[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-110-1-fire-law-001":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":26,"sameNumber":52,"hasEssay":25},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":12,"stem":13,"options":14,"answer":19,"answerNote":20,"images":21,"imagesPending":22,"lawTimestamp":11,"explanation":23,"explanationDeep":24,"freq":12,"indexable":25},"fire-110-1-消防法規概要-001","fire-110-1-fire-law-001",110,1,"工廠發生火災時，工廠之管理權人雖指派專人至現場協助救災，但未能提供廠區化學品種類、數量、位置平面配置圖及搶救必要資訊供消防人員參考。依消防法規定，該處管理權人多少罰鍰？",{"A":15,"B":16,"C":17,"D":18},"新臺幣 2 萬元以上 10 萬元以下","新臺幣 3 萬元以上 15 萬元以下","新臺幣 3 萬元以上 60 萬元以下","新臺幣 50 萬元以上 150 萬元以下","C",null,[],false,"本題考點：《消防法》第 21-1 條課予工廠管理權人的兩款義務，以及第 43-1 條就兩款義務分設的兩種罰鍰級距。\n【正解理由】第 21-1 條規定，消防指揮人員搶救工廠火災時，工廠之管理權人應依下列規定辦理：「一、提供廠區化學品種類、數量、位置平面配置圖及搶救必要資訊。二、指派專人至現場協助救災。」第 43-1 條第一項則明定，違反第 21-1 條第一款規定，工廠之管理權人未提供廠區化學品種類、數量、位置平面配置圖及搶救必要資訊，或提供資訊內容虛偽不實者，處管理權人「新臺幣三萬元以上六十萬元以下罰鍰」。題示情形已指派專人到場，欠缺的只是資訊提供，適用第一款之罰則，故選 C。\n【逐項排除】\n(A) 二萬元以上十萬元以下，是第 39 條、第 42 條與第 38 條第三項所用之級距，非本題情形。\n(B) 三萬元以上十五萬元以下，是第 38 條第一項及第 41-1 條第一項之級距。\n(C) 三萬元以上六十萬元以下，正是第 43-1 條第一項未提供搶救必要資訊之罰鍰，為本題應選者。\n(D) 五十萬元以上一百五十萬元以下，係第 43-1 條第二項未指派專人到場協助救災之罰鍰，題示已指派專人，不適用。\n【記憶點】工廠火災兩義務兩罰則：「不給資訊 3～60 萬、不派人 50～150 萬」。","第 21-1 條與第 43-1 條是一組義務條與罰則條，兩款義務對應兩項罰鍰，且罰鍰高低刻意拉開。未提供資訊為三萬元以上六十萬元以下，未指派專人到場則是五十萬元以上一百五十萬元以下，後者的下限甚至高於前者的上限。條文如此設計，是因為現場有沒有熟悉廠區的人可供詢問，直接決定搶救部署的安全性；化學品資訊則影響滅火藥劑選擇與警戒範圍，兩者都屬於指揮人員無從自行取得的資訊。\n把《消防法》的罰則體系橫向排開，更容易記住級距的落點：第 37 條第一項就消防安全設備、住宅用火災警報器及防焰物品之違規，經通知限期改善逾期不改者，處管理權人六千元以上三萬元以下罰鍰，並得連續處罰及三十日以下停業或停止使用；同條第二項規避、妨礙或拒絕檢查複查者，三千元以上一萬五千元以下並按次處罰。第 38 條第一項違反第 7 條第一項擅自從事消防安全設備設計、監造、裝置或檢修者，三萬元以上十五萬元以下並得按次處罰；第三項則就檢修專業機構、消防設備師或消防設備士未依規定檢修或為不實檢修報告者，二萬元以上十萬元以下並得按次處罰，必要時得處一個月以上一年以下停止執行業務或停業。第 40 條違反第 13 條防火管理規定經通知限期改善逾期不改者，一萬元以上五萬元以下。第 41-1 條第一項違反明火表演相關辦法者，三萬元以上十五萬元以下並得按次處罰。第 42 條公共危險物品場所位置構造設備不符或儲存處理搬運違反安全管理規定者，二萬元以上十萬元以下。\n刑罰部分另成一格：第 34 條毀損供消防使用之蓄、供水設備或消防、救護設備者，處三年以下有期徒刑或拘役，得併科六千元以上三萬元以下罰金，未遂犯罰之；第 35 條應設消防安全設備之供營業使用場所或應設住宅用火災警報器之場所，管理權人未依規定設置或維護，於發生火災時致人於死者，處一年以上七年以下有期徒刑，得併科一百萬元以上五百萬元以下罰金，致重傷者減等。可見同樣是管理權人，罰鍰與刑罰的分水嶺在於有無實害發生。",true,[27,32,36,40,44,48],{"webId":28,"stem":29,"number":30,"year":31,"session":12},"fire-109-1-fire-law-040","依建築技術規則建築設計施工編之規定，閣樓樓地板面積占該建築物建築面積多少以上時，視為另一樓層？",40,109,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-law-002","明火表演，指以產生火焰、火花或火星等方式之表演活動，下列敘述何者正確？",2,{"webId":37,"stem":38,"number":39,"year":31,"session":12},"fire-109-1-fire-law-039","依各類場所消防安全設備設置標準之規定，以防護區域每平方公尺每分鐘放水量來看，儲存可燃物場所設置放水型撒水頭是一般場所要求的幾倍？",39,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-fire-law-003","依消防法規定，下列敘述何者正確？",3,{"webId":45,"stem":46,"number":47,"year":31,"session":12},"fire-109-1-fire-law-038","依建築技術規則建築設計施工編之定義，經主管機關認可後，下列何者屬「防火設備」？",38,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-fire-law-004","某 KTV 之管理權人未依規定維護該場所之消防安全設備，導致火災發生時，消防安全設備無法發揮正常功能，而造成二名消費者死亡，依消防法之規定，對管理權人之處分，下列敘述何者正確？",4,[53,57,61,64,68],{"webId":54,"year":55,"stem":56,"number":12},"fire-115-1-fire-law-001",115,"依消防法規定，下列何者應委託中央主管機關許可之消防安全設備檢修專業機構辦理檢修申報？ ①複合用途建築物 ②地下建築物 ③高層建築物 ④大型集合住宅",{"webId":58,"year":59,"stem":60,"number":12},"fire-111-1-fire-law-001",111,"依消防法及消防法施行細則之規定，下列那一個場所應由管理權人，遴用防火管理人並責其製定消防防護計畫報請消防機關核備？",{"webId":62,"year":31,"stem":63,"number":12},"fire-109-1-fire-law-001","依消防法、消防法施行細則之規定，有關一定規模以上供公眾使用建築物，下列敘述何者正確？",{"webId":65,"year":66,"stem":67,"number":12},"fire-108-1-fire-law-001",108,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，容器串接使用場所串接使用量在 80 公斤以上未滿 120 公斤者，其安全設施之規定下列何者錯誤？",{"webId":69,"year":70,"stem":71,"number":12},"fire-107-1-fire-law-001",107,"依消防法之規定，液化石油氣零售業者應備置資料，定期向轄區消防機關申報，並保存多久，以備查核？",1785123157716]