[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-fire-law-021":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-消防法規概要-021","fire-110-1-fire-law-021",110,1,21,"依各類場所消防安全設備設置標準規定，有關應設置自動撒水設備之場所，其撒水頭之位置規定，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"撒水頭迴水板下方 30 公分內及水平方向 45 公分內，應保持淨空間，不得有障礙物","密閉式撒水頭之迴水板裝設於裝置面（指樓板或天花板）下方，其間距在 30 公分以下","使用密閉式撒水頭，且風管等障礙物之寬度超過 110 公分時，該風管等障礙物下方，亦應設置","側壁型撒水頭迴水板下方及水平方向 30 公分內，保持淨空間，不得有障礙物","B",null,[],false,"本題考點：撒水頭裝置位置的淨空間距離、迴水板與裝置面的間距、風管等障礙物的寬度門檻與側壁型的淨空間。\n【正解理由】依《各類場所消防安全設備設置標準》第 47 條第三款，「密閉式撒水頭之迴水板裝設於裝置面（指樓板或天花板）下方，其間距在三十公分以下」，(B) 與條文完全相同，故選 B。\n【逐項排除】\n(A) 同條第二款為「撒水頭迴水板下方四十五公分內及水平方向三十公分內，應保持淨空間」，本項把四十五與三十對調，垂直與水平方向的數值都放錯位置。\n(B) 迴水板裝設於裝置面下方、間距三十公分以下，與第 47 條第三款一致，正確。\n(C) 同條第六款的門檻是風管等障礙物寬度「超過一百二十公分」時，該障礙物下方亦應設置撒水頭，本項寫一百一十公分，門檻錯誤。\n(D) 同條第七款第三目規定側壁型撒水頭「迴水板下方及水平方向四十五公分內，保持淨空間」，本項寫三十公分，淨空間不足。\n【記憶點】一般型上下 45、水平 30；側壁型上下與水平都是 45；風管超過 120 公分才要在下方補設。","撒水頭的淨空間規定是為確保撒水分布不被遮擋，方向不同、數值也不同，命題者最愛把兩個數字對調。除第 47 條第二、三款外，同條第四款規定密閉式撒水頭裝置於樑下時，迴水板與樑底之間距在十公分以下，且與樓板或天花板之間距在五十公分以下；第五款規定裝置面四周以淨高四十公分以上之樑或類似構造體區劃包圍時，按各區劃裝置，但該樑之間距在一百八十公分以下者不在此限。第七款另定側壁型撒水頭與牆壁之間距、迴水板與天花板之間距均在十五公分以下。\n同條第八款有密閉式撒水頭側面有樑時的對照表：撒水頭與樑側面淨距離七十四公分以下時，迴水板高出樑底面為零；七十五至九十九公分為九公分以下；一百至一百四十九公分為十四公分以下；一百五十公分以上為二十九公分以下。迴水板與天花板或樓板距離超過三十公分時，另依同條第二項設置直徑三十公分以上之金屬防護板，且防護板與迴水板距離在三十公分以下。\n「位置」與「配置」是兩個層次，答題前先辨明題目問哪一個：配置屬第 46 條，舞臺、放映室、易燃物品倉庫為一點七公尺以下，一般反應型二點一公尺（防火構造二點三公尺），快速反應型二點三公尺（防火構造二點六公尺），小區劃型二點六公尺且撒水頭間距三公尺以上、防護面積十三平方公尺以下，側壁型牆面二側一點八公尺、牆壁前方三點六公尺。至於公共危險物品等場所另有第四編第 211 條，存放易燃性物質處所的淨空間為迴水板下方九十公分及水平方向三十公分以內，與一般場所不得互套。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-fire-law-020","依法應裝設火警自動警報設備之建築物，其裝設受信總機及探測器等相關規定，下列敘述何者正確？",20,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-law-022","依各類場所消防安全設備設置標準規定，避難器具於開口部與地面之間保有必要下降空間，下列敘述何者正確？",22,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-fire-law-019","有一棟建築物高度超過 60 公尺，其連結送水管採用濕式設計，並設中繼幫浦，下列敘述何者正確？",19,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-fire-law-023","依各類場所消防安全設備設置標準規定，下列何者屬應設置室內消防栓設備的場所？",23,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-fire-law-018","第一種室內消防栓與室外消防栓之比較，下列敘述何者正確？",18,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-fire-law-024","依各類場所消防安全設備設置標準規定，有關連結送水管之送水設計壓力規定計算，下列敘述何者錯誤？",24,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-021",111,"依建築技術規則建築設計施工編所訂之建築技術用語，下列何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-fire-law-021",109,"依各類場所消防安全設備設置標準，有關使用密閉式撒水頭自動撒水設備末端查驗閥之規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-fire-law-021",108,"依消防安全設備檢修專業機構管理辦法規定，對「檢修機構」的描述，下列何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-fire-law-021",107,"依消防法之規定，下列何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-021",106,"下列有關消防法施行細則第 14 條防火管理人規定之敘述，何者錯誤？",1785123157944]