[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-fire-law-023":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-消防法規概要-023","fire-110-1-fire-law-023",110,1,23,"依各類場所消防安全設備設置標準規定，下列何者屬應設置室內消防栓設備的場所？",{"A":16,"B":17,"C":18,"D":19},"四層建築物，每層樓面積 200 平方公尺，一樓經營指壓按摩場所","三層建築物，每層樓面積 350 平方公尺，一樓經營遊藝場所","七層建築物，每層樓面積 200 平方公尺，二樓經營理容院","設於地下層之撞球場，樓地板面積 120 平方公尺","C",null,[],false,"本題考點：應設室內消防栓設備場所的判斷，必須同時看樓層數、第 12 條的用途目次與各層樓地板面積門檻。\n【正解理由】依《各類場所消防安全設備設置標準》第 15 條第一項第二款，「六層以上建築物，供第十二條第一款至第四款所列場所使用，任何一層之樓地板面積在一百五十平方公尺以上者」應設室內消防栓設備。(C) 為七層建築物，理容院依第 12 條第一款第一目屬甲類場所，每層二百平方公尺已逾一百五十平方公尺，故選 C。\n【逐項排除】\n(A) 四層屬五層以下，指壓按摩場所為第 12 條第一款第一目，適用第 15 條第一項第一款的三百平方公尺門檻，每層二百平方公尺未達，不必設置。\n(B) 三層同屬五層以下，遊藝場所為第 12 條第一款第二目，屬條文所稱「第一款其他各目」，門檻為五百平方公尺，每層三百五十平方公尺未達。\n(C) 七層已達六層以上，門檻降為一百五十平方公尺，每層二百平方公尺超過門檻，應設置。\n(D) 撞球場為第 12 條第一款第二目，設於地下層適用第 15 條第一項第四款「其他各目」之一百五十平方公尺門檻，本項僅一百二十平方公尺，未達。\n【記憶點】五層以下看 300 與 500，六層以上一律 150，地下層看 100 與 150。","第 15 條的門檻是三段式的：五層以下建築物依用途分級，甲類第一目三百平方公尺、第一款其他各目及第二款至第四款五百平方公尺、學校教室一千四百平方公尺；六層以上建築物不分用途一律一百五十平方公尺；地下層或無開口樓層則為一百平方公尺（第一款第一目）與一百五十平方公尺（其他）。樓層越高、開口越少，搶救越困難，門檻就越低，這個梯度就是判斷順序：先看樓層、再看用途目次、最後比面積。\n用途歸類必須回到第 12 條逐目對照。理容院（觀光理髮、視聽理容等）與指壓按摩場所同列第一款第一目，撞球場、遊藝場所、電子遊戲場、資訊休閒場所則在第一款第二目；兩目在五層以下的門檻相差將近一倍，選項常刻意把兩者混放來製造誘答。\n第 15 條第二項另有免設規定：依本標準設有自動撒水（含補助撒水栓）、水霧、泡沫、二氧化碳、乾粉或室外消防栓等滅火設備者，在該有效範圍內得免設室內消防栓設備；設有室外消防栓設備時，在第一層水平距離四十公尺以下、第二層步行距離四十公尺以下之有效滅火範圍內，僅第一層與第二層免設。與此相對，第 16 條的室外消防栓以危險工作場所分級（高度危險三千、中度危險五千、低度危險一萬平方公尺），並有比例總合大於一的合併計算方式。最後要避免與《消防法施行細則》第 13 條的「一定規模以上供公眾使用建築物」清單混淆，那是另一套判斷對象，不是消防安全設備的設置門檻。橫向再看門檻的落差會更有感：第 14 條的滅火器對甲類場所、地下建築物、幼兒園一律要設，乙丙丁類場所總樓地板面積一百五十平方公尺以上才設，地下層或無開口樓層則以五十平方公尺為界；室內消防栓的門檻明顯高得多，因為它是需要人員操作的水系統。另外第 13 條規定增建、改建或變更用途時原則適用變更前之標準，但用途變更為甲類場所使用時，該變更後用途之消防安全設備即適用新標準，這一款常與應設場所題合併出現。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-fire-law-022","依各類場所消防安全設備設置標準規定，避難器具於開口部與地面之間保有必要下降空間，下列敘述何者正確？",22,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-law-024","依各類場所消防安全設備設置標準規定，有關連結送水管之送水設計壓力規定計算，下列敘述何者錯誤？",24,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-fire-law-021","依各類場所消防安全設備設置標準規定，有關應設置自動撒水設備之場所，其撒水頭之位置規定，下列敘述何者正確？",21,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-fire-law-025","某場所室內高度為 16 公尺，依各類場所消防安全設備設置標準規定，下列何者為可選擇之探測器種類？①定溫式特種 ②差動式分布型 ③光電式局限型一種 ④火焰式",25,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-fire-law-020","依法應裝設火警自動警報設備之建築物，其裝設受信總機及探測器等相關規定，下列敘述何者正確？",20,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-fire-law-026","依各類場所消防安全設備設置標準規定，裝設火警自動警報設備之建築物，其火警分區劃定，下列敘述何者正確？",26,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-023",111,"消防安全設備檢修專業機構於證書有效期間內，進行證書記載事項變更時，檢修機構應自事實發生之日起多久期間內，依收費標準繳納證書費，並檢具申請書及變更事項證明文件，向中央主管機關申請換發證書？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-fire-law-023",109,"依各類場所消防安全設備設置標準，有關一一九火災通報裝置設置之規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-fire-law-023",108,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，下列有關「擋牆」之敘述，何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-fire-law-023",107,"依消防法施行細則之規定，防火管理人應為管理或監督層次人員，並經中央消防機關認可之訓練機構或直轄市、縣（市）消防機關講習訓練合格領有證書始得充任。其講習訓練時數，初訓不得少於 X 小時；複訓不得少於 Y 小時，X、Y 分別為多少？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-023",106,"下列有關消防設備師及消防設備士管理辦法規定之敘述，何者錯誤？",1785123157971]