[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-110-1-alarm-evacuation-037":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-警報與避難系統消防安全設備概要-037","fire-110-1-alarm-evacuation-037",110,1,37,"下列有關緊急電源插座之設置，何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"緊急電源插座裝設於樓梯間或緊急昇降機間等消防人員易於施行救火處","緊急電源插座為接地型，裝設高度距離樓地板 1 公尺以上 1.5 公尺以下","應從主配電盤設專用回路，各層至少設 2 回路以上之供電線路","各插座設容量 110 伏特、15 安培以上之漏電斷路器","D",null,[],false,"本題考點：緊急電源插座之設置規定，見《各類場所消防安全設備設置標準》第 191 條所列九款。\n【正解理由】第 191 條第八款明定「各插座設容量一百一十伏特、十五安培以上之無熔絲斷路器」，同條第七款並規定該專用回路「不得設漏電斷路器」；選項把無熔絲斷路器寫成漏電斷路器，與這兩款同時牴觸，為錯誤敘述，故選 D。\n【逐項排除】\n(A) 對應第一款，緊急電源插座裝設於樓梯間或緊急昇降機間等消防人員易於施行救火處，該款並要求每一層任何一處至插座之水平距離在五十公尺以下，敘述正確。\n(B) 對應第四款，緊急電源插座為接地型，裝設高度距離樓地板一公尺以上一點五公尺以下，敘述正確。\n(C) 對應第六款，應從主配電盤設專用回路，各層至少設二回路以上之供電線路，該款並限制每一回路之連接插座數在十個以下，敘述正確。\n(D) 斷路器種類寫錯，條文要求的是無熔絲斷路器，且第七款明文專用回路不得設漏電斷路器，為本題應選者。\n【記憶點】緊急電源插座：一百一十伏特十五安培配無熔絲斷路器，專用回路不准裝漏電斷路器。","緊急電源插座屬《各類場所消防安全設備設置標準》第 11 條所列「消防搶救上之必要設備」，同列的還有連結送水管、消防專用蓄水池、排煙設備、無線電通信輔助設備及防災監控系統綜合操作裝置。這一類設備服務的對象是到場搶救的消防人員而非場所使用人，掌握這點就容易理解它為什麼設在樓梯間與緊急昇降機間。應設場所見第 29 條三款：十一層以上建築物之各樓層、總樓地板面積在一千平方公尺以上之地下建築物、依建築技術規則應設置之緊急昇降機間。\n第 191 條九款可分四組整理。位置與距離：第一款裝設於樓梯間或緊急昇降機間等（含各該處五公尺以內之場所）消防人員易於施行救火處，且每一層任何一處至插座之水平距離在五十公尺以下；第四款前段規定為接地型，裝設高度距離樓地板一公尺以上一點五公尺以下。電氣容量：第二款電流供應容量為交流單相一百一十伏特（或一百二十伏特）十五安培，容量約為一點五瓩以上；第八款各插座設容量一百一十伏特、十五安培以上之無熔絲斷路器。回路：第六款應從主配電盤設專用回路，各層至少設二回路以上之供電線路，且每一回路之連接插座數在十個以下，每回路電線容量在二個插座同時使用之容量以上；第七款該專用回路不得設漏電斷路器；第九款緊急用電源插座連接至緊急供電系統。保護箱：第四款後段要求裝設二個於崁裝式保護箱，保護箱長邊及短邊分別為二十五公分及二十公分以上，為厚度在一點六毫米以上之鋼板或具同等性能以上之不燃材料製，箱內有防止插頭脫落之Ｌ型或Ｃ型護鉤，箱蓋為易於開閉之構造並標示緊急電源插座字樣每字在二平方公分以上，且須接地；與室內消防栓箱等併設時，須設於上方且保護箱蓋須能另外開啟。第五款則要求在保護箱上方設紅色表示燈。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-alarm-evacuation-036","某場所第五層需設置排煙設備，樓地板面積為 1200 平方公尺並區分為 450、400 及 350 平方公尺等三個防煙區劃，試問該層排煙機之排煙量最少應為每分鐘多少立方公尺？",36,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-alarm-evacuation-038","特別安全梯排煙室設置直接面向戶外之窗戶時，窗戶之有效開口面積應在多少平方公尺以上？",38,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-alarm-evacuation-035","依各類場所消防安全設備設置標準規定，避難指標設於走廊或通道時，自走廊或通道任一點至指標之步行距離在多少公尺以下？",35,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-alarm-evacuation-039","依消防安全設備及必要檢修項目檢修基準，火焰式探測器進行性能檢查時，使用火焰探測器用動作試驗器，探測器應在多少時間內動作？",39,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-alarm-evacuation-034","依消防安全設備及必要檢修項目檢修基準，救助袋進行開口部外觀檢查時，開口部面積之限制，下列何者正確？",34,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-alarm-evacuation-040","避難器具之裝設規定，下列何者正確？",40,[53,57,61,65],{"webId":54,"year":55,"stem":56,"number":13},"fire-109-1-alarm-evacuation-037",109,"有關警報系統消防安全設備設置，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":58,"year":59,"stem":60,"number":13},"fire-108-1-alarm-evacuation-037",108,"某機場候機室樓地板面積 300 m2，自然排煙設備其窗戶都在天花板或其下方 80 公分範圍內，共有 10 扇窗，採正向由上往外推可達 90°，請問每一扇窗面積多大才合格？",{"webId":62,"year":63,"stem":64,"number":13},"fire-107-1-alarm-evacuation-037",107,"設置避難器具時，標示其設置位置、使用方法並設置指標，下列規定何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-106-1-alarm-evacuation-037",106,"為避免探測死角，在安裝光電式分離型探測器時，其受光器及送光器應設在距其背部牆壁多少公分範圍內？",1785123171012]