[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-032":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-032","fire-110-1-alarm-evacuation-032",110,1,32,"下列有關得免設緊急照明設備之處所，何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"具有效採光，且直接面向室外之通道或走廊","集合住宅之居室","洗手間、浴室、盥洗室、儲藏室或機械室","幼兒園內之教室","D",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 179 條所列得免設緊急照明設備之六款處所，題目要求挑出不屬該條之敘述。\n【正解理由】第 179 條免設處所僅六款：避難層由居室任一點至通往屋外出口之步行距離在三十公尺以下之居室、具有效採光且直接面向室外之通道或走廊、集合住宅之居室、保齡球館球道以防煙區劃之部分、工作場所中設有固定機械或裝置之部分、洗手間浴室盥洗室儲藏室或機械室。幼兒園教室不在其中，故選 D。\n【逐項排除】\n(A) 逐字對應第 179 條第二款「具有效採光，且直接面向室外之通道或走廊」，屬免設，敘述正確。\n(B) 對應同條第三款「集合住宅之居室」，屬免設，敘述正確。\n(C) 對應同條第六款「洗手間、浴室、盥洗室、儲藏室或機械室」，五者全數列於該款，敘述正確。\n(D) 第 179 條六款並無幼兒園教室；第 24 條規定應設緊急照明設備之處所時，「學校教室除外」之文字僅見於第二款第三目及第三款，並未替幼兒園教室開免設之門，故本項錯誤。\n【記憶點】免設緊急照明只認第 179 條六款，條文裡的除外對象是學校教室，不是幼兒園教室。","緊急照明設備的規範分成「應設」與「免設」兩面。應設在《各類場所消防安全設備設置標準》第 24 條，共五款：供第十二條第一款、第三款及第五款所列場所使用之居室；供第十二條第二款第一目、第二目、第三目（學校教室除外）、第四目至第六目、第七目所定住宿型精神復健機構、第八目、第九目及第十二目所列場所使用之居室；總樓地板面積在一千平方公尺以上建築物之居室（學校教室除外）；有效採光面積未達該居室樓地板面積百分之五者；以及供前四款使用之場所，自居室通達避難層所須經過之走廊、樓梯間、通道及其他平時依賴人工照明部分。該條末項並定有經中央主管機關認可為容易避難逃生或具有效採光之場所得免設之概括規定。\n免設在第 179 條，共六款，本題四個選項有三個直接取自其中。六款可用「有光、有人管、用不到」三類記：有光的是第一款在避難層由居室任一點至通往屋外出口之步行距離在三十公尺以下之居室，以及第二款具有效採光且直接面向室外之通道或走廊；有人管的是第三款集合住宅之居室；用不到的是第四款保齡球館球道以防煙區劃之部分、第五款工作場所中設有固定機械或裝置之部分、第六款洗手間、浴室、盥洗室、儲藏室或機械室。\n配套規定同樣常考。第 176 條規定緊急照明設備除內置蓄電池式外，照明器具應直接連接於分路配線，不得裝置插座或開關等；緊急照明燈之電源回路依第二百三十五條規定施予耐燃保護，但天花板及其底材使用不燃材料時，得施予耐熱保護。第 177 條規定緊急照明設備應連接緊急電源，該緊急電源應使用蓄電池設備，容量應能使其持續動作三十分鐘以上；採蓄電池設備與緊急發電機併設方式時，容量應能使其持續動作分別為十分鐘及三十分鐘以上。應設、免設、配線、電源四段合起來，就是這一設備的完整考點地圖。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-031","一一九火災通報裝置，下列規定何者正確？",31,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-033","緩降機在進行綜合檢查之下降試驗時，以測量下降距離及下降時間計算出下降速度，平均下降速度何者正確？",33,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-030","火警自動警報設備之緊急電源，其容量能使其有效動作 A 分鐘以上；緊急廣播設備之緊急電源，其容量能使其有效動作 B 分鐘以上，其中 A 及 B 分別為：",30,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-034","依消防安全設備及必要檢修項目檢修基準，救助袋進行開口部外觀檢查時，開口部面積之限制，下列何者正確？",34,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-029","有關瓦斯漏氣檢知器之設置，當瓦斯對空氣之比重小於 1 時，應設於距瓦斯燃燒器具水平距離 A 公尺以內；當瓦斯對空氣之比重大於 1 時，應設於距瓦斯燃燒器具水平距離 B 公尺以內，其中 A 及 B 分別為：",29,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-035","依各類場所消防安全設備設置標準規定，避難指標設於走廊或通道時，自走廊或通道任一點至指標之步行距離在多少公尺以下？",35,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-109-1-alarm-evacuation-032",109,"有關無線電通信輔助設備保護箱標示之外觀檢查的判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-032",108,"下列出口標示燈及避難方向指示燈之緊急電源描述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-032",107,"依各類場所消防安全設備設置標準規定，下列何者非屬消防搶救上之必要設備種類？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-032",106,"針對瓦斯漏氣火警自動警報設備進行性能檢查，使用噪音計進行瓦斯漏氣檢知區域警報裝置之音量檢測時，距離警報裝置 1 公尺處，其音壓量應在多少分貝以上方為合格？",1785123170950]