65% 是同一組規定裡的「全揚程下限」,對象是揚程不是動力,互換即為典型失分點。\n(B) 110% 正是額定出水量 150% 時軸動力對馬達額定輸出馬力所容許的上限,為本題應選者;留一成餘裕是讓馬達在大流量端不致過載。\n(C) 140% 不是軸動力的容許值;該基準另有以全閉揚程為對象之規定,與本題所問項目不同。\n(D) 150% 是題幹中出水量的放大倍率,把出水量的百分比誤填為軸動力即誤選。\n【演算步驟】軸動力上限＝馬達額定輸出馬力×110%。設馬達額定輸出 10 kW,上限＝10 kW×110%＝11 kW,即出水量達額定值 150% 時軸動力須在 11 kW 以下。\n【記憶點】揚程看 65%、動力看 110%,兩個數字不可對調。","授權體系要先弄清楚,才知道這個 110% 是從哪裡冒出來的。《消防法》第 6 條規定各類場所之管理權人應設置並維護消防安全設備,場所分類及設備設置標準由中央主管機關定之;中央主管機關據此訂定《各類場所消防安全設備設置標準》;《設置標準》第 234 條再往下授權一層,把「消防幫浦、電動機、附屬裝置及配管摩擦損失計算」交由中央消防機關另定,這才有了《消防幫浦加壓送水裝置等及配管摩擦損失計算基準》。所以幫浦的性能數值不在《設置標準》條文裡找得到,考生翻遍《設置標準》也翻不到 110%——這正是命題者要測的層級感。\n\n為什麼要管「額定出水量 150% 時」的軸動力?幫浦的性能曲線是:出水量愈大,全揚程愈低,而軸動力(馬達實際要出的力)愈高。150% 出水量是這條曲線最右端的檢驗點,也是火災時多個放水口同時開啟的最不利狀況。若不對軸動力設上限,馬達會在該點長時間過載,溫升導致絕緣劣化,甚至過載保護跳脫;火場最不能發生的就是幫浦中途停機。訂 110% 而不是 100%,是承認馬達具有短時過載能力,但只給一成餘裕。\n\n單位換算是這一科的基本功:1 kgf\u002Fcm² ≒ 10 公尺水頭 ≒ 0.098 MPa;馬力與功率之間 1 HP ≒ 0.746 kW。題目寫「馬達額定輸出馬力」,實務標示常是 kW,換算後再比對百分比,不要被單位名稱絆住。\n\n數值對照可以這樣記:同一組性能規定,150% 出水量對應「揚程 ≥ 65%」與「軸動力 ≤ 110%」,一個是下限一個是上限,方向相反。相關考點會延伸到《設置標準》裡各設備的幫浦全揚程算式,那才是條文層級寫死的部分:第 37 條室內消防栓 H＝h1＋h2＋h3＋17m、第 42 條室外消防栓 H＝h1＋h2＋h3＋25m、第 58 條自動撒水 H＝h1＋h2＋10m、第 183 條連結送水管中繼幫浦 H＝h1＋h2＋h3＋60m。末項常數(17、25、10、60)才是《設置標準》要背的,幫浦本身的性能百分比則屬基準層級,兩層不要混在一起背。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-109-1-fire-law-033","依各類場所消防安全設備檢修及申報作業基準之規定，各類場所之管理權人應委託檢修專業機構或消防法第 7 條規定之人員辦理檢修，並於檢修完成後多少日內，分別填具消防安全設備檢修申報表及檢附消防安全設備檢修報告書，向當地消防機關申報？",33,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-109-1-fire-law-035","依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，裝設消防撒水幫浦，設計水量為 600 公升\u002F分，其設計揚程為 50 公尺；當揚水量在 900 公升\u002F分時，其揚程需調校在下列何標準值以上，方能判定合格？",35,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-109-1-fire-law-032","依各類場所消防安全設備檢修及申報作業基準，有關滅火器外觀檢查之規定，滅火器本體上端與樓地板面之距離，18 公斤以上者不得超過 a 公尺，未滿 18 公斤者不得超過 b 公尺。a、b 值各為下列何者？",32,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-109-1-fire-law-036","依避難器具支固器具及固定部之結構、強度計算及施工方法之規定，裝置避難器具固定部材料，使用直徑 1 公分錨定螺栓，設定試驗荷重 500 公斤力（kgf）時，則鎖緊扭力應為多少公斤力\u002F公分（kgf\u002Fcm）？",36,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-109-1-fire-law-031","依各類場所消防安全設備設置標準，有關泡沫原液儲存量、泡沫原液與水混合使用濃度之規定，下列敘述何者正確？",31,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-109-1-fire-law-037","依建築技術規則建築設計施工編之定義，每層陽臺面積之和，以不超過建築面積多少為限？其未達 8 平方公尺者，得建築 8 平方公尺。",37,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-034",111,"依消防安全設備及必要檢修項目檢修基準規定，對二氧化碳滅火器進行重量檢查時，如失重超過多少比例以上或壓力表示值在綠色範圍外時，應予以更新，下列何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-fire-law-034",110,"依消防安全設備及必要檢修項目檢修基準規定，室內消防栓設備水帶製造年份超過 10 年應使用耐水壓試驗機，施以 X kgf\u002Fcm2 以上水壓試驗 Y 分鐘合格，始得繼續使用。X＋Y 為多少？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-fire-law-034",108,"依消防法施行細則，有關消防安全設備之設計、監造、裝置及檢修工作項目之規定，下列何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-fire-law-034",107,"依各類場所消防安全設備設置標準之規定，下列何者非屬甲類場所？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-034",106,"各類場所之管理權人應委託檢修專業機構或消防法第 7 條規定之人員辦理檢修，並於檢修完成後幾日內，向當地消防機關申報？",1785123158758]