[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-010":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-010","fire-110-1-alarm-evacuation-010",110,1,10,"各型探測器在性能試驗中，下列有關其動作試驗的動作時間，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"A":16,"B":17,"C":18,"D":19},"定溫式局限型之特種、第一種及第二種，分別在 40 秒、60 秒及 120 秒以內","光電式局限型之特種、第一種及第二種，分別在 30 秒、60 秒及 90 秒以內","火焰式探測器之室內型、室外型及道路型，分別在 30 秒、60 秒及 90 秒以內","非再用型定溫式局限型之特種、第一種及第二種，分別在 40 秒、60 秒及 120 秒以內","C","第10題答Ｂ或Ｃ或BC者均給分",[],false,"本題考點：火警自動警報設備各型探測器動作試驗之動作時間判定值，火焰式探測器不依型別分級。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第十三章火警自動警報設備之性能檢查，以火焰式探測器用動作試驗器之紅外線或紫外線照射時，判定時間為三十秒，再加計蓄積式中繼器或受信機設定之蓄積時間（合計最大二十秒），並未按室內型、室外型、道路型分列三十秒、六十秒、九十秒三級；消防安全設備測試報告書測試方法及判定要領同採單一動作時間。題示分級與規定不同，故選 C。\n【逐項排除】\n(A) 定溫式局限型之特種、第一種、第二種，依表 13-7 之動作時間分別為四十秒、六十秒、一百二十秒，與題示相符。\n(B) 光電式局限型屬偵煙式，依表 13-8 其動作時間分為三十秒、六十秒、九十秒三級，題示之時間數列與規定相符。\n(C) 火焰式探測器之判定時間為單一之三十秒，題示卻按型別遞增為三十、六十、九十秒，與規定不同，為本題應選者。\n(D) 非再用型定溫式局限型依表 13-3 選取檢查數量後，比照再用型進行加熱試驗，動作時間仍為四十秒、六十秒、一百二十秒，與題示相符。\n【記憶點】感熱與偵煙依種別遞增，火焰式一律三十秒。","動作時間的判定不是只看探測器本身，還要把蓄積時間一併計入，這是本章性能檢查最容易被忽略的一層。依第十三章之蓄積性能檢查，對感熱式探測器加熱時，應於表 13-7 所示時間加上蓄積式中繼器或受信總機設定之蓄積時間之合計時間內動作，該合計上限為二十秒；對偵煙式探測器加煙測試時，非蓄積型為表 13-8 所示時間加上設定之蓄積時間，合計上限六十秒，蓄積型則再加上標稱蓄積時間，並另加五秒；火焰式探測器為三十秒加上設定之蓄積時間，合計上限二十秒。另有蓄積性能之中繼器或受信機，使手動報警機動作時，其蓄積性能應自動解除且立即火災表示，這一款常與蓄積時間合併命題。\n檢查數量同樣是級距，不是全部拆檢。定溫式（非再用型）依表 13-3 選取檢查數量：設置數量一以上十以下選一個、十一以上五十以下選二個、五十一以上一百以下選四個、一百零一以上選七個。蓄積性能檢查則依表 13-6，火警分區數五十以下者，感熱式、偵煙式、火焰式各選定一個；五十一以上者各選定二個，且選擇探測器時應輪流選取，並於圖面或檢查表上註記每次選取之位置。\n同一張表還可一併記住：差動式局限型與補償式局限型第一種、第二種之動作時間均為三十秒；定溫式局限型則為特種四十秒、第一種六十秒、第二種一百二十秒。偵煙式的離子式局限型與光電式局限型共用表 13-8，第一種三十秒、第二種六十秒、第三種九十秒。命題手法多半是把某一列的數字挪到另一列，或把只有單一時間的火焰式硬拆成三級，掌握表的形狀即可快速定位。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-009","瓦斯漏氣火警自動警報設備之性能試驗中，下列有關串接配線試驗之測試及判定，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",9,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-011","特別安全梯間與緊急昇降機間兼用之排煙室，如設置排煙管道及進風管道，下列何者在綜合試驗中應判定合格？",11,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-008","下列何組感知線型或分布型探測器在進行外觀試驗時，均須判定其感熱元件之極性有無誤接？",8,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-012","建築物某一樓層（A 區）通往直通樓梯（B 區）的出口標示燈（L）附有誘導音裝置，並設置有停止專用偵煙式探測器（D）及具有緊急廣播設備連動停止性能，在其性能試驗之連動停止試驗中，下列何者應判定不合格？",12,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-007","下列何種火警探測器在認可作業中須進行粉塵試驗？",7,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-013","容易受風影響之場所（如大廳、禮拜堂、大樓頂上之機械室等），依消防安全設備及必要檢修項目檢修基準之規定，可在下列何種探測器中進行選設？",13,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-109-1-alarm-evacuation-010",109,"緩降機之設置應保有必要操作面積（不含避難器具所占面積），其相關規定下列何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-010",108,"某一廣播區域面積為 150 平方公尺，設有揚聲器，請問距所設揚聲器 1 m 處所測得之音壓須達多少以上才符合規定？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-010",107,"依各類場所消防安全設備設置標準第 23 條規定，各類場所均應設置避難指標。但設有以下那一個設備時，在其有效範圍內，得免設置避難指標？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-010",106,"緩降機設置周圍為避免有操作障礙，因此限制必要操作面積為 M 平方公尺以上（不含避難器具所占面積），但邊長應為 N 公分以上。下列何者正確？",1785123170706]